References
- Wilson BS, Finley CC, Lawson DT, Wolford RD, Zerbi M. Design and evaluation of a continuous interleaved sampling (CIS) processing strategy for multichannel cochlear implants. J Rehabil Res Dev 1993; 30: 110–16
- Loizou P. Mimicking the human ear. IEEE Signal Processing Magazine 1998; 15: 101–30
- Loizou PC, Stickney G, Mishra L, Assmann P. Comparison of speech processing strategies used in the Clarion implant processor. Ear Hear 2003; 24: 12–19]
- Buechner A, Frohne-Buechner C, Gaertner L, Lesinski-Schiedat A, Battmer RD, Lenarz T. Evaluation of Advanced Bionics high resolution mode. Int J Audiol 2006; 45: 407–16
- Battmer, RD, Buechner, A, Boyle, P, Frohne-Buechner, C, Lenarz, T. High Resolution Mode of the Advanced Bionics Cochlear Implant System: clinical investigation of stimulation rates up to 3000 pps. Cochlear Implants Int submitted.
- Buechner A, Frohne-Buechner C, Stoever T, Gaertner L, Battmer RD, Lenarz T. Comparison of a paired or sequential stimulation paradigm with advanced bionics' high-resolution mode. Otol Neurotol 2005; 26: 941–7
- Segel, P, Voelkel, A, Faltys, M, Hartley, L, Kessler, D. The systematic evaluation of parameters in the fitting of High Resolution strategies in the Clarion Bionic Ear System. Presented at the Conference on Implantable Auditory Protheses, Asilomar, 2001.
- Arnold, L, Boyle, P. Early results on high resolution (High Resolution Mode) programming with the Soundwave fitting software. Presented at the VII International Conference on Cochlear Implants and Related Audiological Sciences, Warsaw, Poland, 2003.
- Javel E, Viemeister NF. Stochastic properties of cat auditory nerve responses to electric and acoustic stimuli and application to intensity discrimination. J Acoust Soc Am 2000; 107: 908–21
- Javel E, Shepherd RK. Electrical stimulation of the auditory nerve. III. Response initiation sites and temporal fine structure. Hear Res 2000; 140: 45–76
- Wilson, BS, Finley, CC, Lawson, DT, Zerbi, M. Temporal representations with cochlear implants. Am J Otol 1997;18(6 Suppl)S30–4
- Rubinstein, JT, Hong, R. Signal coding in cochlear implants: exploiting stochastic effects of electrical stimulation. Ann Otol Rhinol Laryngol. Suppl2003;191:14–19.
- Balkany, T, Hodges, A, Menapace, C, Hazard, L, Driscoll, C, Gantz, B, , et al. Nucleus Freedom North American clinical trial. Otolaryngol Head Neck Surg 2007;136:757–62.
- Weber, BP, Lai, WK, Dillier, N, von Wallenberg, EL, Killian, MJ, Pesch, J, , et al. Performance and preference for ACE stimulation rates obtained with nucleus RP 8 and freedom system. Ear Hear 2007;28(2 Suppl):46S–48S.
- Nie K, Barco A, Zeng FG. Spectral and temporal cues in cochlear implant speech perception. Ear Hear 2006; 27: 208–17
- Frijns JH, Klop WM, Bonnet RM, Briaire JJ. Optimizing the number of electrodes with high-rate stimulation of the clarion CII cochlear implant. Acta Otolaryngol 2003; 123: 138–42
- Loizou P, Poroy O, Dorman M. The effect of parametric variations of cochlear implant processors on speech understanding. J Acoust Soc Am 2002; 108: 790–802
- Kiefer J, v. Ilberg C, Hubner-Egner J, Rupprecht V, Knecht R. Optimized speech understanding with the continuous interleaved sampling speech coding strategy in patients with cochlear implants: effect of variations in stimulation rate and number of channels. Ann Otol Rhinol Laryngol 2000; 109: 1009–20
- Brendel, M, Büchner, A, Frohne-Büchner, C, Gärtner, L, Lenarz, T. Evaluation der Möglichkeit zur Bestimmung der optimalen Stimulationsrate über die Lautheit im HiRes-System. Proceedings of the 8. Jahrestagung der Deutschen Gesellschaft für Audiologie, Göttingen, 2005, ISBN 3-9809869-4-2.
- Büchner, A, Frohne-Büchner, C, Brendel, M, Pilsak, S, Battmer, RD, Lenarz, T. Recording the neural response while stimulating with a high rate burst. Proceedings of the Fourth International Symposium and Workshops on Objective Measures in Cochlear Implants, Hannover, 1–4, June, 2005.