Implantable rhythm devices and electromagnetic interference: myth or reality?

&
Pages 823-832 | Published online: 10 Jan 2014

References

  • Pinski SL, Trohman RG. Interference in implanted cardiac devices. Part 1. PACE25(9), 1367–1381 (2002).
  • Sweesy MW. Understanding electromagnetic interference. Heart Rhythm4, 523–524 (2004).
  • Santomauro M, Da Prato D, Ottaviano L, Borrelli A, Chiarello M. Recommendations for the protection against electromagnetic interference risk caused by pacemakers and implantable defibrillators in hospitals. Ital. Heart J. Suppl.3, 440–445 (2002).
  • Trigano A, Blandeau O, Souques M, Genez JP, Magne I. Clinical study of interference with cardiac pacemakers by a magnetic field at power line frequencies. J. Am. Coll. Cardiol.45, 896–900 (2005).
  • Luechinger R, Duru F, Zeijlemaker VA, Scheidegger MB, Boesiger P, Candinas P. Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: are reed switches always closed in strong magnetic fields? Pacing Clin. Electrophysiol.25, 1419–1423 (2002).
  • Pinski SL. Trohman RG, Interference in implanted cardiac devices. Part II. PACE25(9), 1496–1509 (2002).
  • Martin ET, Can cardiac pacemakers and magnetic resonance imaging systems co-exist? Eur. Heart J.26, 325–327 (2005).
  • Schmiedel A, Hackenbroch M, Reinke M et al. Magnetic resonance imaging of the brain at 1.5 Tesla in patients with cardiac pacemakers: can it be done? J. Card. Magn. Reson.2, 39–40 (2002).
  • Valhaus C, Sommer T, Lewalter T et al. Interference with cardiac pacemakers by magnetic resonance imaging: are there reversible changes at 0.5 Tesla? PACE24, 489–495 (2001).
  • Avery E. Loss prevention case of the month. Not my responsibility! J. Tenn. Med. Assoc.81, 523 (1988).
  • Schiebler M, Kaut-Watson C, Williams D. Both sedated and critically ill require monitoring during MRI survey. MR41–45 (1994).
  • Coman JA, Martin ET, Ramza BM, Margolis PD, Fair RD. Pacemaker safety during magnetic resonance imaging at 1.5T. J. Am. Coll. Cardiol.37(Suppl. A), 436 (2001).
  • Pohost GM, Blackwell GG, Shellock FG. Safety of patients with medical devices during application of magnetic resonance methods. Ann. NY Acad. Sci.649, 302–312 (1992).
  • Gimbel JR, Wilkoff BL, Kanal E, Rozner MA. Safe, sensible, sagacious: responsible scanning of pacemaker patients. Eur. Heart J.26, 1683–1691 (2005).
  • Irnich W, Irnich B, Bartsch C et al. Do we need pacemakers resistant to magnetic resonance imaging? Europace7, 353–365 (2005).
  • Martin ET, Coman JA, Shellock FG et al. Magnetic resonance imaging and cardiac pacemaker safety at 1.5 Tesla. J. Am. Coll. Cardiol.43(7), 1315–1324 (2004).
  • Sommer T, Naehle CP, Yang A et al. Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5T in the presence of cardiac pacemakers in non-pacemaker dependent patients. Circulation114(12), 1285–1292 (2006).
  • Yerra L, Reddy PC. Effects of electromagnetic interference on implanted cardiac device and their management. Cardiol. Rev.15, 304–309 (2007).
  • Naehle CP, Sommer T, Meyer C et al. Strategy for safe performance of magnetic resonance imaging on a patient with implantable cardioverter defibrillator. PACE29, 113–116 (2006).
  • Gimbel JR, Kanal E, Schwartz KM, Wilkoff BL. Outcome of magnetic resonance imaging in selected patients with implantable cardioverter defibrillators. PACE28, 270–273 (2005).
  • Roguin A, Zviman MM, Meiniger GR et al. Modern pacemakers and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe. Circulation110, 475–482 (2004).
  • Kiski R, Matsumoto N, Nakazawa K et al. Influence of mobile magnetic resonance imaging on implanted pacemakers. PACE26, 527–529 (2003).
  • Kusumoto FM, Pedersen S, Golschlager N. Environmental Effects on Cardiac Pacing Systems. Cardiac Pacing for the Clinician. Lippincott Williams and Wilkins, PA, USA, 377–394 (2001).
  • Sundar S, Symonds RP, Deehan C. Radiotherapy to patients with artificial cardiac pacemakers. Cancer Treat. Rev.31, 474–486 (2005).
  • Hurkmans CW, Scheepers E, Springorum BG et al. Influence of radiotherapy on the latest generation of pacemakers. Radiother. Oncol.76, 93–98 (2005).
  • Hurkmans CW, Scheepers E, Springorum BG, et al. Influence of radiotherapy on the latest version of implantable cardioverter–defibrillator. Int. J. Radiat. Oncol. Biol. Phys.63, 282–289 (2005).
