References
- Andersson R., Rizell S. Elektronikutrustning till kroppspletysmograf för registering av and-ningsförlopp. Master thesis, Division of Applied Electronics, Chalmers University of Technology, Göteborg 1968
- Bargeton D., Barrès G. Time characteristics and frequency response of body plethysmograph. Body Plethysmography, A. B. DuBois, K. P. van de Woestijne. Karger, Basel 1969; 2–23
- Bartlett R. G., Jr., Brubach H. F., Trimble R. C., Specht H. Airway resistance measurements during any breathing pattern in man. J. appl. Physiol. 1959; 14: 89
- Bosman A. R., Honour A. J., De Lee G. J., Marshall R., Stott F. D. A method for measuring instantaneous pulmonary capillary bloodflow and right ventricular stroke volume in man. Clin. Sci. 1964; 26: 247
- Clément J., van de Woestijne K. P. Pressure correction in volume and flow-displacement body plethysmography. J. appl. Physiol. 1969; 27: 895
- Du Bois A. B., Botelho S. Y., Bedell G., Marshall R. A rapid plethysmographic method for measuring thoracic gas volume. A comparison with a N2washout method for measuring FRC in normal subjects. J. clin. Invest. 1956; 35: 322
- DuBois A. B., Botelho S. Y., Comroe J. H., Jr. A new method for measuring airway resistance in man using a body plethysmograph: Values in normal subjects and in patients with respiratory disease. J. clin. Invest. 1956; 35: 325
- Finucane K. E., Egan B. A., Dawson S. V. Linearity and frequency response of pneumotachographs. J. appl. Physiol. 1972; 32: 121
- Grimby G., Takishima T., Graham W., Macklem P., Mead J. Frequency dependence of flow resistance in patients with obstructive lung disease. J. clin. Invest. 1968; 47: 1455
- Jaeger M. J., Otis A. B. Measurement of airway resistance with a volume displacement body plethysmograph. J. appl. Physiol. 1964; 19: 813
- Jonson B., Bouhuys A. The measurement of alveolar pressure. J. appl. Physiol. 1967; 22: 1081
- Mc Call C. B., Hyatt R. E., Noble F. W., Fry D. L. Harmonic content of certain respiratory flow phenomena of normal individuals. J. appl. Physiol. 1957; 10: 215
- Mead J. Measurement of inertia of the lungs at increased ambient pressure. J. appl. Physiol. 1956; 9: 208
- Mead J. Volume displacement body plethysmograph for respiratory measurements in human subjects. J. appl. Physiol. 1960; 15: 736
- Reichel G. Differences between intrathoracic gas measured by the body plethysmograph and functional residual capacity determined by gas dilution methods. Body Plethysmography, A. B. DuBois, K. P. van de Woestijne. Karger, Basel 1969; 188–193
- Skoogh B.-E. Normal airways conductance at different lung volumes. Scand. J. clin. Lab. Invest. 1973; 31: 429
- Skoogh B.-E. Normal static lung volumes determined by combined plethysmographic and pneumotachographic technique. Scand. J. clin. Lab. Invest. 1973; 31: 443
- Woestijne K. P., van de Bouhuys A. Spirometer response and pressure correction in body plethysmography. Body Plethysmography, A. B. DuBois, K. P. van de Woestijne. Karger, Basel 1969; 64–74