235
Views
10
CrossRef citations to date
0
Altmetric
Review Article

Principles and initial experience of a new device for dissection and hemostasis

, &
Pages 58-65 | Published online: 10 Jul 2009

References

  • Metzelder M. L., Kubler J., Petersen C., Gluer S., et al. Laparoscopic nephroureterectomy in children: a prospective study on Ligasure versus Clip/Ligation. Eur J Pediatr Surg 2006; 16: 241–4
  • Lyons T. L., Winer W. K. An innovative bipolar instrument for laparoscopic surgery. JSLS 2005; 9: 39–41
  • Wu M. P., Ou C. S., Chen S. L., Yen Y. E. T., et al. Complications and recommended practices for electrosurgery in laparoscopy. Am J of Surg 2000; 179: 67–73
  • Ong A. M., Su L. M., Varkarakis I., Inagaki T., et al. Nerve sparing radical prostatectomy: effects of hemostatic energy sources on the recovery of cavernous nerve function in a canine model. J Urol 2004; 172: 1318–22
  • Smith T. L., Smith J. M. Electrosurgery in Otolaryngology‐Head and Neck surgery:Principles, Advantages and Complications. Laryngoscope 2001; 111: 769–80
  • Isaacson K. B. New developments in radiofrequency technology for laparoscopic surgery. Contemporary Obst Gyn 2002; 4: 26–42
  • Malis L. I. Electrosurgery and bipolar technology. Operative neurosurgery 2005; 58: 1–11
  • Wright V. C. Contemporaray electrosurgery: physics for physicians. J Am Board Fam Pract 1994; 39: 119–22
  • Phipps J. H. Understanding electrosurgery: safety and efficiency. Introduction to gynecological endoscopy, A Lower, C Sutton, G Grudzinskas. Isis Medical Media, Oxford UK 1996; 39–56
  • Harold K. L., Pollinger H., Matthews B. D., Kercher K. W., et al. Comparison of ultrasonic energy, bipolat termal energy, and vascular clips for hemostasis of small‐, medium‐, and large‐sized arteries. Surg Endosc 2003; 17: 1228–30
  • Targarona E. M., Balaque C., Marin J., Neto R. B., Martinez C., et al. Energy Sources for Laparoscopic Colectomy: A Prospective Randomized Comparison of Conventional Electrosurgery, Bipolar Computer‐Controlled Electrosurgery and Ultrasonic Dissection. Operative Outcome and Costs Analysis. Surgical Innovation 2005; 12: 339–44
  • Heniford B. T., Matthews B. D., Sing R. F., Backus C. Initial results with an electrothermal bipolar vessel sealer. Surg Endosc 2001; 5: 799–801
  • Erian J., El‐Toukhy T., Chandakas S., Theodoridis T., et al. One hundred cases of laparoscopic subtotal hysterectomy using the PK and Lap Loop systems. J Minim Invasive Gynecol 2005; 12: 365–9
  • Pietrow P. K., Weizer A. Z., L'Esperance J. O., Auge B. K., et al. PlasmaKinetic bipolar vessel sealing: burst pressures and thermal spread in an animal model. J Endourol 2005; 19: 107–10
  • Landman J., Kerbl K., Rehman J., Andreoni C., et al. Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model. J Urol 2003; 169: 697–700
  • Marcello P. W., Roberts P. L., Rusin L. C., Holubkov R., et al. Vascular pedicle ligation during laparoscopic colectomy. A prospective randomized trial. Surg Endosc 2006; 20: 263–9
  • Novitsky Y. W., Rosen M. J., Harrell A. G., Sing R. F., et al. Evaluation of the efficacy of the electrosurgical bipolar vessel sealer (LigaSure) devices in sealing lymphatic vessels. Surg Innov 2005; 12: 155–60
  • Santa‐Cruz R. W., Auge B. K., Lallas C. D., Preminger G. M., et al. Use of bipolar laparoscopic forceps to occlude and transect the retroperitoneal vasculature: a porcine model. J Endourol 2003; 17: 181–5
  • Carbonell A. M., Joels C. S., Kercher K. W., Matthews B. D., et al. A comparison of laparoscopic bipolar vessel sealing devices in the hemostasis of small‐, medium‐, and large‐sized arteries. J Laparoendosc Adv Surg Tech A 2003; 13: 377–80
  • Wittgrove A. C., Clark G. W. Laparoscopic gastric by pass, roux‐en‐Y:experience of 27 cases with 3–18 months follow‐up. Obes Surg 1996; 6: 54
