- Amstutz H C, Yao J, Markolf K, Dorey F. Stem fracture incidence in Trapezoidal-28 stainless steel hip arthroplasty. Clin Orthop 1990, 256: 105–14
- Aspenberg P, Kolmert L, Person L, Onnerfalt R. Fracture of hip prosthesis due to inadequate welding. Acta Orthop Scand 1987; 58: 479–82
- ASTM E1 12–96 (2004). Standard test methods for determining average grain size. 2004
- Botti T, Gent J, Martell J, Manning D. Trunion fracture of a fully porous-coated femoral stem. J Arthroplasty 2005; 20(7)943–5
- Brown S, Flemming C, Kawalec J. Fretting corrosion accelerates crevice corrosion of modular hip tapers. J Appl Biomater 1995; 6: 19–26
- Charnley J. Fracture of femoral prostheses in total hip replacement. A clinical study. Clin Orthop 1975, 111: 105–20
- Collis D K. Femoral stem failure in total hip replacement. J Bone Joint Surg (Am) 1977; 8: 1033–41
- Dall D M, Learmonth I D, Solomon M I, Miles A W, Davenport J M. Fracture and loosening of Charnley femoral stems. J Bone Joint Surg (Br) 1993; 75: 259–65
- Della Valle A, Becksac B, Anderson J. Late fatigue fracture of a modern cemented forged cobalt chrome stem for total hip arthroplasty. J Arthroplasty 2005; 20(8)1084–8
- Ducheyne P, De Meester P, Aernoudt E, Martens M, Mulier J C. Fatigue failure of the femoral component of Charnley and Charnley-Muller type total hip prostheses. J Biomed Mater Res Symp 1975; 6: 199–219
- Galante J O, Rostoker W, Doyle J M. Failed femoral stems in total hip prostheses. J Bone Joint Surg (A) 1975; 57: 230–6
- Gilbert J, Buckley C, Jacobs J. Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants. J Bone Joint Surg (Am) 1994; 76: 110–115
- Lee G W, Kim H T. Early fatigue failures of cemented, forged, cobalt-chromium femoral stems at the neck-shoulder junction. J Arthroplasty 2001; 16: 236
- Lieberman J, Rimnac C, Garvin K. An analysis of the head-neck taper interface in retrieved hip prostheses. Clin Orthop 1994, 300: 162–7
- McLaughlin J R, Lee K R. The outcome of total hip replacement in obese and non-obese patients at 10- to 18-years. J Bone Joint Surg (Br) 2006; 88: 1286–92
- Swarts E, Miller S, Keogh C V. Lim G, Beaver R. Fractured Whiteside Ortholoc II knee components. J Arthroplasty 2001; 16(7)927–34
- Vatani N, Comando D, Acuna J. Faulty design increases the risk of neck fracture in a hip prosthesis. Acta Orthop Scand 2002; 73(5)513–7
- Wroblewski B M. Fractured stem in total hip replacement. Acta Orthop Scand 1982; 53: 279–84
Free access
Catastrophic failure of 4 cobalt-alloy Omnifit hip arthroplasty femoral components
Reprints and Corporate Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
To request a reprint or corporate permissions for this article, please click on the relevant link below:
Academic Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
Obtain permissions instantly via Rightslink by clicking on the button below:
If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.