Use of calcium-titrated sodium heparinate for ionized calcium determination on plasma and whole blood (heparinized blood sampler B-129 Radiometer)

, , , &
Pages 303-306 | Received 10 Sep 1990, Accepted 27 Nov 1990, Published online: 08 Jul 2009

References

  • Bourdeau A M. Contribution l'étude du dosage du calcium ionisé dans le sang par un électrode à membrane liquide. Ph. D. (Pharmacy). University René Descartes, Paris 1972
  • Falch-Christiansen T. Heparin and blood sampling lor pH, blood gases and direct potentiometric electrolyte analysis. Radiometer (private press), Copenhagen 1986; vol 1
  • Larsson L, Öhman S. Effect of silicon-separator tubes and storage time on ionized calcium in serum. Clin Chem 1985; 31: 169–70
  • Moore E W. Ionized calcium in normal serum, ultrafiltrates and whole blood determined by ion-exchange electrodes. J Clin Invest 1970; 49: 318–33
  • Sachs C, Bourdeau A M, Balsan S. Détermination du calcium ionisé dans le sérum avec une électrode spécifique à membrane liquide. Ann Biol Clin 1969; 27: 487–509
  • Sachs C, Rabouine P, Kindermans C, Sage G. Preanalytical dilution errors in ionized calcium determination on plasma and whole blood. Methodology and Clinical Applications of Ion-Selective Electrodes, A HJ Maas, B Buckley, H Marsoner, N E Saris, R Sprokholt. Radiometer (private press), Copenhagen 1987; vol 8: 117–23
  • Sachs C, Rabouine P, Chaneac M, Kindermans C, Dechaux M. Anticoagulant-induced preanalytical errors in ionized calcium determination on plasma and whole blood. Scand J Clin Lab Invest 1989; 49: 647–51
  • Toffaletti J, Blosser N, Kirvan K. Effects of storage temperature and time before centrifugation on ionized calcium in blood collected in plain Vacutainer Tubes and silicon separation (SST) tubes. Clin Chem 1984; 30: 553–6
  • Becton-Dickinson. Vacutainer Serum Separator (SST) Tubes. Method instruction. Becton-Dickinson Inc., Rutherford, NJ 1984
  • Urban P, Buchmann B, Scheidegger D. Facilitated determination of ionized calcium. Clin Chem 1985; 31: 264–66
  • Larsson L, Finnström O, Nilsson B, Öhman S. Evaluation of Radiometer ICAI as a routine instrument for serum ionized calcium and its application for whole blood capillary samples from newborn infants. Scand J Clin Lab Invest 1983; 42: 21–6
  • Nelson N, Finnström O, Larsson L. Neonatal reference values for ionized calcium, phosphate and magnesium. Selection of reference population by optimality criteria. Scand J Clin Lab Invest 1987; 47: 111–7

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.