974
Views
16
CrossRef citations to date
0
Altmetric
Clinical Study

Point-of-Care Measurement of Serum Creatinine in the Intensive Care Unit

, , , &
Pages 13-18 | Received 01 May 2011, Accepted 04 Sep 2011, Published online: 20 Oct 2011

REFERENCES

  • Kost GJ. Knowledge optimization theory and application to point-of-care testing. Stud Health Technol Inform. 1999;62:189–190.
  • Tsai WW, Nash DB, Seamonds B, Weir GJ. Point-of-care versus central laboratory testing: An economic analysis in an academic medical center. Clin Ther. 1994;16:898–910, discussion 854.
  • Kost GJ. Guidelines for point-of-care testing. Improving patient outcomes. Am J Clin Pathol. 1995;104(Suppl. 1):S111–S127.
  • Price CP. Medical and economic outcomes of point-of-care testing. Clin Chem Lab Med. 2002;40:246–251.
  • Scalise D. Poised for growth. Point-of-care testing. Hosp Health Netw. 2006;80:77–83.
  • Bellomo R, Ronco C, Kellum JA, Mehta RL, Palevsky P. Acute renal failure—Definition, outcome measures, animal models, fluid therapy and information technology needs: The Second International Consensus Conference of the Acute Dialysis Quality Initiative (ADQI) Group. Crit Care. 2004;8:R204–R212, doi: 10.1186/cc2872.
  • Mehta RLKJ, Shah SV, Molitoris BA, Ronco C, Warnock DG. LAatAKIN. Acute kidney injury network: Report of an initiative to improve outcomes in acute kidney injury. Crit Care. 2007;11:R31.
  • Zavada J, Hoste E, Cartin-Ceba R, . A comparison of three methods to estimate baseline creatinine for RIFLE classification. Nephrol Dial Transplant. 2010;25:3911–3918.
  • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–310.
  • Bellomo R, Kellum JA, Ronco C. Defining acute renal failure: Physiological principles. Intensive Care Med. 2004;30:33–37.
  • Miller WG, Myers GL, Ashwood ER, . Creatinine measurement: State of the art in accuracy and interlaboratory harmonization. Arch Pathol Lab Med. 2005;129:297–304.
  • Blijenberg BG, Brouwer HJ. The accuracy of creatinine methods based on the Jaffe reaction: A questionable matter. Eur J Clin Chem Clin Biochem. 1994;32:909–913.
  • Gerard SK, Khayam-Bashi H. Characterization of creatinine error in ketotic patients. A prospective comparison of alkaline picrate methods with an enzymatic method. Am J Clin Pathol. 1985;84:659–664.
  • Daugherty NA, Hammond KB, Osberg IM. Bilirubin interference with the kinetic Jaffe method for serum creatinine. Clin Chem. 1978;24:392–393.
  • Srisawasdi P, Chaichanajarernkul U, Teerakanjana N, Vanavanan S, Kroll MH. Exogenous interferences with Jaffe creatinine assays: Addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods. J Clin Lab Anal. 2010;24:123–133.
  • Franzini C, Morelli AM, Cattozzo G. Use of a synthetic soluble bilirubin derivative to assess interference in creatinine measurements. Clin Chem. 1991;37:236–238.
  • Cobbaert CM, Baadenhuijsen H, Weykamp CW. Prime time for enzymatic creatinine methods in pediatrics. Clin Chem. 2009;55:549–558.
  • Da Rin G, Amici G, Virga G, Bardin C, Calzavara P, Bocci C. Correction of glucose concentration interference on Jaffe kinetic creatinine assay in peritoneal dialysis. Am J Nephrol. 1995;15:480–487.
  • Larpent L, Verger C. The need for using an enzymatic colorimetric assay in creatinine determination of peritoneal dialysis solutions. Perit Dial Int. 1990;10:89–92.
  • Lo SC, Tsai KS. Glucose interference in Jaffe creatinine method: Effect of calcium from peritoneal dialysate. Clin Chem. 1994;40:2326–2327.
  • Swain RR, Briggs SL. Positive interference with the Jaffe reaction by cephalosporin antibiotics. Clin Chem. 1977;23:1340–1342.
  • Cook JG. Factors influencing the assay of creatinine. Ann Clin Biochem. 1975;12:219–232.
  • Haeckel R. Assay of creatinine in serum, with use of fuller’s earth to remove interferents. Clin Chem. 1981;27:179–183.
  • Schoenmakers CH, Kuller T, Lindemans J, Blijenberg BG. Automated enzymatic methods for creatinine measurement with special attention to bilirubin interference. Eur J Clin Chem Clin Biochem. 1993;31:861–868.
  • Guder WG, Hoffmann GE, Hubbuch A, Poppe WA, Siedel J, Price CP. Multicentre evaluation of an enzymatic method for creatinine determination using a sensitive colour reagent. J Clin Chem Clin Biochem. 1986;24:889–902.
  • O‘Leary N, Pembroke A, Duggan PF. A simplified procedure for eliminating the negative interference of bilirubin in the Jaffe reaction for creatinine. Clin Chem. 1992;38:1749–1751.
  • Myers GL, Miller WG, Coresh J, . Recommendations for improving serum creatinine measurement: A report from the Laboratory Working Group of the National Kidney Disease Education Program. Clin Chem. 2006;52:5–18.
  • Udy A, O‘Donoghue S, D‘Intini V, Healy H, Lipman J. Point of care measurement of plasma creatinine in critically ill patients with acute kidney injury. Anaesthesia. 2009;64:403–407.
  • Amici G, Da Rin G, Bardin C, Gatti PL, Calconi G, Bocci C. Calcium lactate interference in measuring creatinine in peritoneal dialysis fluids by the Jaffe kinetic method. Adv Perit Dial. 1996;12:257–260.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.