194
Views
38
CrossRef citations to date
0
Altmetric
Expert Opinion

Role of uterine forces in intrauterine device embedment, perforation, and expulsion

&
Pages 735-744 | Published online: 07 Aug 2014

References

  • WildemeerschDIUD/IUS designs that do not fit may significantly contribute to early discontinuation – a commentaryEur J Contracept Reprod Health Care20111613514121281098
  • HassonHMClinical studies of the Wing Sound II metrology deviceZatuchniGIGoldsmithASciarraJJIntrauterine Contraception: Advances and Future ProspectsPhiladelphia, PA, USAHarper and Row1984126141
  • KurzKHCavimeter uterine measurements and IUD clinical correlationZatuchniGIGoldsmithASciarraJJIntrauterine Contraception: Advances and Future ProspectsPhiladelphia, PA, USAHarper and Row1984142162
  • KamalIHefnawiFGhonheimMTalantMAbdallaMDimensional and architectural disproportion between the intrauterine device and the uterine cavity: a cause of bleedingFertil Steril1971225145215164979
  • GoldstuckNAssessment of uterine cavity size and shape: a systematic review addressing relevance to intrauterine procedures and eventsAfr J Reprod Health201216129138
  • GoldstuckNDThe relationship of IUD dimensions to event ratesContracept Deliv Syst1982310310512338163
  • TatumHJConnellEBIntrauterine devicesFilshieMGuillebaudJContraception: Science and PracticeLondon, UKButterworths1989
  • Van HoudenhovenKvan KaamKJAFvan GrootheestACSalemansTHBDunselmanGAJUterine perforation in women using a levonorgestrel-releasing intrauterine systemContraception20067325726016472566
  • HeartwellSFSchlesselmanSRisk of perforation among users of intrauterine devicesObstet Gynecol19836131366823347
  • GoldstuckNDHollowayGIUD insertion forces: effects of recent childbirth and lactationAdv Contracept198841591643213673
  • GoldstuckNDInsertion forces with intrauterine devices: implications for uterine perforationEur J Obstet Gynecol Reprod Biol1987253153233653495
  • AnthonyGSFisherJCouttsJRCalderAAForces required for surgical dilatation of the pregnant and non-pregnant human cervixBr J Obstet Gynaecol1982899139167171498
  • NicolaidesKHWelchCCMcPhersonMBJohnsonIRFilshieGMLamicel: a new technique for cervical dilatation before first trimester abortionBr J Obstet Gynaecol1983904754796849849
  • MilsomIAnderschBIntrauterine pressure and serum ibuprofen: observations after oral administration of 400 mg ibuprofen to a patient with primary dysmenorrhoeaEur J Clin Pharmacol1985294434464092725
  • LiedmanRSkillernLJamesIMcLeodAGrantLAkerlundMValidation of a test model of induced dysmenorrhoeaActa Obstet Gynecol Scand20068545145716612708
  • BullettiCde ZieglerDPolliVDiotalleviLDel FerroEFlamigniCUterine contractility during the menstrual cycleHum Reprod200015Suppl 1818910928421
  • CzekanowskiRDie Abhaengigkeit von Volumen un Druck in der nicht schwangeren menschlichen. [In-vitro studies into interdependence of volume and pressure in non-pregnant human uterus]Zentralbl Gynakol1980102129137 German7211025
  • TejujaSMalkaniPKClinical significance of correlation between size of the uterine cavity and IUCD: a planimeter hysterogram techniqueAm J Obstet Gynecol19691056206275824884
  • IsmailAAAnwarMYKeskSMAzaySMGaweeshSToppozadaMKUterine geometry by Wing sound and hysterography versus direct measurementsAdv Contracept198732372433673699
  • SharmaAKText Book of Vector CalculusNew Delhi, IndiaDiscovery Publishing House2006
  • D’SouzaREBoundsWGuillebaudJComparative trial of the force required for, and pain of, removing GyneFix® versus Gyne-T380S® following randomised insertionJ Fam Plann Reprod Health Care200329293112681034
