References
- Resnikoff S, Pascolini D, Etya’ale D et al. Global data on visual impairment in the year 2002. Bull. World Health Organ. 82(11), 844–851(2004).
- Weinreb RN, Khaw PT. Primary open-angle glaucoma. Lancet 363(9422), 1711–1720 (2004).
- Wilson MR. The myth of “21”. J. Glaucoma 6(2), 75–77 (1997).
- Weinreb RN, Brandt JD, Garway-Heath DF, Medeiros FA. Intraocular Pressure. Kugler Publications, Amsterdam, The Netherlands (2007).
- Goldmann H. Un nouveau tonometre d’applanation. Bull. Mem. Soc. Fr. Ophtalmol. 67, 474–477; discussion, 477–478 (1954).
- Whitacre MM, Stein R. Sources of error with use of Goldmann-type tonometers. Surv. Ophthalmol. 38(1), 1–30 (1993).
- Ehlers N, Bramsen T, Sperling S. Applanation tonometry and central corneal thickness. Acta Ophthalmol. (Copenh.) 53(1), 34–43 (1975).
- Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J. Cataract Refract. Surg. 31(1), 146–155 (2005).
- Liu JH, Kripke DF, Twa MD et al. Twenty-four-hour pattern of intraocular pressure in the aging population. Invest. Ophthalmol. Vis. Sci. 40(12), 2912–2917 (1999).
- Liu JH, Zhang X, Kripke DF, Weinreb RN. Twenty-four-hour intraocular pressure pattern associated with early glaucomatous changes. Invest. Ophthalmol. Vis. Sci. 44(4), 1586–1590 (2003).
- Barkana Y, Anis S, Liebmann J, Tello C, Ritch R. Clinical utility of intraocular pressure monitoring outside of normal office hours in patients with glaucoma. Arch. Ophthalmol. 124(6), 793–797 (2006).
- Mosaed S, Liu JH, Weinreb RN. Correlation between office and peak nocturnal intraocular pressures in healthy subjects and glaucoma patients. Am. J. Ophthalmol. 139(2), 320–324 (2005).
- Hattenhauer MG, Johnson DH, Ing HH et al. The probability of blindness from open-angle glaucoma. Ophthalmology 105(11), 2099–2104 (1998).
- Liu JH, Weinreb RN. Monitoring intraocular pressure for 24 h. Br. J. Ophthalmol. 95(5), 599–600 (2011).
- Liu JH, Medeiros FA, Slight JR, Weinreb RN. Comparing diurnal and nocturnal effects of brinzolamide and timolol on intraocular pressure in patients receiving latanoprost monotherapy. Ophthalmology 116(3), 449–454 (2010).
- Weinreb RN, Liu JH. Nocturnal rhythms of intraocular pressure. Arch. Ophthalmol. 124(2), 269–270 (2006).
- Mansouri K, Orguel S, Mermoud A et al. Quality of diurnal intraocular pressure control in primary open-angle patients treated with latanoprost compared with surgically treated glaucoma patients: a prospective trial. Br. J. Ophthalmol. 92(3), 332–336 (2008).
- Mansouri K, Medeiros FA, Weinreb RN. Letter to the editor: 24-h versus daytime intraocular pressure phasing in the management of patients with treated glaucoma. Br. J. Ophthalmol. 95(4), 594–595 (2011).
- Caprioli J, Varma R. Intraocular pressure: modulation as treatment for glaucoma. Am J Ophthalmol. 152(3), 340–344 (2011).
- Maurice DM. A recording tonometer. Br J Ophthalmol. 42(6), 321–335 (1958).
- Schnell CR, Debon C, Percicot CL. Measurement of intraocular pressure by telemetry in conscious, unrestrained rabbits. Invest. Ophthalmol. Vis. Sci. 37(6), 958–965 (1996).
- Akaishi T, Ishida N, Shimazaki A, Hara H, Kuwayama Y. Continuous monitoring of circadian variations in intraocular pressure by telemetry system throughout a 12-week treatment with timolol maleate in rabbits. J. Ocul. Pharmacol. Ther. 21(6), 436–444 (2005).
- Kóthy P, Vargha P, Holló G. Ocuton-S self tonometry vs. Goldmann tonometry; a diurnal comparison study. Acta Ophthalmol. Scand. 79(3), 294–297 (2001).
- Lam DS, Leung DY, Chiu TY et al. Pressure phosphene self-tonometry: a comparison with goldmann tonometry in glaucoma patients. Invest. Ophthalmol. Vis. Sci. 45(9), 3131–3136 (2004).
