References
- Koh T HHG, Eyre J A, Aynsley-Green A. Neonatal hypoglycaemia—the controversy regarding definition. Arch Dis Child 1988; 63: 1386–8
- Cornblath M, Schwartz R, Aynsley-Green A, Lloyd J K. Hypoglycaemia in infancy: The need for a rational definition. Pediatrics 1990; 85: 834–7
- Harrad R A, Cockram C S, Plomb A P, Stone S, Fenwick P, Sonksen P H. The effect of hypoglycemia on visual function: A clinical and electrophysiological study. Clin Sci 1985; 69: 673–9
- Cornblath M, Schwartz R. Disorders of Hypoglycemia in Infancy, 3rd ed. Blackwell, Boston 1991
- Schwartz R. Neonatal hypoglycaemia—back to basics in diagnosis and treatment. Diabetes 1991; 40(suppl 2)71–3
- Koh T HHG, Aynsley-Green A, Tarbit M, Eyre J A. Neural dysfunction during hypoglycaemia. Arch Dis Child 1988; 63: 1353–8
- Lucas A, Morley R, Cok T J. Adverse neurodevelopmental outcome of moderate neonatal hypoglycaemia. Br Med J 1988; 297: 1304–8
- Pryds O, Christensen N J, Friis-Hansen B. Increased cerebral blood flow and plasma epinephrine in hypoglycemic preterm neonates. Pediatrics 1990; 85: 172–6
- Kunst A, Draeger B, Ziegenhorn J. Glucose—UV methods with hexokinase and glucose-6-phosphate dehydrogenase. Methods of Enzymatic Analysis, 3rd ed, H U Bergmeyer. Verlag Chemie, Weinheim 1984; Vol 6
- Schlebusch H, Sorger M, Voll A, Paffenholz I. Netzunabhängige Kleingeräte zur Blutzuckerbestimmung im Krankenhaus—Präzision, Richtigkeit, Hämatokrit — und Temperatureinfluß. Lab Med 1991; 15: 535–40
- Schlebusch H, Niesen M, Paffenholz I. 1st eine zuverlässige Blutglucosebestimmung beim Neugeborenen mit dem Kleinrellektometer Reflolux S möglich?. Klin Paediatr 1993; 205: 111–5
- Bablok W, Passing H, Bender R, Schneider B. A general regression procedure for method transformation. J Clin Chem Clin Biochem 1988; 26: 783–90
- National Committee for Clinical Laboratory Standards. User comparison of quantitative clinical laboratory methods using patients samples; proposed guideline. NCCLS publication EP9-P, Villanova, PA 1986
- Schlebusch H. Point-of-care testing. Eur J Clin Chem Clin Biochem 1994; 33: A160–1
- Zaloga G P. Evaluation of bedside testing options for the critical care unit. Chest 1990; 97(suppl)185–90
- Fleisher M, Schwartz M K. Strategies of organization and service for the critical-care laboratory. Clin Chem 1990; 36: 1557–61
- Chan A YW, Ho C S, Cockram C S, Swaminathan R. Handling of blood specimens for glucose analysis. J Clin Chem Clin Biochem 1990; 28: 185–6
- Burrin J M, Alberti K GMM. What is glucose: Can it be measured?. Diabet Med 1990; 7: 199–206
- Passey R B, Gillum R L, Fuller J B. Evaluation and comparison of 10 glucose methods and the reference method recommended in Proposed Product Class Standard. Clin Chem 1977; 23: 131–9
- Schlebusch H, Sorger M, Paffenholz I, Harnack H, Geilenkeuser W J. Glucometer Elite—ein neues Gerät für die Blutzucker-Selbstkontrolle des Diabetikers. Lab Med 1994; 18: 455–60
- Mattless D R, Brown E, Watson A. Pen-sized digital 30-second blood glucose meter. Lancet 1987; 1: 778–9
- Conrad P D, Sparks J W, Osberg I, Abrams L, Hay W W, Jr. Clinical application of a new glucose analyzer in the neonatal intensive care unit: Comparison with other methods. J Pediatr 1989; 114: 281–4
- Holtrop P C, Madison K A, Kienchle F F, Karcher R E, Botten D G. A comparison of chromogen test strip and serum glucose values in newborns. Am J Dis Child 1990; 144: 183–5
- Keener P A, Tideman A, Maijala D, Lemons J A. Reliability of the Glucosemeter reflectance photometer in assessing hypoglycemia in the neonate. J Perinatol 1986; 6: 51–6
- Lin H C, Maguire C, Oh W. Accuracy and reliability of glucose reflectance meters in high-risk neonate. J Pediatr 1989; 115: 998–1000
- Trinick T R, Duly E. Experience of a quality assessment scheme for non-laboratory glucose meters. J Clin Pathol 1992; 45: 77–8