- Aspenberg P, Goodman S, Toksvig-Larsen S, Ryd L, Albrektsson T. Intermittent micromotion inhibits bone ingrowth. Titanium implants in rabbits. Acta Orthop Scand 1992; 63(2)141–5
- Carlson L, Rostlund T, Albrektsson B, Albrektsson T. Implant fixation improved by close fit. Cylindrical implant-bone interface studied in rabbits. Acta Orthop Scand 1988; 59(3)272–5
- Gausepohl T, Mohring R, Pennig D, Koebke J. Fine thread versus coarse thread. A comparison of the maximum holding power. Injury (Suppl 4) 2001; 32: SD1–7
- Lawes T J, Goodship A E. Cortical profile external fixation screws maintain torque in the metaphysis. J Bone Joint Surg (Br) (Suppl 3) 1997; 79: 370
- Lawes T J, Scott J C, Goodship A E. Increased insertion torque delays pin-bone interface loosening in external fixation with tapered bone screws. J Orthop Trauma 2004; 18(9)617–22
- Magyar G, Toksvig-Larsen S, Moroni A. Hydroxyapatite coating of threaded pins enhances fixation. J Bone Joint Surg (Br) 1997; 79(3)487–9
- Magyar G. Osteotomy for gonarthrosis - with special references to the tibial callus distraction technique. Thesis. Department of Orthopedics, University Hospital, Lund, Lund University 1999
- Merolli A, Moroni A, Faldini C, Tranquilli Leali P, Giannini S. Histomorphological study of bone response to hydroxyapatite coating on stainless steel. J Mater Sci Mater Med 2003; 14(4)327–33
- Moroni A, Aspenberg P, Toksvig-Larsen S, Falzarano G, Giannini S. Enhanced fixation with hydroxyapatite coated pins. Clin Orthop 1998, 346: 171–7
- Moroni A, Faldini C, Marchetti S, Manca M, Consoli V, Giannini S. Improvement of the bone-pin interface strength in osteoporotic bone with use of hydroxyapa-tite-coated tapered external-fixation pins. A prospective, randomized clinical study of wrist fractures. J Bone Joint Surg (Am) 2001; 83(5)717–21
- Soballe K. Hydroxyapatite ceramic coating for bone implant fixation. Mechanical and histological studies in dogs Acta Orthop Scand (Suppl 255) 1993; 1–58
- Wikenheiser M A, Markel M D, Lewallen D G, Chao E Y. Thermal response and torque resistance of five cortical half-pins under simulated insertion technique. J Orthop Res 1995; 13(4)615–9
Free access
Inferior fixation with a new pin design for external fixation: A randomized study in 50 patients operated on by the hemicallotasis technique
Reprints and Corporate Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
To request a reprint or corporate permissions for this article, please click on the relevant link below:
Academic Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
Obtain permissions instantly via Rightslink by clicking on the button below:
If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.