References
- American College of Surgeons. Advanced Trauma Life Support Student Manual. Chicago, IL: ACS, 1989, p 13.
- Campbell JE, for the Alabama Chapter ACEP. Basic Trauma Life Support: Advanced Prehospital Care, 2nd edition, Englewood Cliffs, NJ: Prentice-Hall, 1988, p 128.
- Worsing RA. Principles of prehospital care of musculoskeletal injuries. Emerg Med Clin North Am. 1984;2:205–17.
- Carolise NL. Emergency Care in the Streets. Boston, MA: Little, Brown & Co., 1987, p 370.
- Lind B, Bake B, Lundqvist C, Nordwall A. Influence of halo vest treatment on vital capacity. Spine. 1987;12:449–52.
- Schafermeyer RW, Ribbeck BM, Gaskins J, Thompson S, Harlan M, Attkisson A. Respiratory effects of spinal immobilization in children. Ann Emerg Med. 1991;20:1017–9.
- Bauer D, Kowalski R. Effect of spinal immobilization devices on pulmonary function in the healthy non-smoking man. Ann Emerg Med. 1988;17:915–8.
- Walsh M, Grant T, Mickey S. Lung function compromised by spinal immobilization [letter]. Ann Emerg Med. 1990;19:615–6.
- Schriger DL, Larmon B, LeGassick T, Blinman T. Spine immobi-lization on a flat backboard: does it result in neutral position of the cervical spine? Ann Emerg Med. 1991;20:878-81.
- Treloar DJ, Nypaver M. Angulation of the pediatric cervical spine with and without cervical collar. Pediatr Emerg Care. 1997;13:5–8.
- Herzenberg JE, Hensinger RN, Dedrick DK, Phillips WA. Emer-gency transport and positioning of young children who have an injury of the cervical spine. (The standard backboard may be hazardous.) J Bone Joint Surg. 1989;71A:15–22.
- Wolk BH. Swedes stress mobility and speed in industrial emer-gency rescue. Occup Health Safety N Digest. 1987;3(6)17–8.
- Edsall L. Filling a vacuum in safety gear: Swedish cocoon pro-tects from additional injury. Autoweek. 1989; Jan 30:51.
- Reislinger F, Bachraty M, Nadvornik P, Kolarik J. A multipurpose vacuum mattress in health services. Rozhl Chir. 1990;69:619–21.
- Renberg B. International perspectives, a look at EMS in other parts of the world: Sweden. Rescue-EMS News. 1990;Mar-Apr:19–21.
- Schetrumph JR. Instant splints: vacuum compacted polystyrene balls. Br J Plast Surg. 1973;26:393–7.
- Dickens CW. Personalized fixation using a vacuum consolida-tion technique. Br J Radiol. 1981;54:257–8.
- Letts RM, Hobson DA. The vacuum splint: an aid in emergency splinting of fractures. CMAJ. 1973;109:599–600.
- Rosen PB, McSwain NE, Arata M, Shahl S, Mercer D. Compari-son of two new immobilization collars. Ann Emerg Med 1992;21: 1189–95.
- Nadvornik P, Kolarik J, Svoboda V. Position of whole body stereotactic device among targeted interventions into human or-ganism. Zentralbl Neurochir. 1990;51(1):18–20.
- Povey RW. A vacuum splint for use in orthopedic operations. J Bone Joint Surg. 1970;52B:535–9.
- Zamel N, Altose MD, Speir WA. Statement on spirometry, a re-port of the section on respiratory pathophysiology. Chest. 1983; 83:547–50.
- Lebowitz MD, Knudson RJ, Robertson G, Burrows B. Significance of intra-individual changes in maximum expiratory flow volume and peak expiratory flow measurements. Chest. 1982;81:566–70.
- Barney BN, Cordell WH, Miller E. Pain associated with immobi-lization on rigid spine boards [abstract]. Ann Emerg Med. 1989; 18:918.
- Cordell WH, Hollingsworth JC, Olinger ML, et al. Pain and tis-sue-interface pressure during spine board immobilizations. Ann Emerg Med. 1995;26:31–6.
- Chan D, Goldberg R, Tascone A, Harmon S, Chan L. The effect of spinal immobilization on healthy volunteers. Ann Emerg Med. 1994;23:48–51.