References
- Rossi S, Di Stasi M, Buscarini E, Quaretti P, Garbagnati F, Squassante L, et al. Percutaneous RF interstitial thermal ablation in the treatment of hepatic cancer. Am J Roentgenol 1996;167:759–68
- McGahan JP, Dodd GD. Radiofrequency ablation of the liver current status. Am J Roentgenol 2001;176:3–16
- Sapin-de Brosses E, Gennisson JL, Pernot M, Fink M, Tanter M. Temperature dependence of the shear modulus of soft tissues assessed by ultrasound. Phys Med Biol 2010;55:1701–18
- Rhim H, Dodd GD. Radiofrequency thermal ablation of liver tumors. J Clin Ultrasound 1999;27:221–9
- Moffitt TP, Baker DA, Kirkpatrick SJ, Prahl SA. Mechanical properties of repaired liver using an argon beam coagulator with albumin. Proc SPIE 2002;4609:178–85
- Mahvi DM. Hepatic Cryoablation: US monitoring of extent of necrosis in normal pig liver. Radiology 1998;207:73–7
- Seifert JK, Achenbach T, Heintz A, Böttger TC, Junginger T. Cryotherapy for liver metastases. Int J Colorectal Dis 2000;15:161–6
- Shafir M, Shapiro R, Sung M, Warner R, Sicular A, Klipfei A. Cryoablation of unresectable malignant liver tumors. Am J Surg 1996;171:27–31
- Schön MR, Kollmar O, Wolf S, Schrem H, Matthes M, Akkoc N, et al. Liver transplantation after organ preservation with normothermic extracorporeal perfusion. Ann Surg 2001;233:114–23
- van Gulik TM. New concepts in liver preservation: How the pendulum sways back. Liver Transpl 2009;15:1–3
- Wahlberg JA, Southard JH, Belzer FO. Development of a cold storage solution for pancreas preservation. Cryobiology 1986;23:477–82
- Vogel T, Brockmann JG, Coussios C, Friend PJ. The role of normothermic extracorporeal perfusion in minimizing ischemia reperfusion injury. Transplantation Reviews 2012;26:156–62
- Wex C, Stoll A, Fröhlich M, Arndt S, Lippert H. Comprehensive study of viscoelastic properties of porcine liver tissue using shear rheology. Biorheology 2013;50:115–31
- Bharat S, Techavipoo U, Kiss MZ, Liu W, Varghese T. Monitoring stiffness changes in lesions after radiofrequency ablation at different temperatures and durations of ablation. Ultrasound Med Biol 2005;31:415–22
- Shahmirzadi D, Hou Y, Konofagou EE. Viscoelastic mechanical properties of the canine liver before and after focused ultrasound-induced thermal ablation in vitro. Proceedings of Biomedical Engineering Society Annual Meeting, Atlanta, GA, USA, 2012
- Fahey BJ, Hsu SJ, Wolf PD, Nelson RC, Trahey GE. Liver ablation guidance with acoustic radiation force impulse imaging: challenges and opportunities. Phy Med Biol 2006;51:3785–808
- Mazza E, Nava A, Hahnloser D, Jochum W, Bajka M. The mechanical response of human liver and its relation to histology: An in vivo study. Med Image Anal 2007;11:663–72
- Yeh WC, Li PC, Jeng YM, Hsu HC, Kuo PL, Li ML, et al. Elastic modulus measurements of human liver and correlation with pathology. Ultrasound Med Biol 2002;28:467–74
- Nguyen NH, Du’o’ng MT, Tran TN, Pham P, Grottke O, Tolba R, et al. Influence of a freeze–thaw cycle on the stress–stretch curves of tissues of porcine abdominal organs. J Biomech 2012;45:2382–6
- Geerligs M, Peters GWM, Ackermans PAJ, Oomens CWJ, Baaijens FPT. Linear viscoelastic behavior of subcutaneous adipose tissue. Biorheology 2008;45:677–88
- Peters GWM, Meulman JH, Sauren AAHJ. The applicability of the time/temperature superposition principle to brain tissue. Biorheology 1997;34:127–38
- Chan RW. Estimation of viscoelastic shear properties of vocal-fold tissues based on time-temperature superposition. J Acoust Soc Am 2001;110:1548–61
- Bischof JC, He X. Thermal stability of proteins. Ann NY Acad Sci 2005;1066:12–33
