References
- Ying YL, Lin JW, Oghalai JS, et al. Cochlear implant electrode misplacement: incidence, evaluation, and management. Laryngoscope. 2013;123(3):757–766.
- Zuniga MG, Rivas A, Hedley-Williams A, et al. Tip fold-over in cochlear implantation: case series. Otol Neurotol. 2017;38(2):199–206.
- Holden LK, Finley CC, Firszt JB, et al. Factors affecting open-set word recognition in adults with cochlear implants. Ear Hear. 2013;34(3):342–360.
- Wang J, Dawant BM, Labadie RF, et al. Retrospective evaluation of a technique for patient-customized placement of precurved cochlear implant electrode arrays. Otolaryngol Head Neck Surg. 2017;157(1):107–112.
- Aschendorff A, Kubalek R, Bink A, et al. Rotational tomography in cochlear implant patients: a new tool for quality control of the electrode position. Cochlear Implants Int. 2004;5(S1):147–149. Suppl 1.
- Wanna GB, Noble JH, McRackan TR, et al. Assessment of electrode placement and audiological outcomes in bilateral cochlear implantation. Otol Neurotol. 2011;32(3):428–432.
- Jia H, Torres R, Nguyen Y, et al. Intraoperative conebeam CT for assessment of intracochlear positioning of electrode arrays in adult recipients of cochlear implants. Am J Neuroradiol. 2018;39(4):768–774.
- Noble JH, Labadie RF, Majdani O, et al. Automatic segmentation of intra-cochlear anatomy in conventional CT. IEEE Trans Biomed Eng. 2011;58(9):2625–2632.
- Zhao Y, Dawant BM, Labadie RF, et al. Automatic localization of cochlear implant electrodes in CT. Med Image Comput Comput Assist Interv. 2014;17(Pt 1):331–338.
- Noble JH, Dawant BM. Automatic graph-based localization of cochlear implant electrodes in CT. Med Image Comput Comput Assist Interv. 2015;9350:152–159.
- Labadie RF, Balachandran R, Noble JH, et al. Minimally invasive image-guided cochlear implantation surgery: first report of clinical implementation. Laryngoscope. 2014;124(8):1915–1922.
- Dhanasingh A, Jolly C. Review on cochlear implant electrode array tip fold-over and scalar deviation. J Otol. 2019;14(3):94–100.
- Aschendorff A, Briggs R, Brademann G, et al. Clinical investigation of the nucleus slim modiolar electrode. Audiol Neurotol. 2017;22(3):169–179.
- Morrel SG, Manzoor NF, Nassiri AM, et al. Precurved electrode insertion techniques affect final electrode position in temporal bones. Poster session presented at: 152nd Annual Meeting of the American Otological Society; 2019 May 3–4; Austin, TX.
- Riemann C, Sudhoff H, Todt I. The pull-back technique for the 532 slim modiolar electrode. Biomed Res Int. 2019;2019:6917084.
- Balachandran R, Schurzig D, Fitzpatrick JM, et al. Evaluation of portable CT scanners for otologic image-guided surgery. Int J Cars. 2012;7(2):315–321.
- Yu L, Vrieze TJ, Bruesewitz MR, et al. Dose and image quality evaluation of a dedicated cone-beam CT system for high-contrast neurologic applications. Am J Roentgenol. 2010;194(2):W193–W201.
- Childers CP, Maggard-Gibbons M. Understanding costs of care in the operating room. JAMA Surg. 2018;153(4):e176233.
- Chakravorti S, Noble JH, Gifford RH, et al. Further evidence of the relationship between cochlear implant electrode positioning and hearing outcomes. Otol Neurotol. 2019;40(5):617–624.
- Holder JT, Kessler D, Noble J, et al. Prevalence of extracochlear electrodes: computerized tomography scans, cochlear implant maps, and operative reports. Otol Neurotol. 2018;39(5):e325–e331.