- Aspenberg P. Wear and osteolysis in total joint replacements. Acta Orthop Scand 1998; 69(4)435–6
- Berry D J, von Knoch M, Schleck C D, Harmsen W S. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg (Am) 2005; 87(11)2456–63
- Carlsson A S, Nilsson J A, Blomgren G, Josefsson G, Lind-berg L T, Onnerfalt R. Low- vs high‐viscosity cement in hip arthroplasty. No radiographic difference in 226 arthro‐sis cases followed for 5 years. Acta Orthop Scand 1993; 64(3)257–62
- Clarke I C, Good V, Anissian L, Gustafson A. Charnley wear model for validation of hip simulators‐ball diameter versus polytetrafluoroethylene and polyethylene wear. Proc Inst Mech Eng [H] 1997; 211(1)25–36
- Digas G, Thanner J, Nivbrant B, Rohrl S, Strom H, Kar-rholm J. Increase in early polyethylene wear after sterilization with ethylene oxide: radiostereometric analyses of 201 total hips. Acta Orthop Scand 2003; 74(5)531–41
- Glant T T, Jacobs J J, Molnar G G, Shanbhag A S, Valyon M, Galante J O. Bone resorption activity of particulate‐stimulated macrophages. J Bone Miner Res 1993; 8(9)1071–9
- Howie D W, Vernon-Roberts B, Oakeshott R, Manthey B. A rat model of resorption of bone at the cement‐bone interface in the presence of polyethylene wear particles. J Bone Joint Surg (Am) 1988; 70(2)257–63
- Howie D W, Manthey B, Hay S, Vernon-Roberts B. The synovial response to intraarticular injection in rats of polyethylene wear particles. Clin Orthop 1993, 292: 352–7
- Ilchmann T, Reimold M, Müller-Schauenburg W. Estimation of the wear volume after total hip replacement. A simple access to geometricla concepts. Med Eng Phys 2008; 30(3)373–9
- Jasty M, Goetz D D, Bragdon C R, Lee K R, Hanson A E, Elder J R, Harris W H. Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty‐eight components retrieved at autopsy or revision operations. J Bone Joint Surg (Am) 1997; 79(3)349–58
- Kesteris U, Ilchmann T, Wingstrand H, Onnerfalt R. Polyethylene wear in Scanhip arthroplasty with a 22 or 32 mm head: 62 matched patients followed for 7-9 years. Acta Orthop Scand 1996; 67(2)125–7
- Kesteris U, Robertsson O, Wingstrand H, Onnerfalt R. Cumulative revision rate with the Scan Hip Classic I total hip prosthesis. 1,660 cases followed for 2-12 years. Acta Orthop Scand 1998; 69(2)133–7
- Kesteris U, Jonsson K, Robertsson O, Onnerfalt R, Wingstrand H. Polyethylene wear and synovitis in total hip arthroplasty: A sonographic study of 48 hips. J Arthroplasty 1999; 14(2)138–43
- Kesteris U, Hardinge K, Ilchmann T, Wingstrand H. Polyethylene wear in prosthetic hips with loose components. J Arthroplasty 2003; 18(1)10–5
- Linder L. Implant stability, histology, RSA and wear—more critical questions are needed. A view point. Acta Orthop Scand 1994; 65(6)654–8
- Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg (Am) 1990; 72(4)518–28
- Malchau H, Herberts P, Eisler T, Garellick G, Soderman P. The Swedish Total Hip Replacement Register. J Bone Joint Surg (Am) (Suppl 2) 2002; 84: 2–20
- Manley M T, D'Antonio J A, Capello W N, Edidin A A. Related Articles, Osteolysis: a disease of access to fixation interfaces. Clin Orthop 2002, 405: 129–37
- Marston R A, Cobb A G, Bentley G. Stanmore compared with Charnley total hip replacement. A prospective study of 413 arthroplasties. J Bone Joint Surg (Br) 1996; 78(2)178–84
- Murray D W, Rushton N. Macrophages stimulate bone resorption when they phagocytose particles. J Bone Joint Surg (Br) 1990; 72(6)988–92
- Robertsson O, Wingstrand H, Kesteris U, Jonsson K, Onnerfalt R. Intracapsular pressure and loosening of hip prostheses. Preoperative measurements in 18 hips. Acta Orthop Scand 1997; 68(3)231–4
- Rohrl S M, Nivbrant B, Strom H, Nilsson K G. Effect of augmented cup fixation on stability, wear, and osteolysis: a 5-year follow‐up of total hip arthroplasty with RSA. J Arthroplasty 2004; 19(8)962–71
- Schmalzried T P, Jasty M, Harris W H. Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg (Am) 1992; 74(6)849–63
- Sundfeldt M, Carlsson L V, Johansson C B, Thomsen P, Gretzer C. Aseptic loosening, not only a question of wear: a review of different theories. Acta Orthop 2006; 77(2)177–97
- Tarasevicius S, Kesteris U, Robertsson O, Wingstrand H. Femoral head diameter affects the revision rate in total hip arthroplasty: An analysis of 1,720 hip replacements with 9-21 years follow‐up. Acta Orthop 2006; 77(5)706–9
- Tarasevicius S, Kesteris U, Kalesinskas R J, Wingstrand H. Dynamics of hip joint effusion after posterior soft tissue repair in total hip arthroplasty. Int Orthop 2006b; 30(4)233–6
- Van Der Vis H M, Marti R K, Tigchelaar W, Schuller H M, Van Noorden CJ. Benign cellular responses in rats to different wear particles in intra‐articular and intramedullary environments. J Bone Joint Surg (Br) 1997; 79(5)837–43
- Walter W L, Walter W K, O'Sullivan M. The pumping of fluid in cementless cups with holes. J Arthroplasty 2004; 19(2)230–4
- Zahiri C A, Schmalzried T P, Szuszczewicz E S, Amstutz H C. Assessing activity in joint replacement patients. J Arthroplasty 1998; 13: 890–5
Free access
Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty: A sonographic and radiographic study of 39 patients
Reprints and Corporate Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
To request a reprint or corporate permissions for this article, please click on the relevant link below:
Academic Permissions
Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?
Obtain permissions instantly via Rightslink by clicking on the button below:
If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.