- Tai MC, Chen PL, Wu JN, Lu DW. Clinical evaluation of the intraocular pressure in patients with glaucoma or ocular hypertension by a self-assessable tonometer. J. Ocul. Pharmacol. Ther. 21(1), 55–61 (2005).
- Wilensky JT, Gieser DK, Mori MT, Langenberg PW, Zeimer RC. Self-tonometry to manage patients with glaucoma and apparently controlled intraocular pressure. Arch. Ophthalmol. 105(8), 1072–1075 (1987).
- Liang SY, Lee GA, Shields D. Self-tonometry in glaucoma management – past, present and future. Surv. Ophthalmol. 54(4), 450–462 (2009).
- Tarkkanen A, Ulfves K, Ulfves T. Self-tonometry in glaucoma. Graefes Arch. Clin. Exp. Ophthalmol. 248(11), 1679–1681 (2010).
- Collins CC. Miniature passive pressure transensor for implanting in the eye. IEEE Trans. Biomed. Eng. 14(2), 74–83 (1967).
- Svedbergh B, Bäcklund Y, Hök B, Rosengren L. The IOP-IOL. A probe into the eye. Acta Ophthalmol. (Copenh.) 70(2), 266–268 (1992).
- Walter P, Schnakenberg U, vom Bögel G et al. Development of a completely encapsulated intraocular pressure sensor. Ophthalmic Res. 32(6), 278–284 (2000).
- Downs JC, Burgoyne CF, Seigfreid WP, Reynaud JF, Strouthidis NG, Sallee V. 24-h IOP telemetry in the nonhuman primate: implant system performance and initial characterization of IOP at multiple timescales. Invest. Ophthalmol. Vis. Sci. 52(10), 7365–7375 (2011).
- Todani A, Behlau I, Fava MA et al. Intraocular pressure measurement by radio wave telemetry. Invest. Ophthalmol. Vis. Sci. 52(13), 9573–9580 (2011).
- Twa MD, Roberts CJ, Karol HJ, Mahmoud AM, Weber PA, Small RH. Evaluation of a contact lens-embedded sensor for intraocular pressure measurement. J. Glaucoma 19(6), 382–390 (2010).
- Leonardi M, Pitchon EM, Bertsch A, Renaud P, Mermoud A. Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes. Acta Ophthalmol. 87(4), 433–437 (2009).
- Hjortdal JO, Jensen PK. In vitro measurement of corneal strain, thickness, and curvature using digital image processing. Acta Ophthalmol. Scand. 73(1), 5–11 (1995).
- Leonardi M, Leuenberger P, Bertrand D, Bertsch A, Renaud P. First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens. Invest. Ophthalmol. Vis. Sci. 45(9), 3113–3117 (2004).
- Mansouri K, Shaarawy T. Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma. Br. J. Ophthalmol. 95(5), 627–629 (2011).
- De Smedt S, Mermoud A, Schnyder C. 24-h intraocular pressure fluctuation monitoring using an ocular telemetry sensor: tolerability and functionality in healthy subjects. J Glaucoma. doi:10.1097/IJG.0b013e31821dac43 (2011) (Epub ahead of print).
- du Toit R, Vega JA, Fonn D, Simpson T. Diurnal variation of corneal sensitivity and thickness. Cornea 22(3), 205–209 (2003).
- Kida T, Liu JH, Weinreb RN. Effect of 24-h corneal biomechanical changes on intraocular pressure measurement. Invest. Ophthalmol. Vis. Sci. 47(10), 4422–4426 (2006).
- Kida T, Liu JH, Weinreb RN. Effects of aging on corneal biomechanical properties and their impact on 24-h measurement of intraocular pressure. Am. J. Ophthalmol. 146(4), 567–572 (2008).
- Realini T, Weinreb RN, Wisniewski SR. Diurnal intraocular pressure patterns are not repeatable in the short term in healthy individuals. Ophthalmology 117(9), 1700–1704 (2010).
- Realini T, Weinreb RN, Weinreb N, Wisniewski S. Short-term repeatability of diurnal intraocular pressure patterns in glaucomatous individuals. Ophthalmology 118(1), 47–51 (2011).
- Mansouri K, Iliev ME, Rohrer K, Shaarawy T. Compliance and knowledge about glaucoma in patients at tertiary glaucoma units. Int. Ophthalmol. 31(5), 369–376 (2011).
- Mansouri K, Orgül S, Meier-Gibbons F, Mermoud A. Awareness about glaucoma and related eye health attitudes in Switzerland: a survey of the general public. Ophthalmologica. 220(2), 101–108 (2006).