Real-time 2D/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy

, , , &
Pages 1464-1471 | Received 03 May 2013, Accepted 09 Jun 2013, Published online: 23 Jul 2013

References

  • van Herk M. Errors and margins in radiotherapy. Semin Radiat Oncol 2004;14:52–64.
  • Schweikard A, Glosser G, Bodduluri M, Murphy MJ, Adler JR. Robotic motion compensation for respiratory movement during radiosurgery. Comput Aided Surg 2000; 5:263–77.
  • Shah AP, Kupelian PA, Willoughby TR, Langen KM, Meeks SL. An evaluation of intrafraction motion of the prostate in the prone and supine positions using electromagnetic tracking. Radiother Oncol 2011;99:37–43.
  • Cho B, Poulsen PR, Sawant A, Ruan D, Keall PJ. Real-time target position estimation using stereoscopic kilovoltage/megavoltage imaging and external respiratory monitoring for dynamic multileaf collimator tracking. Int J Radiat Oncol Biol Phys 2010;79:269–78.
  • Hughes S, McClelland J, Tarte S, Lawrence D, Ahmad S, Hawkes D, et al. Assessment of two novel ventilatory surrogates for use in the delivery of gated/tracked radiotherapy for non-small cell lung cancer. Radiother Oncol 2009; 91:336–41.
  • Bibault J-E, Prevost B, Dansin E, Mirabel X, Lacornerie T, Lartigau E. Image-guided robotic stereotactic radiation therapy with fiducial-free tumor tracking for lung cancer. Radiat Oncol 2012;7:102.
  • Yang Y, Zhong Z, Guo X, Wang J, Anderson J, Solberg T, et al. A novel markerless technique to evaluate daily lung tumor motion based on conventional cone-beam CT projection data. Int J Radiat Oncol 2012;82:e749–56.
  • Lewis J, Li R, Watkins W, Lawson J, Segars W, Cervĩo L, et al. Markerless lung tumor tracking and trajectory reconstruction using rotational cone-beam projections: A feasibility study. Phys Med Biol 2010;55:2505–22.
  • Gendrin C, Markelj P, Pawiro SA, Spoerk J, Bloch C, Weber C, et al. Validation for 2D/3D registration II: The comparison of intensity and gradient based merit functions using a new gold standard data set. Med Phys 2011;38:1491–502.
  • Suh Y, Dietrich S, Keall PJ. Geometric uncertainty of 2D projection imaging in monitoring 3D tumor motion. Phys Med Biol 2007;52:3439–54.
  • Gendrin C, Furtado H, Weber C, Bloch C, Figl M, Pawiro S, et al. Monitoring tumor motion by real time 2D/3D registration during radiotherapy. Radiother Oncol 2012;102:274–80.
  • Markelj P, Tomaževič D, Likar B, Pernuš F. A review of 3D/2D registration methods for image-guided interventions. Med Image Anal 2012;16:642–61.
  • Udrescu C, Mornex F, Tanguy R, Chapet O. ExacTrac snap verification: A new tool for ensuring quality control for lung stereotactic body radiation therapy. Int J Radiat Oncol 2013; 85:e89–94.
  • Spoerk J, Gendrin C, Weber C, Figl M, Pawiro S, Furtado H, et al. High-performance GPU-based rendering for real-time, rigid 2D/3D-image registration and motion prediction in radiation oncology. Z Med Phys 2012;22:13–20.
  • Furtado H, Gendrin C, Bloch C, Spoerk J, Pawiro S, Weber C, et al. Real-time 2D/3D registration for tumor motion tracking during radiotherapy. In: Progress in biomedical optics and imaging. Proc SPIE 8314, Medical Imaging 2012.
  • Maes F, Collignon A, Vandermeulen D, Marchal G, Suetens P. Multimodality image registration by maximization of mutual information. IEEE Trans Med Imag 1997;2: 187–98.
  • Pawiro SA, Markelj P, Pernuš F, Gendrin C, Figl M, Weber C, et al. Validation for 2D/3D registration. I: A new gold standard data set. Med Phys 2011;38:1481–90.
  • Powell M. The NEWUOA software for unconstrained optimization without derivatives. In: Pillo GD, Roma M, editors. Nonconvex optimization and its applications. New York: Springer; pp. 255–297.
  • Hoisak J, Sixel K, Tirona R, Cheung P, Pignol J-P. Correlation of lung tumor motion with external surrogate indicators of respiration. Int J Radiat Oncol 2004;60: 1298–306.
  • Blessing M, Arns A, Stsepankou D, Wertz H, Lohr F, Hesser J, et al. OC-0060 Workflow automation for ultrafast kilovoltage-megavoltage cone-beam CT for image guided radiotherapy (abstract). Radiother Oncol 2013;106:S22.
  • Steiner E, Kostresevic B, Stock M, Baroni G, Georg D. OC-0062 Imaging dose assessment for intrafraction motion management in ion beam therapy (abstract). Radiother Oncol 2013;106:S23.
  • Zimmerman J, Korreman S, Persson G, Cattell H, Svatos M, Sawant A, et al. DMLC motion tracking of moving targets for intensity modulated arc therapy treatment – A feasibility study. Acta Oncol 2009;48:245–50.
  • Fledelius W, Keall PJ, Cho B, Yang X, Morf D, Scheib S, et al. Tracking latency in image-based dynamic MLC tracking with direct image access. Acta Oncol 2011; 50:952–9.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.