References
- Richardson H. Medical laboratories – requirements for quality and competence: an ISO perspective. Vox Sang 2002; 83:s333–5.
- Howanitz PJ. Quality assurance measurements in departments of pathology and laboratory medicine. Arch Pathol Lab Med 1990;114:1131–5.
- Rattan A, Lippi G. Frequency and type of preanalytical errors in a laboratory medicine department in India. Clin Chem Lab Med 2008;46:1657–9.
- Romero A, Munoz M, Ramos JR, Campos A, Ramirez G. Identification of preanalytical mistakes in the stat section of the clinical laboratory. Clin Chem Lab Med 2005;43: 974–5.
- Shahangian S, Snyder SR. Laboratory medicine quality indicators: a review of the literature. Am J Clin Pathol 2009;131:418–31.
- Jones BA, Calam RR, Howanitz PJ. Chemistry specimen acceptability: a College of American Pathologists Q-Probes study of 453 laboratories. Arch Pathol Lab Med 1997;121: 19–26.
- Sciacovelli L, O’Kane M, Skaik YA, Caciagli P, Pellegrini C, Da Rin G, Ivanov A, Ghys T, Plebani M. Quality Indicators in Laboratory Medicine: from theory to practice. Preliminary data from the IFCC Working Group Project ‘Laboratory Errors and Patient Safety’. Clin Chem Lab Med 2011; 49:835–44.
- Zarbo RJ, Jones BA, Friedberg RC, Valenstein PN, Renner SW, Schifman RB, Walsh MK, Howanitz PJ. Q-tracks: a College of American Pathologists program of continuous laboratory monitoring and longitudinal tracking. Arch Pathol Lab Med 2002;126:1036–44.
- Joint commission releases proposed 2009 NPSGs. Healthcare Benchmarks Qual Improv 2008;15:33–5.
- Bonini P, Plebani M, Ceriotti F, Rubboli F. Errors in laboratory medicine. Clin Chem 2002;48:691–8.
- Plebani M, Astion ML, Barth JH, Chen W, de Oliveira Galoro CA, Escuer MI, Ivanov A, Miller WG, Petinos P, Sciacovelli L, Shcolnik W, Simundic AM, Sumarac Z. Harmonization of quality indicators in laboratory medicine. A preliminary consensus. Clin Chem Lab Med 2014;52: 951–8.
- Goswami B, Singh B, Chawla R, Mallika V. Evaluation of errors in a clinical laboratory: a one-year experience. Clin Chem Lab Med 2010;48:63–6.
- Stark A, Jones BA, Chapman D, Well K, Krajenta R, Meier FA, Zarbo RJ. Clinical laboratory specimen rejection – association with the site of patient care and patients’ characteristics: findings from a single health care organization. Arch Pathol Lab Med 2007;131:588–92.
- Dale JC, Novis DA. Outpatient phlebotomy success and reasons for specimen rejection. Arch Pathol Lab Med 2002;126:416–9.
- Astles JR, Stang H, Alspach T, Mitchell G, Gagnon M, Bosse D. CLIA requirements for proficiency testing: the basics for laboratory professionals. MLO Med Lab Obs 2013;45:8–10, 12, 14–5; quiz 16.
- Llopis MA, Trujillo G, Llovet MI, Tarres E, Ibarz M, Biosca C, Ruiz R, Kirchner MJ, Alvarez V, Busquets G, Domenech MV, Figueres C, Minchinela J, Pastor RM, Perich C, Ricos C, Sansalvador M, Palmada MS. Quality indicators and specifications for key analytical-extranalytical processes in the clinical laboratory. Five years’ experience using the Six Sigma concept. Clin Chem Lab Med 2011; 49:463–70.
- Carraro P, Plebani M. Errors in a stat laboratory: types and frequencies 10 years later. Clin Chem 2007;53:1338–42.
- Nevalainen D, Berte L, Kraft C, Leigh E, Picaso L, Morgan T. Evaluating laboratory performance on quality indicators with the six sigma scale. Arch Pathol Lab Med 2000;124:516–9.