A new approach for assessment of wear in metal-backed acetabular cups using computed tomography: A phantom study with retrievals

, , , &
Pages 218-224 | Received 18 Jan 2007, Accepted 31 Jul 2007, Published online: 08 Jul 2009

  • Bland J M, Altman D G. Statistical methods for assessing agreement between two methods of clinical measurements. The Lancet 1986; 1(8476)307–10
  • Clarke I C, Black K, Rennie C, Amstutz H C. Can wear in total hip arthroplasties be assessed from radiographs?. Clin Orthop 1976, 121: 126–42
  • Devane P A, Horne G, Martin K, Coldham G, Krause B. Three-dimensional polyethylene wear of a press-fit titanium prosthesis. J Arthroplasty 1997; 12(3)256–66
  • Gorniak R J T, Kramer E L, Maguire G Q J, Noz M E, Schettino C J, Zeleznik M P. Evaluation of a semi-automatic 3D fusion technique applied to molecular imaging and MRI brain/frame volume data sets. J Med Syst 2003; 27(2)141–56
  • Isaac G H, Dowson D, Wroblewski B M. An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cups-wear, creep or degradation. Proc Inst Mech Eng 1996; 210: 209–16
  • ISO. Accuracy (trueness and precision) of measurement. International standard ISO. Switzerland 1998; 5725–1: 1994
  • Kabo J M, Gebhard J S, Loren G, Amstutz H C. In vivo wear of polyethylene acetabular components. J Bone Joint Surg (Br) 1993; 75(2)254–8
  • Kärrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J. Radiostereometry of hip prostheses: Review of methodology and clinical results. Clin Orthop 1997, 344: 94–110
  • Lewis G, Fencl R M, Caroll M, Collins T. The relative influence of five variables on the in vitro wear rate of uncross-linked UHMWPE acetabular liners. Biomaterials 2003; 24: 1925–35
  • Maguire G Q J, Noz M E, Rusinek H, Jaeger J, Kramer E L, Sanger J J, Smith G. Graphics applied to image registration. IEEE Computer Graphics Appl 1991; 11: 20–9
  • Martell J M, Berkson E, Berger R, Jacobs J. Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty. J Bone Joint Surg (Am) 2003a; 85(6)1111–7
  • Martell J M, Verner J J, Incavo S J. Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: A randomized prospective trial. J Arthroplasty (7 Suppl 1) 2003b; 18: 55–9
  • Mohanty M. Cellular basis for failure of joint prosthesis. Bio Med Mater Eng 1996; 6: 165–72
  • Noz M E, Maguire G Q J, Zeleznik M P, Kramer E L, Mahmoud F, Crafoord J. A versatile functional-anatomic image fusion method for volume data aets. J Med Syst 2001; 25: 297–307
  • Olivecrona L, Crafoord J, Olivecrona H, Noz M E, Maguire G Q J, Zeleznik M P, Svensson L, Weidenhielm L. Acetabular component migration in total hip arthroplasty using CT and a semi-automated program for volume merging. Acta Radiol 2002; 43: 517–27
  • Olivecrona H, Olivecrona L, Weidenhielm L, Stark A, Noz M E, Maguire G Q J, Zeleznik M P, Svensson L, Jonson T. Stability of acetabular axis after total hip arthroplasty. Repeatability using CT and a semiautomated program for volume fusion. Acta Radiol 2003a; 44: 653–61
  • Olivecrona H, Weidenhielm L, Olivecrona L, Noz M E, Maguire G Q J, Zeleznik M P, Svensson L, Jonson T. Spatial component position in total hip arthroplasty. Accuracy and repeatability with a new CT method. Acta Radiol 2003b; 44: 84–91
  • Olivecrona L, Olivecrona H, Weidenhielm L, Noz M E, Maguire J R G Q, Zeleznik M P. Model studies on acetabular component migration in total hip arthroplasty using CT and a semi-automated program for volume merging. Acta Radiol 2003c; 44: 419–29
  • Olivecrona H, Weidenhielm L, Olivecrona L, Beckman M O, Stark A, Noz M E, Maguire J R G Q, Zeleznik M P, Svensson L, Jonson T. A new CT method to measure cup orientation after Total Hip Arthroplasty. A study on 10 patients. Acta Orthop Scand 2004; 75: 253–60
  • Olivecrona L, Jedenmalm A, Aspelin P, Weidenhielm L, Noz M E, Maguire J R G Q, Zeleznik M P, Olivecrona H. Assessing wear of the acetabular cup using computed tomography: an ex vivo study. Acta Radiol 2005; 46: 852–7
  • Ranstam J, Ryd L, Onsten I. Accurate accuracy assessment. Review of basic principles. Acta Orthop Scand 2000; 71(1)106–8
  • Revell P A, Al-Saffar N, Kobayashi A. Biological reaction to debris in relation to joint prostheses. Proceedings of the Institution of Mechanical Engineers. Part H. J Eng Med 1997; 211: 187–97
  • Schewelov T, Sanzén L, Bürlin N, Markusson P, Önsten I. Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: an experimental study. Acta Orthop Scand 2004; 75(6)691–700
  • Sochart D H. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop 1999, 363: 135–50
  • Sychterz C J, Engh C A, Shah N, Engh C A. Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time. J Bone Joint Surg (Am) 1997; 79: 1040–6

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.