2,610
Views
34
CrossRef citations to date
0
Altmetric
Original papers

Immediate weight bearing after uncemented total hip arthroplasty with an anteverted stem: A prospective randomized comparison using radiostereometry

, , , &
Pages 730-738 | Received 03 Oct 2006, Accepted 05 Apr 2007, Published online: 08 Jul 2009

  • Aldinger P R, Thomsen M, Mau H, Ewerbeck V, Breusch S J. Cementless Spotorno tapered titanium stems: excellent 10–15–year survival in 141 young patients. Acta Orthop Scand 2003; 74(3)253–8
  • Andersson L, Wesslau A, Boden H, Dalen N. Immediate or late weight bearing after uncemented total hip arthroplasty: a study of functional recovery. J Arthroplasty 2001; 16(8)1063–5
  • Blacha J. High osteolysis and revision rate with the hydroxy-apatite-coated ABG hip prostheses: 65 hips in 56 young patients followed for 5–9 years. Acta Orthop Scand 2004; 75(3)276–82
  • Boden H, Adolphson P. No adverse effects of early weight bearing after uncemented total hip arthroplasty: a randomized study of 20 patients. Acta Orthop Scand 2004; 75(1)21–9
  • Chan Y K, Chiu K Y, Yip D K, Ng T P, Tang W M. Full weight bearing after non-cemented total hip replacement is compatible with satisfactory results. Int Orthop 2003; 27(2)94–7
  • Digas G, Thanner J, Anderberg C, Kärrholm J. Bioactive cement or ceramic/porous coating vs. conventional cement to obtain early stability of the acetabular cup. Randomised study of 96 hips followed with Radiostereometry. J Orthop Res 2004; 22(5)1035–43
  • Grant P, Aamodt A, Falch J A, Nordsletten L. Differences in stability and bone remodeling between a customized uncemented hydroxyapatite coated and a standard cemented femoral stem A randomized study with use of radiostereometry and bone densitometry. J Orthop Res 2005; 23(6)1280–5
  • Harris W H, Mulroy R D, Jr, Maloney W J, Burke D W, Chandler H P, Zalenski E B. Intraoperative measurement of rotational stability of femoral components of total hip arthroplasty. Clin Orthop. 1991, 266: 119–26
  • Jacobsen S, Jensen FK, Poulsen K, Sturup J, Retpen J B. Good performance of a titanium femoral component in cementless hip arthroplasty in younger patients: 97 arthroplasties followed for 5–11 years. Acta Orthop Scand 2003; 74(4)375–9
  • Jasty M, Bragdon C R, Zalenski E, O'Connor D, Page A, Harris W H. Enhanced stability of uncemented canine femoral components by bone ingrowth into the porous coatings. J Arthroplasty 1997; 12(1)106–13
  • Kärrholm J. Roentgen stereophotogrammetry. Review of orthopedic applications. Acta Orthop Scand 1989; 60(4)491–503
  • Kärrholm J, Malchau H, Snorrason F, Herberts P. Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. J Bone Joint Surg (Am) 1994; 76(11)1692–705
  • Kärrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J. Radiostereometry of hip prostheses. Review of methodology and clinical results. Clin Orthop 1997, 344: 94–110
  • Kim Y H, Kim J S, Cho S H. Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series. J Arthroplasty 1999; 14(5)538–48
  • Kishida Y, Sugano N, Sakai T, Nishii T, Haraguchi K, Ohzono K, et al. Full weight-bearing after cementless total hip arthroplasty. Int Orthop 2001; 25(1)25–8
  • Leali A, Fetto J, Moroz A. Prevention of thromboembolic disease after non-cemented hip arthroplasty. A multimodal approach. Acta Orthop Belg 2002; 68(2)128–34
  • önsten I, Carlsson A S, Sanzen L, Besjakov J. Migration and wear of a hydroxyapatite-coated hip prosthesis. A controlled roentgen stereophotogrammetric study. J Bone Joint Surg (Br) 1996; 78(1)85–91
  • Overgaard S, Lind M, Rahbek O, Bunger C, Søballe K. Improved fixation of porous-coated versus grit-blasted surface texture of hydroxyapatite-coated implants in dogs. Acta Orthop Scand 1997; 68(4)337–43
  • Pilliar R M, Lee J M, Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-sur-faced implants. Clin Orthop 1986, 208: 108–13
  • Rao R R, Sharkey P F, Hozack W J, Eng K, Rothman R H. Immediate weightbearing after uncemented total hip arthroplasty. Clin Orthop 1998, 349: 156–62
  • Ritter M A, Albohm M J, Keating E M, Faris P M, Meding J B. Comparative outcomes of total joint arthroplasty. J Arthroplasty 1995; 10(6)737–41
  • Rogers A, Kulkarni R, Downes E M. The ABG hydroxyapa-tite-coated hip prosthesis: one hundred consecutive operations with average 6-year follow-up. J Arthroplasty 2003; 18(5)619–25
  • Selvik G. Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Acta Orthop Scand. 1989, Suppl 232: 1–51
  • Thanner J, Kärrholm J, Herberts P, Malchau H. Hydroxyapatite and tricalcium phosphate- coated cups with and without screw fixation: a randomized study of 64 hips. J Arthroplasty 2000; 15(4)405–12
  • Tonino A J, Rahmy A I. The hydroxyapatite-ABG hip system: 5– to 7–year results from an international multicentre study. The International ABG Study Group. J Arthroplasty 2000; 15(3)274–82
  • Tveit M, Kärrholm J. Low effectiveness of prescribed partial weight bearing. Continuous recording of vertical loads using a new pressure-sensitive insole. J Rehabil Med 2001; 33(1)42–6
  • Valstar E R, Gill R, Ryd L, Flivik G, Börlin N, Kärrholm J. Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop 2005; 76(4)563–72

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.