- Samali A, Holmberg CI, Sistonen L, Orrenius S. Thermotolerance and cell death are distinct cellular responses to stress: Dependence on heat shock proteins. FEBS letters 1999;461:306–10
- Halangk W, Stürzebecher J, Matthias R, Schulz HU, Lippert H. Trypsinogen activation in rat pancreatic acinar cells hyperstimulated by caerulein. Biochim Biophys Acta 1997;1362:243–51
- Kiss MZ, Daniels MJ, Varghese T. Investigation of temperature-dependent viscoelastic properties of thermal lesions in ex vivo animal liver tissue. J Biomech 2009;42:959–66
- Hrapko M, van Dommelen JAW, Peters GWM, Wismans JSHM. The influence of test conditions on characterization of the mechanical properties of brain tissue. J Biomech Eng 2008;130:0310031–310
- Liu Z, Bilston L. On the viscoelastic character of liver tissue: Experiments and modelling of the linear behaviour. Biorheology 2000;37:191–201
- Phan-Thien N, Nasseri, S, Bilston LE. Oscillatory squeezing flow of a biological material. Rheologica Acta 2000;39:409–17
- Brown JD. In-vivo and postmortem biomechanics of abdominal organs under compressive loads: Experimental approach in a laparoscopic surgery setup. Ph.D. Thesis, Department of Bioengineering, Seattle, University of Washington, 2003
- Chatelin S, Oudry J, Périchon N, Sandrin L, Allemann P, Soler L, et al. In vivo liver tissue mechanical properties by transient elastography: Comparison with dynamic mechanical analysis. Biorheology 2011;48:75–88
- Kerdok AE. Characterizing the nonlinear mechanical response of liver to surgical manipulation. Ph.D. Thesis, Harvard University, 2006
- Mezger T. The Rheology Handbook: For users of rotational and oscillation rheometers. Hannover: Vincentz Network GmbH & Co KG, 2002
- Schäffler A, Menche N. Biologie Anatomie Physiologie. München: Urban & Fischer, 2000
- Brunon A, Bruyère-Garnier K, Coret M. Mechanical characterization of liver capsule through uniaxial quasi-static tensile tests until failure. J Biomech 2010;43:2221–7
- Snedeker J, Niederer P, Schmidlin F, Farshad M, Demetropoulos C, Lee J, et al. Strain-rate dependent material properties of the porcine and human kidney capsule. J Biomech 2005;38:1011–21
- Plog S, Mundhenk L, Bothe MK, Klymiuk N, Gruber AD. Tissue and cellular expression patterns of porcine CFTR: Similarities to and differences from human CFTR. J Histochem Cytochem 2010;58:785–97
- Ibrahim Z, Busch J, Awwad M, Wagner R, Wells K, Cooper DKC. Selected physiologic compatibilities and incompatibilities between human and porcine organ systems. Xenotransplantation 2006;13:488–99
- Horslen SP, Hammel JM, Fristoe LW, Kangas JA, Collier DS, Sudan DL, et al. Extracorporeal liver perfusion using human and pig livers for acute liver failure. Transplantation 2000;70:1472–8
- Ottensmeyer M, Kerdok A, Howe R, Dawson S. The effects of testing environment on the viscoelastic properties of soft tissues. Proc Med Simul 2004;3078:9–18
- Rosen J, Brown JD, De S, Sinanan M, Hannaford B. Biomechanical properties of abdominal organs in vivo and postmortem under compression loads. J Biomech Eng 2008;130:021020–(1–17)
- Hines-Peralta AU, Pirani N, Clegg P, Cronin N, Ryan TP, Liu Z, et al. Microwave ablation: Results with a 2.45-GHz applicator in ex vivo bovine and in vivo porcine liver. Radiology 2006;239:94–102
- Loganathan S, Radovits T, Hirschberg K, Korkmaz S, Koch A, Karck M, et al. Effects of Custodiol-N, a novel organ preservation solution, on ischemia/reperfusion injury. J Thorac Cardiovasc Surg 2010;139:1048–56
- Klatt D, Friedrich C, Korth Y, Vogt R, Braun J, Sack I. Viscoelastic properties of liver measured by oscillatory rheometry and multifrequency magnetic resonance elastography. Biorheology 2010;47:133–41
- Seki S, Iwamoto H. Disruptive forces for swine heart, liver, and spleen: Their breaking stresses. J Trauma 1998;45:1079–83
