Percutaneous devices: a review of applications, problems and possible solutions

, , &
Pages 389-399 | Published online: 09 Jan 2014

References

  • Tenckhoff H, Schechter H. A bacteriologically safe peritoneal access device. Trans. Am. Soc. Artif. Intern. Organs 14, 181–187 (1968).
  • von Recum AF. Applications and failure modes of percutaneous devices: a review. J. Biomed. Mater. Res. 18(4), 323–336 (1984).
  • Garvin KL, Hanssen AD. Infection after total hip arthroplasty. Past, present, and future. J. Bone Joint Surg. Am. 77(10), 1576–1588 (1995).
  • Mermel LA. Prevention of central venous catheter-related infections: What works other than impregnated or coated catheters? J. Hosp. Infect. 65(Suppl. 2), 30–33 (2007).
  • Boen ST, Mion CM, Curtis FK, Shilipetar G. Periodic peritoneal dialysis using the repeated puncture technique and an automatic cycling machine. Trans. Am. Soc. Artif. Intern. Organs 10, 409–414 (1964).
  • Ash SR. Chronic peritoneal dialysis catheters: challenges and design solutions. Int. J. Artif. Organs 29(1), 85–94 (2006).
  • Dasgupta MK. Biofilms and infection in dialysis patients. Semin. Dial. 15(5), 338–346 (2002).
  • Knabe C, Grosse-Siestrup C, Gross U. Histologic evaluation of a natural permanent percutaneous structure and clinical percutaneous devices. Biomaterials 20(6), 503–510 (1999).
  • Paquay YC, de Ruijter JE, van der Waerden JP, Jansen JA. Tissue reaction to Dacron velour and titanium fibre mesh used for anchorage of percutaneous devices. Biomaterials 17(12), 1251–1256 (1996).
  • Paquay YC, De Ruijter AE, van der Waerden JP, Jansen JA. A one stage versus two stage surgical technique. Tissue reaction to a percutaneous device provided with titanium fiber mesh applicable for peritoneal dialysis. ASAIO J. 42(6), 961–967 (1996).
  • Walboomers F, Paquay YC, Jansen JA. A new titanium fiber mesh-cuffed peritoneal dialysis catheter: evaluation and comparison with a Dacron-cuffed tenckhoff catheter in goats. Perit. Dial. Int. 21(3), 254–262 (2001).
  • Jansen JA, Walboomers XF. A new titanium fiber mesh-cuffed peritoneal dialysis catheter: an experimental animal study. J. Mater. Sci. Mater. Med. 12(10–12), 1033–1037 (2001).
  • Asoda S, Arita T, Koshitomae H, Takakuda K. Mechanical attachment of soft fibrous tissues to implants by using mesh structures. Clin. Oral Implants Res. 19(11), 1171–1177 (2008).
  • Smith TJ, Galm A, Chatterjee S et al. Modulation of the soft tissue reactions to percutaneous orthopaedic implants. J. Orthop. Res. 24(7), 1377–1383 (2006).
  • Trooskin SZ, Harvey RA, Lennard TW, Greco RS. Failure of demonstrated clinical efficacy of antibiotic-bonded continuous ambulatory peritoneal dialysis (CAPD) catheters. Perit. Dial. Int. 10(1), 57–59 (1990).
  • Trooskin SZ, Donetz AP, Baxter J, Harvey RA, Greco RS. Infection-resistant continuous peritoneal dialysis catheters. Nephron 46(3), 263–267 (1987).
  • Thurman RB, Gerba CP. The molecular mechanisms of copper and silver ion disinfection of bacteria and viruses. Crit. Rev. Env. Contr. 18(4), 295–315 (1988).
  • Fung LC, Khoury AE, Vas SI, Smith C, Oreopoulos DG, Mittelman MW. Biocompatibility of silver-coated peritoneal dialysis catheter in a porcine model. Perit. Dial. Int. 16(4), 398–405 (1996).
  • Crabtree JH, Burchette RJ, Siddiqi RA, Huen IT, Hadnott LL, Fishman A. The efficacy of silver-ion implanted catheters in reducing peritoneal dialysis-related infections. Perit. Dial. Int. 23(4), 368–374 (2003).
  • Epand RM, Epand RF, Savage PB. Ceragenins (cationic steroid compounds), a novel class of antimicrobial agents. Drug News Perspect. 21(6), 307–311 (2008).
  • Perry EL, Beck JP, Williams DL, Bloebaum RD. Assessing peri-implant tissue infection prevention in a percutaneous model. J. Biomed. Mater. Res. Part B Appl. Biomater. 92(2), 397–408 (2010).
  • van der Borden AJ, Maathuis PG, Engels E et al. Prevention of pin tract infection in external stainless steel fixator frames using electric current in a goat model. Biomaterials 28(12), 2122–2126 (2007).
  • Kantrowitz A, Freed PS, Ciarkowski AA et al. Development of a percutaneous access device. Trans. Am. Soc. Artif. Intern. Organs 26, 444–449 (1980).
  • Freed PS, Wasfie T, Bar-Lev A et al. Long-term percutaneous access device. Trans. Am. Soc. Artif. Intern. Organs 31, 230–234 (1985).
  • Gesler W, Smith R, DeDecker PG et al. Updated feasibility trial experience with the Viaderm percutaneous access device. ASAIO J. 50(4), 349–353 (2004).
  • Costerton JW. The Biofilm Primer. Springer, Heidelberg, Germany (2007).
  • Aoyama M, Mizuno T, Tatsumi E et al. An animal study of a newly developed skin-penetrating pad and covering material for catheters to prevent exit-site infection in continuous ambulatory peritoneal dialysis. Artif. Organs 33(12), 1127–1133 (2009).
