References
- Lukaski H C, Johnson P E, Bolunchuk W W, Lykken G I. Assessment of fat-free mass using bioelectrical impedance measurements of the human body. Am J Clin Nutr 1985; 41: 810–7
- Lukaski H C, Bolonchuk W W, Hall C B, Siders W A. Validation of tetrapolar bioelectrical impedance method to assess human body composition. J Appl Physiol 1986; 60: 1327–32
- Pethig R. Dialectric and Electronic Properties of Biological Materials. John Wiley and Sons, Chichester 1979; 225–35
- Nyboer J, Bagno S, Nimus L F. The electrical impedance plethysmograph an electrical volume recorder. National Research Council, Committee on Aviation Medicine. 1943, Report No 149
- Hoffer E C, Meador C K, Simpson D C. Correlation of whole-body impedance with total body water volume. J Appl Physiol 1969; 27: 531–4
- Behnke A R, Wilmore J H. Evaluation and Regulation of Body Build and Composition. Prentice Hall, Engle-wood Cliffs, NJ 1974; 38–52
- Durnin J VGA, Womersley J. Body fat assessed from total body density and its estimation from skinfold thickness: measurements on 481 men and women aged from 16–72 years. Br J Nutr 1974; 32: 77–97
- Boddy K, King P C, Tothill P, Strong J A. Measurement of total body potassium with a shadow shield whole-body counter: calibration and errors. Phys Med Biol 1971; 16: 275–82
- Cohn S H, Vaswani A N, Yasumura S, Yuen K, Ellis K J. Assessment of cellular mass and lean body mass by noninvasive nuclear techniques. J Lab Clin Med 1985; 105: 305–11
- Siri W E. Body composition from fluid spaces and density: analysis of methods. Advances in Biological and Medical Physics, J H Lawrence, C A Tobias. Academic Press, New York 1956; 4
- Goodship T HJ. Nutritional Status in Chronic Ambulatory Peritoneal Dialysis. Dissertation, University of Newcastle upon Tyne, Newcastle upon Tyne 1988
- Hawkins T, Goode A W. The determination of total-body potassium using a whole body monitor. Phys Med Biol 1976; 21: 293–7
- Thomasset A. Bio-electrical properties of tissue impedance measurements. Lyon Med 1962; 207: 107–18
- Nyboer J, Liedtke R J, Reid K A, Gessert W A. Nontraumatic electrical detection of total body water and density in man. Med Jadertina 1983; 15((Suppl. 2))381–4
- Cohn S H, Ellis K J, Vartsky D, Sawitsky A, Gartenhaus W, Yasumura S, Vaswani A N. Comparison of methods of estimating body fat in normal subjects and cancer patients. Am J Clin Nutr 1981; 34: 2839–47
- Lukaski H C, Mendez J, Buskirk E R, Cohn S H. Comparison of methods of assessment of body composition including neutron activation analysis of total body nitrogen. Metabolism 1981; 30: 778–83
- Behnke A R, Feen B G, Weldham W C. Specific gravity ofhealthy men. JAMA 1942; 118: 495–502
- Beynen A C, Gundlach B L. Methods for measuring body fat. Medicographia 1985; 7: 39–41
- Behnke A R, Ossermann E F, Welham W C. Lean body mass: its clinical significance and estimation from excess fat and total body water determinations. Arch Int Med 1953; 91: 585–95
- Wang J, Heymsfield S B, Aulet M, Thornton J C, Pierson R N. Body fat from body density: underwater weighing vs. dual-photon absorptiometry. Am J Physiol 1989; 256: E829–E834
- Jensen M D, Braun J S, Vetter R J, Marsh H M. Measurement of body potassium with a whole-body counter: relationship between lead body mass and resting energy expenditure. Mayo Clin Proc 1988; 63: 864–8
- Colt E WD, Wang J, Stallone F, Van Itallie T B, Pierson R N. A possible loss of potasium in obesity. Am J Clin Nutr 1981; 34: 367–72
- Gray D S, Bray G A, Gemayel N, Kaplan K. Effect of obesity on bioelectrical impedance. Am J Clin Nutr 1989; 50: 255–60
- Cohn S H. How valid are bioelectric impedance measurements in body composition studies? Am J Clin Nutr 1985; 42: 889–90