25
Views
0
CrossRef citations to date
0
Altmetric
Original

Future directions in neonatal hearing screening

Pages 94-98 | Published online: 11 Jul 2009

References

  • Kemp DT. Stimulated acoustic emissions from within the human auditory system. J Acoust Soc Am. 1978; 64: 1386–91
  • Ciorba, A, Hatzopoulos, S, Camurri, L, Negossi, L, Rossi, M, Cosso, D, Martini, A. Neonatal newborn hearing screening: four years of experience at the Ferrara University Hospital (Cheap Project). Acta Otorhinolaryngol Ital. (in press).
  • White KR, Vohr BR, Meyer S, Widen JE, Johnson JL, Gravel JS, et al. A multisite study to examine the efficacy of the otoacoustic emission/automated auditory brainstem response newborn hearing screening protocol: research design and results of the study. Am J Audiol. 2005; 14: S186–99
  • Cone-Wesson B, Dowell R, Tomlin D, Rance G, Ming Wu. The Auditory Steady State Response. Comparisons with the auditory brainstem response. J Am Acad Audiol. 2002; 13: 173–87
  • Dimitrijevic A, John MS, Van Roon P, Purcell DW, Adamonis J, Ostroff J, Nedzelski JM, Picton TW, et al. Estimating the audiogram using multiple auditory steady state responses. J Am Acad Audiol. 2002; 13: 205–24
  • John MS, Picton TW. Human auditory steady-state responses to amplitude-modulated tones: phase and latency measurements. Hear Res. 2000; 141: 57–79
  • Gorga MP, Neely ST, Hoover BM, Dierking DM, Beauchaine KL, Manning C. Determining the upper limits of stimulation for auditory steady-state response measurements. Ear Hear 2004; 25: 302–7
  • Stueve MP, O'Rourke C. Estimation of hearing loss in children: comparison of auditory steady-state response, auditory brainstem response, and behavioural test methods. Am J Audiol. 2003; 12: 125–36
  • Luts H, Desloovere C, Kumar A, Vandermeersch E, Wouters J. Objective assessment of frequency-specific hearing thresholds in babies. Int J Pediatr Otorhinolaryngol. 2004; 68: 915–26
  • Swanepoel D, Hugo R, Roode R. Auditory steady-state responses for children with severe to profound hearing loss. Arch Otolaryngol Head Neck Surg. 2004; 130: 531–5
  • Whitehead ML, McCoy MJ, Lonsbury-Martin BL, Martin GK. Dependence of distortion-product otoacoustic emissions in primary tone level in normal and impaired ears. I. Effects of decreasing L2 below L1. J Acoust Soc Am. 1995a; 97: 2346–58
  • Whitehead ML, Stagner BB, Lonsbury-Martin BL, Martin GK. Effects of ear-canal standing waves on measurements of distortion-product otoacoustic emissions. J Acoust Soc Am. 1995b; 98: 3202–14
  • Shera CA, Guinan JJ, Jr. Evoked otoacoustic emissions arise by two fundamentally different mechanisms: a taxonomy for mammalian OAEs. J Acoust Soc Am. 1999; 105: 782–98
  • Janssen T, Kummer P, Arnold W. Growth behavior of the 2f1-f2 distortion product otoacoustic emission in tinnitus. J Acoust Soc Am. 1998; 103: 3418–30
  • Dorn PA, Konrad-Martin D, Neely ST, Keefe DH, Cyr E, Gorga MP. Distortion product otoacoustic emission input/output functions in normal-hearing and hearing-impaired human ears. J Acoust Soc Am. 2001; 110: 3119–31
  • Gorga MP, Neely ST, Dierking DM, Dorn PA, Hoover BM, Fitzpatrick DF. Distortion product otoacoustic emission suppression tuning curves in normal-hearing and hearing-impaired human ears. J Acoust Soc Am. 2003; 114: 263–78
  • Mills DM, Rubel ED. Developement of the cochlear amplifier. J Acoust Soc Am. 1996; 100: 428–41
  • Kummer P, Janssen T, Arnold W. The level and growth behaviour of the 2f1-f2 distortion product otoacoustic emission and its relationship to auditory sensitivity in normal hearing and cochlear hearing loss. J Acoust Soc Am. 1998; 103: 3431–44
  • Boege P, Janssen T. Pure-tone threshold estimation from extrapolated distortion product otoacoustic emission I/O-functions in normal and cochlear hearing loss ears. J Acoust Soc Am. 2002; 111: 1810–8
  • Neely ST, Gorga MP, Dorn PA. Cochlear compression estimates from measurements of distortion-product otoacoustic emissions. J Acoust Soc Am. 2003; 114: 1499–1507
  • Gorga MP, Neely ST, Dorn PA, Hoover BM. Further efforts to predict pure-tone thresholds from distortion product otoacoustic emission input/output functions. J Acoust Soc Am. 2003; 113: 3275–84
  • Janssen T, Klein A, Gehr D. Automatische Hörschwellenbestimung bei Neugeborenen mit extrapolierten DPOAE-Wachstumsfunktionen. Eine neue Hörscreening-Methode. HNO 2003; 16: 125–8
  • Oswald JA, Janssen T. Weighted DPOAE I/O-functions: a tool for automatically assessing hearing loss in clinical application. Z Med Physik. 2003; 13: 93–8

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.