832
Views
3
CrossRef citations to date
0
Altmetric
Original Article

Motion of the bipolar hip prosthesis components

Friction studied in cadavers

, , &
Pages 648-652 | Accepted 03 Aug 1992, Published online: 24 Nov 2009

References

  • Bateman J E. Single assembly total hip prosthesis preliminary report. Orthop Digest 1974; 2(1)15–22
  • Charnley J. Low friction arthroplasty of the hip: Low friction principle. Springer Verlag, Berlin 1979
  • Chen S C, Sarkar S, Pell L H. A radiological study of the movements of the two components of the Monk prosthesis (hard top ‘duo pleet’) in patients. Injury 1980; 12(3)243–9
  • Devas M, Hinves B. Prevention of acetabular erosion after hemiarthroplasty for fractured neck of femur. J Bone Joint Surg (Br) 1983; 65(5)548–51
  • Drinker H, Murray W R. The universal proximal femoral endoprosthesis. A short term comparison with conventional hemiarthroplasty. J Bone Joint Surg (Am) 1979; 61(8)1167–74
  • Eiskær S, Boll K, Gelineck J. Component motion in bipolar cemented hemiarthroplasty. J Orthop Trauma 1989; 3(4)313–6
  • Gilberty R P. A new concept of bipolar endoprosthesis. Orthop Rev 1974; 3(1)40–5
  • Krein S W, Chao E Y. Biomechanics of bipolar hip endoprostheses. J Orthop Res 1984; 2(4)356–68
  • Lestrange N R. Bipolar arthroplasty for 496 hip fractures. Clin Orthop 1990; 251: 7–19
  • Long J W, Knight W. Bateman UPF prosthesis in fractures of the femoral neck. Clin Orthop 1980; 152: 198–201
  • Mabuchi K, Tsukamoto Y, Tokita M, Sasada T. Damping pattern of an oscillating pendulum supported by a squeezed film lubricated bearing. J JSLE Internal Ed. 1984; 5: 59–64
  • Mabuchi K, Sasada T. Numerical analysis of elastohydrodynamic squeeze film lubrication of total hip prosthesis. Wear 1990; 140(1)116
  • Mess D, Barmada R. Clinical and motion studies of the Bateman bipolar prosthesis in osteonecrosis of the hip. Clin Orthop 1990; 251: 44–7
  • Phillips T W. The Bateman bipolar femoral head replacement. A fluoroscopic study of movement over a four year period. J Bone Joint Surg (Br) 1987; 69(5)761–4
  • Schildhaus A IE. The Bateman universal femoral aasembly: Experiences with 80 cases. Orthopedics 1980; 3(8)974–80
  • Tsukamoto Y, Yamamoto M, Mabuchi K, Morita M, Sasada T. Boundary lubricating property of synovial fluid on artificial material and lubrication of artificial joints. Nippon Seikeigeka Gakkai Zasshi 1983; 57(1)91–9
  • Tsukamoto Y, Miwa K, Imai T, Itoman M, Futami T, Mabuchi K. The motion and clinical results of bipolar hip prosthesis. Read at the 61st Meeting of Japanese Orthopaedic Association, KyotoJapan, 1988
  • Unsworth A, Dowson D, Wright V, Koshal D. The frictional behavior of human synovial joints part II: Artificial joints. J Lubr Technol 1975; 97(3)377–81
  • Verbeme G H. A femoral head prosthesis with a built in joint. A radiological study of the movements of the two components. J Bone Joint Surg (Br) 1983; 65(5)544–7

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.