  • Grosse-Siestrup C, Affeld K. Design criteria for percutaneous devices. J. Biomed. Mater. Res. 18(4), 357–382 (1984).
  • Rose EA, Gelijns AC, Moskowitz AJ et al.; Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Study Group. Long-term use of a left ventricular assist device for end-stage heart failure. N. Engl. J. Med. 345(20), 1435–1443 (2001).
  • Sivaratnam K, Duggan JM. Left ventricular assist device infections: three case reports and a review of the literature. ASAIO J. 48(1), 2–7 (2002).
  • Holman WL, Park SJ, Long JW et al.; REMATCH Investigators. Infection in permanent circulatory support: experience from the REMATCH trial. J. Heart Lung Transplant. 23(12), 1359–1365 (2004).
  • Holman WL, Kirklin JK, Naftel DC et al. Infection after implantation of pulsatile mechanical circulatory support devices. J. Thorac. Cardiovasc. Surg. 139(6), 1632–1636 (2010).
  • Opfermann U. Berlin heart incor and excor. Presented at: Mechanical Circulatory Support Symposium. Berlin, Germany, 4–6 November 2011.
  • Affeld K, Grosshauser J, Reiter K, Grosse-Siestrup C, Kertzscher U. How can we achieve infection-resistant percutaneous energy transfer? Artif. Organs 35(8), 800–806 (2011).
  • Hall CW, Cox PA, McFarland SR, Ghidoni JJ. Some factors that influence prolonged interfacial continuity. J. Biomed. Mater. Res. 18(4), 383–393 (1984).
  • Parkin JL. Percutaneous pedestal in cochlear implantation. Ann. Otol. Rhinol. Laryngol. 99(10 Pt 1), 796–800 (1990).
  • Jarvik R, Westaby S, Katsumata T, Pigott D, Evans RD. LVAD power delivery: a percutaneous approach to avoid infection. Ann. Thorac. Surg. 65(2), 470–473 (1998).
  • Westaby S, Jarvik R, Freeland A et al. Postauricular percutaneous power delivery for permanent mechanical circulatory support. J. Thorac. Cardiovasc. Surg. 123(5), 977–983 (2002).
  • Siegenthaler MP, Martin J, Gutwald R et al. Anterior approach to implant the Jarvik 2000 with retroauricular power supply. Ann. Thorac. Surg. 80(2), 745–747 (2005).
  • Westaby S, Siegenthaler M, Beyersdorf F et al. Destination therapy with a rotary blood pump and novel power delivery. Eur. J. Cardiothorac. Surg. 37(2), 350–356 (2010).
  • Schuder JC, Stephenson HE Jr, Townsend JF. Energy transfer into a closed chest by means of stationary coupling coils and a portable high-power oscillator. Trans. Am. Soc. Artif. Intern. Organs 7, 327–331 (1961).
  • Myers GH, Reed GE, Thumin A, Fascher S, Cortes L. A transcutaneous power transformer. Trans. Am. Soc. Artif. Intern. Organs 14, 210–214 (1968).
  • Shiba K, Shu E, Koshiji K et al. A transcutaneous energy transmission system with rechargeable internal back-up battery for a totally implantable total artificial heart. ASAIO J. 45(5), 466–470 (1999).
  • Puers R, Vandevoorde G. Recent progress on transcutaneous energy transfer for total artificial heart systems. Artif. Organs 25(5), 400–405 (2001).
  • Okamoto E, Yamamoto Y, Akasaka Y, Motomura T, Mitamura Y, Nosé Y. A new transcutaneous energy transmission system with hybrid energy coils for driving an implantable biventricular assist device. Artif. Organs 33(8), 622–626 (2009).
  • Dissanayake TD, Budgett DM, Hu P et al. A novel low temperature transcutaneous energy transfer system suitable for high power implantable medical devices: performance and validation in sheep. Artif. Organs 34(5), E160–E167 (2010).
  • Saito A. Development of bioartificial kidneys. Nephrology . 8, S10–S15 (2003).
  • Leonard EF. Technical approaches toward ambulatory ESRD therapy. Semin. Dial. 22(6), 658–660 (2009).
  • Leonard EF, Cortell S, Jones J. The path to wearable ultrafiltration and dialysis devices. Blood Purif. 31(1–3), 92–95 (2011).
  • Zhang T, Wei X, Bianchi G et al. A novel wearable pump-lung device: in vitro and acute in vivo study. J. Heart. Lung. Transplant. 31(1), 101–105 (2012).
  • Brånemark R, Brånemark PI, Rydevik B, Myers RR. Osseointegration in skeletal reconstruction and rehabilitation: a review. J. Rehabil. Res. Dev. 38(2), 175–181 (2001).
  • Hagberg K, Brånemark R. Consequences of non-vascular trans-femoral amputation: a survey of quality of life, prosthetic use and problems. Prosthet. Orthot. Int. 25(3), 186–194 (2001).
  • Tillander J, Hagberg K, Hagberg L, Brånemark R. Osseointegrated titanium implants for limb prostheses attachments: infectious complications. Clin. Orthop. Relat. Res. 468(10), 2781–2788 (2010).
  • Costerton JW, Cheng KJ, Geesey GG et al. Bacterial biofilms in nature and disease. Annu. Rev. Microbiol. 41, 435–464 (1987).
  • Ash SR. Chronic peritoneal dialysis catheters: procedures for placement, maintenance, and removal. Semin. Nephrol. 22(3), 221–236 (2002).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.