  • Solan AN, Solan MJ, Bednarz G, Goodkin MB. Treatment of patients with cardiac pacemakers and implantable cardiovertor defibrillators during radiotherapy. Int. J. Radiat. Oncol. Biol. Phys.59(3), 897–904 (2004).
  • Marbach JR, Sontag MR, Van Dyk J, Wolbarst AB. Management of radiation oncology patients with implanted cardiac pacemakers: report of APPM Task Group No 34. Medical Physics21(1), 85–90 (1994).
  • Altamura G, Bianconi L, Lo Bianco F et al. Transthoracic DC shock may represent a serious hazard in pacemaker dependent patients. PACE18(1), 194–198 (1995).
  • Proclemer A, Facchin D, Pagnutti C et al. Safety of pacemaker implantation prior to radiofrequency ablation of atrioventricular junction is a single session procedure. PACE23, 998–1002 (2000).
  • Pfeiffer B, Tebbenjohanns J, Schumacher B et al. Pacemaker function during radiofrequency catheter ablation. PACE18, 1037–1044 (1995).
  • Erdogan O. Electromagnetic interference on pacemakers, Brief review. Indian Pacing Electrophysiol. J.2(3), 74–78 (2002).
  • VanHemel NM, Hamerlijnk RP, Pronk KJ, et al. Upper limit ventricular stimulation in respiratory rate responsive pacing due to electrocautery. Pacing Clin. Electrophysiol.12, 1720–1723 (1989).
  • Irnich W. Interference in pacemakers. PACE1021–1048 (1984).
  • Albers DD, Lybrand FE III, Axton JC et al. Shockwave lithotripsy and pacemakers: experience of 20 cases. J. Endourol.9, 301–303 (1995).
  • Chung MK, Streem SB, Ching E et al. Effects of extracorporeal shock wave litotripsy on tiered therapy implantable cardioverter defibrillator. PACE22, 738–742 (1999).
  • Dubner S, Dubner Y, Gallino S et al. Electromagnetic interference with implantable cardiac pacemakers by video capsule. Gastrointest. Endosc.61, 205–204 (2005).
  • Bandorski D, Irnich W, Bruck M et al. Capsule endoscopy and cardiac pacemakers: investigation for possible interference. Endoscopy40, 36–39 (2008).
  • Dubner S, Dubner Y, Rubio H, Goldin E. Electromagnetic interference from wireless video-capsule endoscopy on implantable cardioverter defibrillators. PACE30, 472–475 (2007).
  • Rasmussen MJ, Hayes DL, Vliestra RE et al. Can transcutaneous electrical nerve stimulation be safely used in patients with permanent pacemakers? Mayo Clin. Proc.63, 443 (1988).
  • Holmgren C, Carlsson T, Mannheimer C, Edvarsson N. Risk of interference from transcutaneous electrical nerve stimulation on the sensing function of implantable defibrillators. PACE31, 151–158 (2008).
  • Hayes DL, Wabg PJ, Reynolds DW et al. Interference with cardiac pacemakers by cellular telephones. N. Engl. J. Med.336, 1473–1479 (1997).
  • Trigano A, Blandeau O, Dale C, Wong MF, Wiart J. Reliability of electromagnetic filters of cardiac pacemakers tested by cellular telephone ringing. Heart Rhythm2(8), 837–841 (2005).
  • Bassen HI, Moore HJ, Ruggers PS. Cellular phone interference testing of implantable cardiac defibrillators in-vitro. PACE21, 1709–1715 (1998).
  • Tandogan I, Ozin B, Bozbas H et al. Effects of mobile telephones on the function of implantable cardioverter defibrillators. Ann. Noninvasive Electrocardiol.10(4), 409–413 (2005).
  • Tri JL, Trusty JM, Hayes DL. Potential for personal digital assistant interference with implantable cardiac devices. Mayo Clin. Proc.79(12), 1527–1530 (2004).
  • Patel MB, Thaker JP, Punnam S. Jongnarangsin K. Pacemaker interference with an iPod. Heart Rhythm4(6), 781–784 (2007).
  • Basse H. Low frequency magnetic emissions and resulting induced voltages in a pacemaker by iPod portable music players. Biomed. Eng. Online7(1), 7 (2008).
  • Carillo R, Stevenson R. iPods and pacemakers: no clinically significant electromagnetic interference. Abstract submitted for: Heart Rhythm Society Meeting 2008. San Francisco, CA, USA, 14–17 May, 2008.
  • Wolber T, Salome R, Binggeli C et al. Potential interference of small neodymium magnets with pacemakers and implantable cardioverter-defibrillators. Heart Rhythm4(1), 1–4 (2007).
  • Kolb C, Schmeider S, Lehmann G et al. Do airport metal detectors interfere with implantable pacemakers or cardioverter–defibrillators? J. Am. Coll. Cardiol.41, 2054–2059 (2003).
  • Chan NY, Ho LWL. Inappropriate implantable cardioverter–defibrillator shock due to external alternating current leak: Report of 2 cases. Eurospace7, 193–196 (2005).

Website

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.