- Posnansky O, Guo J, Hirsch S, Papazoglou S, Braun J, Sack I. Fractal network dimension and viscoelastic powerlaw behavior: I. A modeling approach based on a coarse-graining procedure combined with shear oscillatory rheometry. Phys Med Biol 2012;57:4023–40
- Carter FJ, Frank TG, Davies PJ, McLean D, Cuschieri A. Measurements and modelling of the compliance of human and porcine organs. Med Image Anal 2001;5:231–6
- Santago AC, Kemper AR, McNally C, Sparks JL, Duma SM. Freezing affects the mechanical properties of bovine liver. Biomed Sci Instrum 2009a;45:24–9
- Lu YC, Untaroiu CD. Effect of storage methods on indentation-based material properties of abdominal organs. Proc Inst Mech Eng H J Eng Med 2013;227:293–301
- Tamura A, Omori K, Miki K, Lee JB, Yang KH, King AI. Mechanical characterization of porcine abdominal organs. Stapp Car Crash J 2002;46:55–69
- Lovelock JE. The denaturation of lipid-protein complexes as a cause of damage by freezing. Proc R Soc Lond B Biol Sci 1957;147:427–33
- Santago A, Kemper A, McNally C, Sparks J, Duma S. The effect of temperature on the mechanical properties of bovine liver. Biomed Sci Instrum 2009;45:376–81
- Arrhenius S. On the reaction rate of the inversion of non-refined sugar upon souring. Z Phy Chem 1889;4:226–48
- Zoldak G, Zubrik A, Musatov A, Stupak M, Sedlak E. Irreversible thermal denaturation of glucose oxidase from Aspergillus niger is the transition to the denatured state with residual structure. J Biol Chem 2004;279:47601–9
- Chui C, Kobayashi E, Chen X, Hisada T, Sakuma I. Transversely isotropic properties of porcine liver tissue: Experiments and constitutive modeling. Med Biol Eng Comput 2007;45:99–106
- Choi AP, Zheng YP. Estimation of Young's modulus and Poisson's ratio of soft tissue from indentation using two different-sized indentors: Finite element analysis of the finite deformation effect. Med Biol Eng Comput 2005;43:258–64
- Sapareto SA, Dewey WC. Thermal dose determination in cancer therapy. Int J Radiat Oncol Biol Phys 1984;10:787–800
- Dewey WC. Arrhenius relationships from the molecule and cell to the clinic. Int J Hyperthermia 2009;25:3–20
- USDA National Nutrient Database for Standard ReferenceRelease 26. Agricultural Research Service, United States Department of Agriculture. Retrieved from http://www.ars.usda.gov/Services/services.htm 25 Mar. 2014
- Lepock JR, Frey HE, Ritchie KP. Protein denaturation in intact hepatocytes and isolated cellular organelles during heat shock. J Cell Biol 1993;122:1267–76
- Roti Roti JL. Cellular responses to hyperthermia (40–46 °C): Cell killing and molecular events. Int J Hyperthermia 2008;24:3–15
- Chen S, Urban M, Pislaru C, Kinnick R, Zheng Y, Yao A, et al. Shearwave dispersion ultrasound vibrometry (SDUV) for measuring tissue elasticity and viscosity. Ultrason Ferroelectr Freq Control I 2009;56:55–62
- Al-Hadithi TSR, Barnes HA, Walters K. The relationship between the linear (oscillatory) and nonlinear (steady-state) flow properties of a series of polymer and colloidal systems. Colloid Polym Sci 1992;270:40–6
- Wright NT, Humphrey JD. Denaturation of collagen via heating: An irreversible rate process. Annu Rev Biomed Eng 2002;4:109–28
- Miles CA, Bailey AJ. Thermal denaturation of collagen revisited. Proc Indian Acad Sci 1999;111:71–80
- Bitar AC, Santos LAU, Croci AT, Pereira JARM, Bisneto ENF, Giovani AMM, et al. Histological study of fresh versus frozen semitendinous muscle tendon allografts. Clinics (Sao Paulo) 2010;65:297–303
- Reid HC, Harrison DL. Effects of dry and moist heat on selected histological characteristics of beef semimembranosus muscle. J Food Sci 1971;36:206–8