Rapid pre-tension loss in the Ilizarov external fixator: An in vitro study

, &
Pages 654-660 | Received 05 Jan 2007, Accepted 20 Feb 2007, Published online: 08 Jul 2009

  • Arazi M, Memik R, Ögün T C, Yel M. Ilizarov external fixation for severly comminuted supracondylar and intercondylar fractures in the distal femur. J Bone Joint Surg (Br) 2001; 83(5)663–7
  • Aronson J, Harp J H. Mechanical considerations in using tensioned wires in a transosseous external fixator system. Clin Orthop 1992, 280: 23–9
  • Augat P, Burger J, Schorlemmer S, Henke T, Peraus M, Claes L. Shear movement at the fracture site delays healing in a diaphysial fracture model. J Orthop Res 2003; 21: 1011–7
  • Bishop N E, van Rhijn M, Tami I, Corveleijn R, Schneider E, Ito K. Shear does not necessarily inhibit bone healing. Clin Orthop 2006, 443: 307–14
  • Bronson D G, Samchukov M L, Birch J G, Browne R H, Ashman R B. Stability of external circular fixation: a multi-variable biomechanical analysis. Clin Biomech 1998; 13: 441–8
  • Catagni M A, Malzev V, Kirienko A. Advances in Ilizarov Apparatus Assembly. 2nd revised. Medicalplastic srl, MilanItaly 1996
  • Delprete C, Gola M M. Mechanical performance of external fixators with wires for the treatment of bone fractures–Part II: wire tension and slippage. J Biomech Eng 1993; 115: 37–42
  • Duda G N, Kassi J-P, Hoffmann J E, Riedt R, Khodadayan C, Raschke M. Mechanisches verhalten von Ilizarovringfixateuren: Einfluss der gestaltparameter auf die steifigkeit und konsequenzen für den klinischen einsatz. Unfallchirurg 2000; 103: 839–45
  • Duda G N, Sollmann M, Sporrer S, Hoffmann J E, Kassi J-P, Khodadayan C, Raschke M. Interfragmentary motion in tibial osteotomies stabilized with ring fixators. Clin Orthop 2002, 396: 163–72
  • Hillard P J, Harrison A J, Atkins R M. The Yielding of tensioned fine wires in the Ilizarov frame. Proc Inst Mech Eng [H] 1998; 212(1)37–47
  • Ilizarov G A. Clinical application of the tension-stress effect for limb lengthening. Clin Orthop 1990, 250: 8–26
  • Marsh D R, Shah S, Elliott J, Kurdy N. The Ilizarov method in nonunion, malunion and infection of fractures. J Bone Joint Surg (Br) 1997; 79(2)273–9
  • Mullins M M, Davidson A W, Goodier D, Barry M. The biomechanics of wire fixation in the Ilizarov system. Injury 2003; 34: 155–7
  • Nikonovas A, Harrison A JL. A simple way to model wires used in ring fixators: analysis of the wire stiffness effect on overall fixator stiffness. Proc Inst Mech Eng [H] 2005; 219: 31–42
  • Noordeen M HH, Lavy C BD, Shergill N S, Tuite J D, Jackson A M. Cyclical micromovement and fracture healing. J Bone Joint Surg (Br) 1995; 77(4)645–8
  • Osei N A, Bradley B M, Culpan P, Mitchell J B, Barry M, Tanner K E. Relationship between locking-bolt torque and load pre-tension in the Ilizarov frame. Injury 2006; 37: 941–5
  • Ramesh L J, Rajkumar S A, Rajendra R, Rajagopal H P, Phaneesha M S, Gaurav S. Ilizarov ring fixation and fibular strut grafting for C3 distal femur fractures. J Orthop Surg (Hong Kong) 2004; 12(1)91–5
  • Renard A JS, Schutte B G, Verdonschot N, van Kampen A. The Ilizarov external fixator: What remains of the wire pretension after dynamic loading?. Clin Biomech 2005; 20: 1126–30
  • Sardis A, Panagiotopoulos E, Tyllianakis M, Matzaroglou C, Vandoros N, Lambiris E. The use of the Ilizarov method as a salvage procedure in infected nonunion of the distal femur with bone loss. Journal Bone Joint Surg (Br) 2006; 88(2)232–7
  • Schell H, Epari D R, Kassi J P, Bragulla H, Bail H J, Duda G N. The course of bone healing is influenced by the initial shear fixation stability. J Orthop Res 2005; 23: 1022–8
  • Watson M A, Mathias K J, Maffuli N, Hulkins D WL. The effect of clamping a tensioned wire: implications for the Ilizarov external fixation system. Proc Inst Mech Eng [H] 2003a; 217: 91–8
  • Watson M A, Mathias K J, Maffuli N, Hulkins D WL. Yielding of the clamped-wire system in the Ilizarov external fixator. Proc Inst Mech Eng [H] 2003b; 217: 367–74
  • Watson M A, Mathias K J, Ashcroft G P, Maffuli N, Hulkins D WL, Shepherd D ET. Wire tension in the Ilizarov system: accuracy of the wire-tensioning device. Proc Inst Mech Eng [H] 2005; 219: 355–9
  • Wolf S, Janousek A, Pfeil J, Veith W, Haas F, Duda G, Claes L. The effects of external mechanical stimulation on the healing of diaphyseal osteotomies fixed by flexible external fixation. Clin Biomech 1998; 13: 359–64
  • Yamaji T, Ando K, Wolf S, Augat P, Claes L. The effect of micromovement on callus formation. J Orthop Sci 2001; 6: 571–5

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.