- Jones MA. Clinical reasoning in manual therapy. Physical Therapy 1992; 72: 875-884.
- Rothstein JM, Campbell SK, Echternach JL et al. Task force on standards for measurement in physical therapy. Standards for test and measurements in physical therapy. Physical Therapy 1991; 71: 589-622.
- Maitland GD. Vertebral Manipulation, fifth edition. London, UK: Butterworth & co Ltd, 1986.
- Keating J, Matyas TA, Bach TM. The effect of training on physical therapists' ability to apply specified forces of palpation. Physical Therapy 1993; 73: 38-46.
- Lee M, Latimer J, Maher C. Manipulation: investigation of a proposed mechanism. Clinical Biomechanics 1993; 8: 302-306.
- Lee M, Moseley A, Refshauge K. Effect of feedback on learning a vertebral joint mobilization skill. Physical Therapy 1990; 70: 97-104.
- Lee M, Svensson NL. Measurement of stiffness during simulated spinal physiotherapy. Clinical Physics Physiological Measurement 1990; 11: 201-207.
- Lee R, Evans J. Load-displacement-time characteristics of the spine under posteroanterior mobilization. Australian Journal of Physiotherapy 1992; 38: 115-123.
- Simmonds MJ, Kumar S, Lechelt E. Use of a spinal model to quantify the forces and motion that occur during therapists' tests of spinal motion. Physical Therapy 1995; 75: 212-222.
- Grieve GP. Mobilization of the Spine. Notes on Examination, Assessment and Clinical Method, fourth edition. New York: Churchill Livingston, 1984.
- Binkley J, Stratford PW, Gill C. Interrater reliability of lumbar accessory motion mobility testing. Physical Therapy 1995; 75: 786-792.
- Gonnella C, Paris SV, Kutner M. Reliability in evaluating passive intervertebral motion. Physical Therapy 1982; 62: 436-444.
- Keating JC, Bergmann TF, Jacobs GE et al. Inter-examiner reliability of eight evaluative dimensions of lumbar segmental abnormality. Journal of Manipulative and Physiological Therapeutics 1990; 13: 463-470.
- Maher C, Adams R. Reliability of pain and stiffness assessments in clinical manual lumbar spine examination. Physical Therapy 1994; 74: 801-811.
- Boline PD, Haas M, Meyer JJ et al. Inter-examiner reliability of eight evaluative dimensions of lumbar segmental abnormality: part II. Journal of Manipulative and Physiological Therapeutics 1993; 16: 363-374.
- Jull G, Bogduk N, Marsland A. The accuracy of manual diagnosis for cervical zygapophysial joint pain syndromes. The Medical Journal of Australia 1988; 148: 233-236.
- Jull G, Treleaven J, Versace G. Manual examination: is pain provocation a major cue for spinal dysfunction? Australian Journal of Physiotherapy 1994; 40: 159-165.
- Newton M, Waddell G. Reliability and validity of clinical measurement of the lumbar spine in patients with chronic low back pain. Physiotherapy 1991; 77: 796-800.
- Simmonds MJ, Kumar S. Health care ergonomics, part II: location of body structures by palpation--a reliability study. International Journal of Industrial Ergonomics 1993; 11: 145-151.
- Latimer J, Goodsell MM, Lee M et al. Evaluation of a new device for measuring responses to posteroanterior forces in a patient population, part 1: reliability testing. Physical Therapy 1996; 76: 158-165.
- Lee M, Esler MA, Mildren J. Effect of extensor muscle activation on the response to lumbar posteroanterior forces. Clinical Biomechanics 1993; 8: 115-119.
- Lee M, Lau H, Lau T. Sagittal plane rotation of the pelvis during lumbar posteroanterior loading. Journal of Manipulative and Physiological Therapeutics 1994; 17: 149-155.
- Shirley D, Lee M. A preliminary investigation of the relationship between lumbar posteroanterior mobility and low back pain. The Journal of Manual & Manipulative Therapy 1993; 1: 22-25.
- Kaltenborn FM. Mobilization of the Extremity Joints. Examination and Basic Treatment Techniques, third edition. Oslo, Norway: Olaf Norlis Bokhandel, 1985.
- Threlkeld AJ. The effect of manual therapy on connective tissue. Physical Therapy 1992; 72: 893-902.
- Kumar S, Panjabi MM. In vivo axial rotations and neutral zones of the thoracolumbar spine. Journal of Spinal Disorders 1995; 8: 253-263.
- Mior SA, McGregor M, Schut B. The role of experience in clinical accuracy. Journal of Manipulative and Physiological Therapeutics 1990; 13: 68-71.
Posteroanterior motion test of a lumbar vertebra: accuracy of perception
Reprints and Corporate Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
To request a reprint or corporate permissions for this article, please click on the relevant link below:
Academic Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
Obtain permissions instantly via Rightslink by clicking on the button below:
If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.