- Apuzzo MLJ, Sabshin JK. Computed tomographic guidance stereotaxis in the management of intracranial mass lesions. Neurosurgery 1983;12:277-85.
- Barnett GH, Kormos DW, Sator K, Weizenberger J. Use of a frameless, armless stereotactic wand for brain tumor localization with two-dimensional and three-dimensional neuroimaging. Neurosurgery 1993:674-678.
- Buchoiz RD, Smith KR, Henderson J. Intraoperative localization using a three dimensional optical digitizer. Proc SPIE 1993;1894:312-322.
- Galloway RL, Marcinuas RJ, Latimer JW. The accuracies of four stereotactic frame systems: an independent assessment. Biomed Instrument Technol 1991;25:457-60.
- Guthrie BL, Adler JR. Computer-assisted preoperative planning, interactive surgery, and frameless stereotaxy. Clin Neurosurg 1995;38:112-31.
- Heilbrun MP, Roberts TS, Apuzzo MLJ, Wells TH, Sabshin JK. Preliminary experience with Brown--Roberts--Wells (BRW) computerized tomography stereotaxic guidance system. J Neurosurg 1983; 59:217-22.
- Marcinuas RJ, Galloway RL, Fitzpatrick JM. A universal system for interactive image-directed neurosurgery. Stereotact Funct Neurosurg 1992;58:108-13.
- Roberts DW, Strohbehn JW, Hatch JF, Murray W, Kettenberger H. A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope. J Neurosurg 1986;65:545-9.
- Watanabe E, Watanabe T, Manaka S. Three-dimensional digitizer (neuronavigator): new equipment of computed tomography-guided stereotactic surgery. Surg Neurol 1987;27:543-7.
- Watanabe E, Mayangi Y, Kosugi Y, Manaka S, Takakura K. Open Surgery assisted by the neuronavigator: a stereotactic, articulated, sensitive arm. Neurosurgery 1991;28:792-800.
- Zinreich JS, Tebo SA, Long DM, et al. Frameless stereotactic integration of CT imaging data: accuracy and initial applications. Radiology 1993;188:735-43.
- Black PM, Moriaty T, Alexander EA, et al. Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications. Neurosurgery 1997;41:831-45.
- Martin C, Alexander EA, Wong T, Schwartz R, Jolesz F, Black PM. Surgical treatment of low-grade gliomas in the intraoperative magnetic resonance imager. Neurosurg Focus 4, Article 8. 1998.
- Seifert V, Zimmermann M, Trantakis C, et al. Open MRI-guided neurosurgery. Acta Neurochir (Wien) 1999;141:455-64.
- Lerch KD. Stereotactically-guided microsurgical resection of deep-seated brain lesions: minimization of established and development of new unconventional approaches. Minim Invasive Neurosurg 1995;38:60-78.
- Lerch KD, Schaefer D, Palleske H. Stereotactic micro-resection of small cerebral vascular malformations (SCVM). Acta Neurochir (Wien) 1994;130:28-34.
- Shellock FG, Shellock VJ. Cranial bone flap fixation clamps: compatibility at MR imaging. Radiology 1998; 207:822-5.
- Silverman SG, Collick BD, Figueira MR, et al. Interactive MR-guided biopsy in an open-configuration MR imaging system. Radiology 1995-175.
- Moriaty TM, Kikins R, Jolesz FA, Black PM, Alexander EA. Magnetic resonance imaging therapy. Neurosurg Clin North Am 1996;7:323-31.
- Steiner P, Schoenberger AW, Penner EA, et al. Interactive stereotaxic interventions in superconducting, open 0.5-Tesla MRI tomography. Fortschr Rontgenstr 1996;165:276-80.
- Schenk JF, Jolesz FA, Roemer PB, et al. Superconducting open configuration MRI system for image-guided therapy. Radiology 1995;195:805-14.
- International Organisation For Standardization. Implants for surgery-metallic materials: Part 3: Wrought titanium 6-aluminium 4-vanadium alloys. ISO 5832-3, 1990.
- New PF, Rosen BR, Brady TJ, et al. Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. Radiology 1983; 147:139-48.
- Shellock FG, Detrick MS, Brant-Zawadski MN. MR compatibility of Guglielmi detachable coils. Radiology 1997;203:568-70.
- Shellock FG, Shellock VJ. Vascular access ports and catheters: ex vivo testing of ferromagnetism, heating, and artifacts associated with MR imaging. Magn Reson Imaging 1996;14:443-7.
- Shellock FG, Kanal E. Yasargil aneurysm clips: evaluation of interactions with a 1.5-T MR system. Radiology 1998;207:587-91.
- Shellock FG, Shellock VJ. Spetzler titanium aneurysm clips: compatibility at MR imaging. Radidogy 1998; 206:838-41.
- Planert J, Modler H, Vosshenrich R. Measurements of magnetism-related forces and torque moments affecting medical instruments, implants, and foreign objects during magnetic resonance imaging at all degrees of freedom. Med Phys 1996;23:851-6.
- Kagetsu NJ, Litt AW. Important considerations in measurement of attractive force on metallic implants in MR imagers. Radiology 1991;179:505-8.
- Lewin JS, Duerk JL, Jain VR, Petersilge CA, Chao CP, Haaga JR. Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. AJR Am J Roentgenol 1996;166:1337-45.
Rivet-like titanium clamp fixation of cranial bone flaps during open magnetic resonance-guided neurosurgery
Reprints and Corporate Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
To request a reprint or corporate permissions for this article, please click on the relevant link below:
Academic Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
Obtain permissions instantly via Rightslink by clicking on the button below:
If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.