33
Views
7
CrossRef citations to date
0
Altmetric
Original Article

Scanning Electron Microscopy in the Backscattered Electron Imaging (BEI) Mode: Applications to Clinical Hematology

Pages 711-721 | Published online: 10 Jul 2009

References

  • Wells O C. Backscattered electron image (BEI) in the scanning electron microscope (SEM). Scanning Electron Microsc 1977; 1: 747–771
  • Peters K R. Validation of George and Robinson SE-I signal theorem–Implications for ultrahigh resolution SEM on bulk untitled specimens. Proc. 40th Annual Meeting of the Electronic Microscopy Society of America. Cloitor's Pub., 1982; 368–369
  • Pawley J. Low voltage scanning electron microscopy. Journal of Microscopy 1984; 136: 45–68
  • Gomori G. Microscopic Histochemistry– Principles and Practice. University of Chicago Press, Chicago 1952; 273
  • Graham R C, Karnovsky M J. The early stages of absorption of injected horseradish peroxidase in the proximate tubules of mouse kidney: Ultrastructural cytochemistry by a new technique. J Histochem Cytochem 1966; 13: 520
  • Abraham J L, DeNee P B. Scanning electron microscope histochemistry using backscattered electrons and metal stains. Lancet 1973; 1: 1125
  • Albrecht R M, Jordan C, Hong R. Identification of monocytes, granulocytes and lymphocytes: Correlation of histological, histochemical and functional properties with surface structure as viewed by scanning electron microscopy. Scanning Electron Microsc 1978; II: 511–524
  • Becker R P, De Bruyn P PH. Backscattered electron imaging of endogenous peroxidase activity in rat bone marrow. Scanning Electron Microsc 1976; ll: 172–178
  • Becker R P, Sogard M. Visualization of subsurface structures in cells and tissue by backscattered electron imaging. Scanning Electron Microsc 1979; II: 835–870
  • Soligo D, de Harven E. Ultrastructural cyto-chemical localizations by backscattered electron imaging of white blood cells. J Histochem Cytochem 1981; 29: 1071–1079
  • de Harven E, Soligo D, Lampen N. Scanning electron microscopy of human leukocytes. Scanning Electron Microsc 1984; II: 773–782
  • Soligo D, Lampen N, de Harven E. Backscattered electron imaging of human leukocytes. Scanning Electron Microsc 1981; II: 95–103
  • Soligo D, Lambertenghi-Deliliers G, de Harven E. Scanning electron microscope cytochemistry of normal and leukaemic leukocytes. Biol Cell 1983; 48: 39–46
  • Soligo D, de Harven E. Iron carbonyl, a tracer for phagocytosis in scanning electron microscopy. J Reticuloendothel Soc 1982; 32: 201–207
  • Molday R S, Maher P. A review of cell surface makers and labelling techniques of scanning electron microscopy. J Histochem 1980; 12: 273–315
  • Hammerling U, Polliack A, Lampen N, Sabety M, de Harven E. Scanning electron microscopy of tobacco mosaic virus-labeled lymphocyte surface antigen. J Exp Med 1975; 141: 518–523
  • Weller N K. Visualization of Con A binding sites with scanning electron microscopy. J Cell Biol 1974; 63: 699–707
  • Kumon H, Uno F, Taward J. A morphologically recognizable marker for scanning immunoelectron microscopy. 1. T4-bacterio-phase. Virology 1976; 70: 554–557
  • de Harven E, Pla D, Lampen N. Labeling of lymphocyte surface immunoglobulins with T4 as marker for scanning electron microscopy. Scanning Electron Microsc 1979; II: 611–618
  • Horisberger M. Evaluation of colloidal gold as a cytochemical marker for transmission and scanning electron microscopy. Biol Cell 1979; 36: 253–258
  • De Mey J. Colloidal gold probes in immunocytochemistry. Immunocytochemistry: Practical Application in Pathology and Biology, J M Polak, S Van Noorden. John Wright PSG Inc., Boston 1983; 82–112
  • de Harven E, Leung R, Christensen H. A novel approach for scanning electron microscopy of colloidal gold-labeled cell surfaces. J Cell Biol 1984; 99: 53–57
  • de Harven E, Soligo D. Scanning electron microscopy of cell surface antigens labeled with colloidal gold. Amer J Anat 1986; 175: 277–287
  • Horisberger M, Tacchini-Vollanthen M. Stability and steric hindrance of lectin-labeled gold markers in transmission and scanning electron microscopy. Lectins 1983; lll: 189–198
  • Soligo D, de Harven E, Nava M T, Lambertenghi-Deliliers G. Immunocytochemistry with backscattered electrons. Science of Specimen Preparation for Microscopy and Microanalysis, M Muller, R P Becker, A Boyde, J J Wolosewick. SEM Inc., Chicago 1986; 289–297
  • Walther P, Muller M. Detection of small (5–15 nm) gold-labeled surface antigens using back-scattered electrons. Science of Biological Specimen Preparation for Microscopy and Microanalysis, M Muller, R P Becker, A Boyde, J J Wolosewick. SEM Inc., Chicago 1986; 195–201
  • Slot J W, Geuze H J. A new method of preparing gold probes for multiple-labeling cytochemistry. Eur J Cell Biol 1984; 38(1)87–93
  • Roth J, Bendayan M, Orci L. Ultrastructural localization of intracellular antigens by the use of protein A-gold complex. J Histochem Cytochem 1978; 26: 1074–1081
  • Bendayan M. Protein A-gold electron microscopic immunocytochemistry: Methods, applications and limitations. J Electron Microscopy Technique 1984; 1: 243–270
  • Soligo D, Lambertenghi-Deliliers G, de Harven E. Immuno-scanning electron microscopy of normal and leukemic blood cells labeled with colloidal gold. Scanning Microsc 1987; 1: 719–726
  • Lin P S, Wallach D FH, Tsai S. Temperature-induced variations in the surface topology of cultured lymphocytes are revealed by scanning electron microscopy. Proc Nat Acad Sci 1973; 70(9)2492–2496
  • Loor F, Hagg L B. The modulation of microprojections on the lymphocyte membrane and the redistribution of membrane-bound ligands–A correlation. Eur J Immunol 1975; 5: 854–865
  • Peters K R. Conditions required for high quality high magnification images in secondary electron-I scanning electron microscopy. Scanning Electron Microsc 1982; IV: 1359–1372
  • Boyde A, Bailey E, Jones S J, Tamarin A. Dimensional changes during specimen preparation for scanning electron microscopy. Scanning Electron Microsc 1977; I: 507–518
  • Piche Y, Peterson R L, Ackerley C A, Rauser W E. RNase-gold labeling in primary roots of Zea Mays L: Evaluation of a particulate marker. Plant Science Letters 1984; 36: 155–160
  • de Harven E, Soligo D. Should we be counting immunogold marker particles on cell surfaces with the SEM?. J Microscopy 1987; 146: 183–189
  • de Harven E, Soligo D, Christensen H, Bhupal V. Comparative surface morphology of human B- and T-derived peripheral lymphocytes. Abstracts of Sixth International Congress of Immunology. Natl. Res. Council Canada, Toronto 1986; 239
  • de Harven E, Soligo D. Immunogold labeling of human leukocytes for SEM: Quantitative aspects of methodology. Scanning Microsc 1987; 1: 713–718
  • Polliack A, Braylan R, Golomb H. Scanning electron microscopy of hairy cells in hairy-cell leukaemia. Lancet 1974; 2: 1013–1014

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.