Cardiac Pacemakers and Electrocautery in Ophthalmic Surgery

Pages 408-411 | Received 14 Jan 2012, Accepted 09 Jul 2012, Published online: 12 Oct 2012

REFERENCES

  • Sager DP. Current facts on pacemaker electromagnetic interference and their application to clinical care. Heart Lung 1987;16:211–221.
  • Bayes J. A survey of ophthalmic anesthetists on managing pacemakers and implanted cardiac defibrillators. Anesth Analg 2006 Dec;103(6):1615–1616.
  • Rozner MA. Review of electrical interference in implanted cardiac devices. Pacing Clin Electrophysiol 2003; 26 (4 Pt 1):923–925.
  • Practice Advisory for the perioperative management of patients with cardiac rhythm management devices: pacemakers and implantable cardioverterdefibrillators: A report by the American Society of Anesthesiologists TaskForce on Perioperative Management of Patients with Cardiac Rhythm Management Devices. Anesthesiology 2005; 103:186–198.
  • Eagle KA, Berger PB, Calkins H, Chaitman BR, Ewy GA, Fleischmann KE, Fleisher LA, Froehlich JB, Gusberg RJ, Leppo JA, Ryan T, Schlant RC, Winters WL Jr, Gibbons RJ, Antman EM, Alpert JS, Faxon DP, Fuster V, Gregoratos G, Jacobs AK, Hiratzka LF, Russell RO, Smith SC Jr. ACC/AHA Guideline Update for Perioperative Cardiovascular Evaluation for Noncardiac Surgery--Executive Summary. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines AnesthAnalg 2002 May;94(5):1052–1064.
  • Goldschlager N, Epstein A, Friedman P, Gang E, Krol R, Olshansky B. Environmental and drug effects on patients with pacemakers and implantable cardioverter/defibrillators: a practical guide to patient treatment. Arch Intern Med 2001 Mar 12;161(5):649–655.
  • Pinski SL, Trohman RG. Interference in implanted cardiac devices, part I. Pacing ClinElectrophysiol 2002; 25:1367–1381.
  • Pinski SL, Trohman RG. Interference in implanted cardiac devices, part II. Pacing ClinElectrophysiol 2002; 25:1496–1509.
  • Medicines and Healthcare Products Regulatory Agency (MHRA). Guidelines for the perioperative management of patients with implantable pacemakers or implantable cardioverter defibrillators, where the use of surgical diathermy/electrocautery is anticipated. March 2006;1–5.
  • Preisman S, Cheng DC. Life-threatening ventricular dysrhythmias with inadvertent asynchronous temporary pacing after cardiac surgery. Anesthesiology 1999; 91:880–883.
  • Trankina MF, Black S, Gibby G. Pacemakers: Perioperative evaluation, management and complications. Anesthesiology 2000; 93:A1193.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.