  • KurzKHRole of retention in avoiding expulsion of IUDs- measuring devices for basic researchContracept Deliv Syst1982310711612338164
  • GoldstuckNDIUD fracture mechanismContraception20148932824418701
  • WilsonSTanGBaylsonMScreiberCControversies in family planning: how to manage a fractured IUDContraception20138859960324028753
  • GoldstuckNDBowing forces with IUD inserters in vitro: reference to difficult IUD insertionsClin Reprod Fertil198751731763450375
  • GiancoliDCPhysics6th edUpper Saddle River, NJ, USAPearson Prentice Hall2012
  • GoldstuckNDHofmeyrGJSonnendeckerEWButchartAIn vitro study of fracture forces associated with the Copper T, Nova T and MLCu 250/375 intrauterine devicesContraception1990415835892361369
  • HorbeltDVRobertsDKAndersonHWStudies in translocation: Dalkon shield insertion, perforation and migrationJ Kans Med Soc197980323326572391
  • CustoGSaittoCCerzaSCosmiEVIntrauterine rupture of a Multiload Cu 250 intrauterine device: report of a caseAdv Contracept198842172203071110
  • SinhaPPradhanADiabYExpulsion of part of a spontaneously broken IUDJ Obstet Gynaecol20042483783815763814
  • JindalSSharmaSSIkorniASpontaneous breakage and expulsion of a stem fragment of levonorgestrel intrauterine system (Mirena) following duplicate insertionArch Gynecol Obstet2009279959718949478
  • BraaksmaJTJanssensJEskersTKABHeinPRAccurate pressure recording in the non-pregnant human uterus. A comparison of open and closed tip cathetersEur J Obstet Gynaecol19716195206
  • Macedo-CostaLFPinto-DantasCADarzeEDe SouzaOThe effect of the IUD on the intrauterine pressure of the human uterusInt J Gynecol Obstet19719192202
  • ZakinDSternWZRosenblattRComplete and partial uterine perforation and embedding following insertion of intrauterine devices. I. Classification, complications, mechanism, incidence and missing stringObstet Gynecol Surv1981363353537029368
  • CaliskanEOzturkBDilbazODilbazSAnalysis of risk factors associated with intrauterine perforation by intrauterine devicesEur J Contracept Reprod Health Care2003815015514667326
  • GoldstuckNDA comparison of the initial pain response following insertion of the Copper 7 and combined Multiload Copper 250 IUDsContracept Deliv Syst1982229530112336990
  • WildermeerschDJanssensDAndradeAThe Femilis® LNG-IUS: contraceptive performance – an interim analysisEur J Contracept Reprod Health Care20091410311019340705
  • JohnsonNBromhamDREffect of cervical traction with a tenaculum on the uterocervical angleBr J Obstet Gynaecol1991983093122021570
  • EkeNOkpaniAOExtrauterine translocated contraceptive device: a presentation of five cases and revisit of the enigmatic issues of iatrogenic perforation and migrationAfr J Reprod Health2003711712315055154
  • Harrison-WoolrychMAshtonJCoulterDUterine perforation on intrauterine device insertion: is the incidence higher than previously reportedContraception200367535612521659
  • BenacerrafBRShippTDBromleyBThree-dimensional ultrasound detection of abnormally located intrauterine contraceptive devices which are the source of pelvic pain and abnormal bleedingUltrasound Obstet Gynecol20093411011519565532
  • Flexi-T. [homepage on the Internet] Prescribing informationProsan International BVArnhem, the Netherlands2005 Available from http://www.trimedic-inc.com/flexi-t_iud_advantage.htmlAccessed July 8, 2014
  • WildemeerschDPettAJandiSHasskampTRowePVrijensMPrecision intrauterine contraception may significantly increase continuation of use: a review of long-term clinical experience with frameless copper-releasing intrauterine contraception devicesInt J Womens Health2013521522523658502