References
- Marmor JB, Hahn GM. Ultrasound heating in previously irradiated sites. Int J Radiat Oncol Biol Phys 1978; 4: 1029–1032
- Corry PM, Barlogie B, Tilchen EJ, Armour EPR. Ultrasound-induced hyperthermia for the treatment of human superficial tumors. Int J Radiat Oncol Biol Phys 1982; 8: 1225–1229
- Fessenden P, Lee ER, Anderson TL, Strohbehn JW, Meyer JL, Samulski TV, Marmor JB. Experience with a multitransducer ultrasound system for localized hyperthermia of deep tissues. IEEE Trans Biomed Eng 1984; 31: 126–135
- Lele PP. Physical aspects and clinical studies with ultrasound hyperthermia. Hyperthermia in Cancer Therapy, FC Storm. Hall Medical Publishers, Boston 1983; 333–367
- Hynynen K, Watmough DJ, Shammari M, Wilmot G, Murthy MSN, Mallard JR, Fuller M, Sarkar T. A clinical hyperthermia unit utilizing an array of seven focused ultrasonic transducers. Proceedings of the IEEE Ultrasonics Symposium 1983a; 816–821
- Shapiro E, Seppi E, Zitelli L, Henderson S, Wehlau A, Wu G, Dittmer C. A large aperture ultrasonic array system for hyperthermia treatment of deep-seated tumors. Proceedings of the IEEE Ultrasonics Symposium 1985; 942–948
- Ocheltree KB, Benkeser PJ, Frizzell LA, Cain CA. An ultrasonic phased array applicator for hypothermia. IEEE Trans. Sonics and Ultras. 1984; 31: 526–531
- Benkeser PJ, Ocheltree KB, Frizzell LA, Cain CA. Ultrasound phased array hyperthermia applicator. Proceedings of the 7th Annual Conference of IEEE Engineering in Medicine and Biology Society. 1985; 337–340
- Cain CA, Umemura S. Annular and sector phased array applicators for ultrasound hyperthermia. Proceedings of the IEEE Ultrasonics Symposium 1985; 936–941
- Stewart HF. Ultrasonic measurement techniques and equipment output levels. Essentials of Medical Ultrasound, MH Repacholi, DA Benwell. Humana Press, Clifton, NJ 1982; 77–116
- Martin CJ, Law ANR. Design of thermistor probes for measurement of ultrasound intensity distributions. Ultrasonics 1983; 21: 85–90
- Fry WJ, Fry RB. Determination of absolute sound levels and acoustic absorption coefficients by thermocouple probes-experiment. J Acoustical Soc Am 1954; 26: 311–317
- Cristensen DA, Kuhn PK. Temperature errors caused by probe heating in ultrasound hyperthermia. Proceedings of the 33rd Annual Meeting of the Radiation Research Society. 1985; 61
- Cetas TC, Connor WG. Thermometry considerations in localized hyperthermia. Med Phys 1978; 5: 79–91
- Hynynen K, Martin CJ, Watmough DJ, Mallard JR. Errors in temperature measurement by thermocouple probes during ultrasound induced hyperthermia. Br J Radiol 1983b; 56: 969–970
- Cetas TC. Use of dog kidneys as in vivo thermal models. 7th Annual Conference of IEEE Engineering in Medicine and Biology Society. September, 1985
- Hynynen K, Roemer RB, Moros E, Johnson C, Anhalt D. The effect of scanning speed on temperature and equivalent thermal exposure distributions during ultrasound hyperthermia in vivo. IEEE Trans Microwave Theory Tech 1986; 34: 552–559