122
Views
0
CrossRef citations to date
0
Altmetric
Original Article

In silico modelling of influence from low or intermediate frequency magnetic fields on users of wearable insulin pumps

ORCID Icon, &
Pages 926-933 | Received 20 Nov 2017, Accepted 12 Dec 2017, Published online: 03 Jan 2018

References

  • Calcagnini G, Floris M, Censi F, Cianfanelli P, Scavino G, Bartolini P. 2006. Electromagnetic interference with infusion pumps from GSM mobile phones. Health Phys. 90:357–360.
  • Carranza N, Febles V, Hernández JA, Bardasano JL, Monteagudo JL, Fernández de Aldecoa JC, Ramos V. 2011. Patient safety and electromagnetic protection: a review. Health Phys. 100:530–541.
  • Christe B. 2009. Evaluation of current literature to determine the potential effects of radio frequency identification on technology used in diabetes care. J Diabetes Sci Technol. 3:331–335.
  • De Miguel-Bilbao S, Martín MA, Del Pozo A, Febles V, Hernández JA, de Aldecoa JC, Ramos V. 2013. Analysis of exposure to electromagnetic fields in a healthcare environment: simulation and experimental study. Health Phys. 105(5 Suppl 3):S209–S222.
  • De Santis V, Douglas M, Nadakuduti J, Bankler S, Chen XL, Kuster N. 2015. Human exposure from pulsed magnetic field therapy mats: a numerical case study with three commercial product. Bioelectromagnetics. 36:149–161.
  • Dimbylow PJ. 2005. Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields. Phys Med Biol. 50:1047–1070.
  • European Directive. 2013. Directive 2013/35/EU of the European Parliament and of the Council on the minimum health and safety requirements regarding the exposure of workers to the risks arising from physical agents (electromagnetic fields) and repealing Directive 2004/40/EC. Off J Eur Union L 179, 56:1–19.
  • European Recommendation. 1999. Council of the European Union Recommendation on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz), 1999/519/EC, OJ. L 199/59.
  • Gryz K, Leszko W, Karpowicz J. 2015. Narażenie na pole elektromagnetyczne w otoczeniu aplikatorów urządzeń magnetoterapeutycznych [Exposure to electromagnetic field near applicators of magnetotherapeutic devices]. Probl Hig Epidemiol. 96:578–585. Polish.
  • Hansson Mild K, Alanko T, Decat G, Falsperla R, Gryz K, Hietanen M, Karpowicz J, Rosi P, Sandström M. 2009. Exposure of workers to electromagnetic fields. a review of open questions on exposure assessment techniques. Int J Occup Saf Ergon. 15:3–33.
  • Information service: Medtronic Poland Sp z o.o. Available from: https://www.pompy-medtronic.pl/ [accessed 2017 Dec 16].
  • International Commission on Non-Ionizing Radiation Protection (ICNIRP). 2010. Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz–100 kHz). Health Phys. 99:818–836.
  • ITIS Foundation Virtual Population. Available from: https://www.itis.ethz.ch/virtual-population/virtual-population/vip3/ [accessed 2017 Dec 16].
  • Karpowicz J. 2015. Environmental and Safety Aspects of the Use of EMF in Medical Environment. In: Markov MS, editor. Electromagnetic Fields in Biology and Medicine. Boca Raton (FL): Taylor & Francis Group; p. 343–364.
  • Karpowicz J, Gryz K. 2013. An assessment of hazards caused by electromagnetic interaction on humans present near short-wave physiotherapeutic devices of various types including hazards for users of electronic active implantable medical devices (AIMD). Biomed Res Int. 2013:Article ID 150143. doi: 10.1155/2013/150143
  • Luca C, Andritoi D, Corciova C, Ciorap R. 2015. Study on the influence of wireless communication technology on infusion pumps. Proceedings of the International Conference and Exposition on Electrical and Power Engineering, 20–22 October, Iasi, Romania.
  • Rodgers J. 2008. Using insulin pumps in diabetes. a guide for nurses and other health professionals. Chichester: John Wiley & Sons.
  • Zhang Y, Jones PL, Jetley R. 2010. A hazard analysis for a generic insulin infusion pump. J Diabetes Sci Technol. 4:263–283.
  • Zradziński P. 2015a. The examination of virtual phantoms with respect to their involvement in a compliance assessment against the limitations of electromagnetic hazards provided by European Directive 2013/35/EU. Int J Occup Med Environ Health. 28:781–792.
  • Zradziński P. 2015b. Difficulties in applying numerical simulations to an evaluation of occupational hazards caused by electromagnetic fields. Int J Occup Saf Ergon. 21:213–220.
  • Zradziński P. 2016. A comparison of ICNIRP and IEEE guidelines to evaluate low frequency magnetic field localised exposure. Proceedings of the 17th International Conference Computational Problems of Electrical Engineering (CPEE); Sep 14-17, Sandomierz, Poland, IEEE Conference Publications. p. 1–4.
  • Zradziński P, Karpowicz J, Gryz K, Leszko W. 2017a. An evaluation of the direct electromagnetic influence on the safety of users of wearable insulin pumps caused by low frequency magnetic field – IFMBE Proceedings of Joint Conference of the European Medical and Biological Engineering Conference, EMBEC 2017 and Nordic-Baltic Conference on Biomedical Engineering and Medical Physics, NBC 2107; Jun 11-15, Tampere, Finland, 65:1008–1011.
  • Zradziński P, Karpowicz J, Gryz K, Leszko W. 2017b. Ocena zagrożeń wynikających z oddziaływania pola magnetycznego emitowanego przez aplikator magnetoterapeutyczny dla użytkowników protez słuchu [Evaluation of hazards caused by magnetic field emitted from magnetotherapy applicator to the users of none conduction hearing prostheses]. Med Pr. 68:469–477. Polish.
  • Zradziński P, Karpowicz J, Gryz K, Leszko W. 2018. An evaluation of the safety of users of active implantable medical devices (AIMD) in the working environment in terms of expose to electromagnetic fields – a practical approach to the requirements of European Directive 2013/35/EU. Int J Occup Med Environ Health. [in press].

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.