287
Views
66
CrossRef citations to date
0
Altmetric
Research Article

Guidelines and recommendations for safe use of Doppler ultrasound in perinatal applications

&
Pages 75-84 | Published online: 07 Jul 2009

References

  • Barnett SB, Kossoff G, eds. Safety of Diagnostic Ultrasound. Progress in Obstetrics and Gynecological Sonography Series. Carnforth, UK: Parthenon Publishing, 1998
  • ter Haar GR, Duck FA. The Safe Use of Ultrasound in Medical Diagnosis. London: BritishMedicalUltrasoundSociety/British Institute of Radiology, 2000
  • Barnett SB, ter Haar GR, Ziskin MC, Nyborg WL, Maeda K, Bang J. Current status of research on biophysical effects of ultrasound. Ultrasound Med Biol 1994;20:205–18
  • Duck FA, HendersonJ.Acousticoutputof modernultrasound equipment: is it increasing? In Barnett SB, Kossoff G, eds. Safety of Diagnostic Ultrasound. Carnforth, UK: Parthenon Publishing, 1998:15–25
  • Henderson J, Willson K, Jago JR, Whittingham TA. A survey of the acoustic outputs of diagnostic ultrasound equipment in current clinical use. Ultrasound Med Biol 1995;21:699–705
  • Henderson J, Whittingham TA, Dunn T. A review of the acoustic output of modern diagnostic ultrasound equipment. BMUS Bull 1997; November: 10–14
  • Barnett SB, Rott HD,TerHaar GR,Ziskin MC,Maeda K. The sensitivity of biological tissue to ultrasound. Ultrasound Med Biol 1997;23:805–12
  • Barnett SB, Kossoff G, eds. WFUMB World Federation for Ultrasound in Medicine and Biology Third Symposium in Medical Ultrasound. Issues and recommendations regarding thermal mechanisms for biologicaleffectsof ultrasound. Ultra- sound Med Biol 1992;18:733–7
  • Maulik D, Figueroa R, SicuranzaG, Garry D. Dopplerfetalsur- veillance in clinical practice: evidence based guidelines for 1998. J Fertil Reprod 1998;2:5–6
  • Benacerraf BR. Should sonographic screening for fetal Down syndrome be applied to low risk women? Ultrasound Obstet Gynecol 2000;15:451–5
  • Duck FA. Physical Properties of Tissue: a Comprehensive Refer- ence Book. London: Academic Press, 1990
  • NCRP. Exposure Criteria for Medical Diagnostic Ultrasound: 1. Criteria Based on Thermal Mechanisms. Report no. 113. Bethesda,MD:NationalCouncilforRadiationProtectionand Measurements, 1992
  • Horder MM, Barnett SB, Vella GJ, Edwards MJ, Wood AKW. Ultrasound-induced temperature increase in the guinea pig fetal brain in utero: third-trimester gestation. Ultrasound Med Biol 1998;24:1501–10
  • Horder MM, Barnett SB, Vella GJ, Edwards MJ, Wood AKW. In vivo heating of the guinea-pig fetal brain by pulsed ultra- sound and estimates of Thermal Index. Ultrasound Med Biol 1998;24:1467–74
  • Barnett SB, Edwards MJ, Martin P. Pulsed ultrasoundinduces temperature elevation and nuclear abnormalities in bone marrow cells of guinea pig femurs. Proceedings of the 6th World Congress on Ultrasound Medicine no. 3405, Copenhagen, Denmark. WFUMB, 1991
  • Angles JM, Walsh DA, Li K, Barnett SB, Edwards MJ. Effects of pulsed ultrasound and temperature on the development of rat embryos in culture. Teratology 1990;42:285–93
  • Barnett SB, Walsh DA, Angles JA. Novel approachto evalu- ate the interaction of pulsed ultrasound with embryonic development. Ultrasonics 1990;28:166–70
  • Leighton TG. The Acoustic Bubble. London: Academic Press, 1994
  • NCRP. BiologicalEffectsof Ultrasound: MechanismsandClinical Implications. Report 74. Bethesda, MD: National Council on Radiation Protection and Measurements, 1983
  • Child SZ, Hartman CL, Schery LA, Carstensen EL. Lung damage from exposure to pulsed ultrasound. Ultrasound Med Biol 1990;16:817–25
  • Tarantal AF, Canfield DR. Ultrasoundinduced lung haemor- rhage in the monkey. Ultrasound Med Biol 1994;20:65–72
  • Holland CK, Deng CX, Apfel RE, Alderman JL, Fernandez LA, Taylor KJW. Direct evidence of cavitation in vivo from diagnostic ultrasound. Ultrasound Med Biol 1996;22:917–25
  • Raeman CH, Child SZ, Dalecki D, Cox C, Carstensen EL. Exposure time dependence of the threshold for ultrasonically induced murine lung haemorrhage. UltrasoundMed Biol 1996; 22:139–41
  • Duck FA. Acoustic streaming and radiation pressure in diag- nostic applications: what are the implications? In Barnett SB, Kossoff G, eds. Safety of Diagnostic Ultrasound. Carnforth, UK: Parthenon Publishing, 1998:87–98
  • Newnham JP, Evans SF, Michael CA, Stanley FJ, Landau LI. Effects of frequent ultrasound during pregnancy: a randomised controlled trial. Lancet 1993;2:887–91
  • Geschwind N, Galaburda AM. Cerebral lateralization. Bio- logical mechanisms, associations, and pathology. 1. A hypo- thesisand a programforresearch. ArchNeurol1985;42:428–59
  • Salvesen KA, Vatten LJ, Eik-Nes SH, Hugdahl K, Bakketeig LS. Routine ultrasonographyin utero and subsequent handed- ness and neurological development. Br Med J 1993;307:159–64
  • Kieler H, Axelsson O, Haglund B, Nilsson S, Salvesen KA. Routine ultrasoundscreeningin pregnancyand children’s sub- sequent handedness. Early Human Dev 1998;50:233–45
  • FDA. 510(k) Guide for Measuring and Reporting Acoustic Out- put of Diagnostic Ultrasound. Rockville, MD: Food and Drug Administration Centre for Devices and Radiological Health, 1992
  • Duck FA, StarrittHC, Anderson SP. A survey of the acoustic output of ultrasonic Doppler equipment. Clin Phys Physiol Meas 1987;8:39–49
  • AIUM Bioeffects Committee of the American Institute of Ultrasound in Medicine. Safety Considerations for Diagnostic Ultrasound. Rockville Pike, MD: AIUM Publications,1991
  • Barnett SB, ed. WFUMB World Federationfor Ultrasoundin MedicineandBiologySymposiumonUltrasoundinMedicine. Conclusions and recommendations on thermal and non- thermal mechanisms for biologicaleffects of ultrasound. Ultra- sound Med Biol 1998;24:1–55
  • AIUM/NEMA. Standard for Real-Time Display of Thermal and Mechanical Acoustic Output Indices on Diagnostic Ultrasound Equipment. Rockville, MD: American Institute of Ultrasound in Medicine, 1992
  • FDA. Revised 510(k)DiagnosticUltrasoundGuidance for 1993. Rockville, MD: Centre for Devices and Radiological Health, US Food and Drug Administration, 1993
  • American Institute of Ultrasound in Medicine. Medical Ultra- sound Safety. Rockville,MD: AIUM Publications, 1994 36. AIUM Newsletter, vol. 15, Jan. 1998

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.