  • Wang C. J., Yuen L. T., Yen C. F., Lee C. L., et al. Comparison of the efficacy of the pulsed bipolar system and conventional bipolar electrosurgery in laparoscopically assisted vaginal hysterectomy. J Laparoendosc Adv Surg Tech A 2005; 15: 361–4
  • Ou C. S., Joki J., Wells K., Zabriske V., et al. Total laparoscopic hysterectomy using multifunction grasping, coagulating, and cutting forceps. J Laparoendosc Adv Surg Tech A 2004; 14: 67–71
  • Rassweiler J., Tsivian A., Kumar A. V., Lymberakis C., et al. Oncological safety of laparoscopic surgery for urological malignancy: experience with more than 1,000 operations. J Urol 2003; 169: 2072–5
  • Guillonneau B., Cappele O., Martinez J. B., Navarra S., et al. Robotic assisted, laparoscopic pelvic lymph node dissection in humans. J Urol 2001; 165: 1078–81
  • Solberg A., Angelsen A., Bergan U., Haugen O. A., et al. Frequency of lymphoceles after open and laparoscopic pelvic lymph node dissection in patients with prostate cancer. Scand J Urol Nephrol 2003; 37: 218–21
  • Rassweiler J., Marrero R., Hammady A., Erdogru T., et al. Transperitoneal laparoscopic radical prostatectomy: ascending technique. J Endourol 2004; 18: 593–9
  • Harrel A. G., Kercher K. W., Heniford B. T. Energy sources in laparoscopy. Semin Laparosc Surg 2004; 11: 201–9
  • Sengupta S., Webb D. R. Use of a computer‐controlled bipolar dia thermy system in radical prostatectomies and other open urological surgery. ANZ J Surg 2001; 71: 538–40
  • Harrison J. D., Morris D. L. Artery weld strength after bipolar electrocoagulation is affected by electrolyte solutions around the artery. Gastrointest Endosc 1993; 39: 546–8
  • Liboon J., Funkhouser W., Terris D. J. A comparison of mucosal incisions made by scalpel, CO2 laser electrocautery and constant‐voltage electrocautery. Otolaryngol Head Neck Surg 1997; 116: 379–85
  • Sibbons D. R., Southgate A. Comparison of wound‐healing and tissue effects using the Gyrus PlasmaKnife with monopolar, Coblation, and Harmonic Scalpel methodologies. Comp Clin pathol 2006; 15: 17–26
  • Leinbach R. F., Markwell S. J., Colliver J. A., Lin S. Y. Hot versus cold tonsillectomy. A systematic review of the literature. Otolaryngol Head Neck Surg 2003; 129: 360–4
  • Carlander J., Johansson K., Lindstrom S., Velin A. K., et al. Comparison of experimental nerve injury caused by ultrasonically activated scalpel and electrosurgery. Br J Surg 2005; 92: 772–7
  • Owaki T., Nakano S., Arimura K., Aikou T. The ultrasonic coagulating and cutting system injures nerve function. Endoscopy 2002; 34: 575–9
  • Donzelli J., Leonetti J. P., Wurster R. D., Lee J. M., et al. Neuroprotection due to irrigation during bipolar cautery. Arch Otolaryngol Head Neck Surg 2000; 126: 149–53
  • Gill I. S., Osamu U., Mauricio R., et al. Lateral pedicle control during laparoscopic radical prostatectomy:Refined technique. Urology 2005; 65: 23–7
  • Ahlering T., Skarecky B. S., Borin J. Impact of cautery‐free preservation of neurovascular bundles on early return of potency. J Endourology 2006; 20: 586–9
  • Selli C., De Antoni P., Moro U., Macchiarella A., et al. Role of bladder neck preservation in urinary continence following radical retropubic prostatectomy. Scand J Urol Nephrol 2004; 38: 32–7
  • Weldon V. E., Tavel F. R., Neuwirth H. Continence, potency and morbidity after radical perineal prostatectomy. J Urol 1997; 158: 1470–5
  • Mayooran Z., Pearce S., Tsaltas J., Rombauts L., et al. Ignorance of electrosurgery BJOG: an international journal of obstetrics and gynaecology. 2004; 111: 1413–8
  • Levy B., Emery L. Randomised trial of suture versus electrosurgical bipolar vessel sealing in vaginal hysterectomy. Obst Gynecol 2003; 102: 147–51

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.