246
Views
34
CrossRef citations to date
0
Altmetric
Research Article

Physically-based biodosimetry using in vivo EPR of teeth in patients undergoing total body irradiation

, , , , , , , , & show all
Pages 766-775 | Received 05 Nov 2010, Accepted 14 Apr 2011, Published online: 23 Jun 2011

References

  • Alexander GA, Swartz HM, Amundson SA, Blakely WF, Buddemeier B, Gallez B, et al. 2007. Acute dosimetry consensus committee recommendations on biodosimetry applications in events involving uses of radiation by terrorists and radiation accidents. Radiation Measurements 42:972–996.
  • Amundson SA, Grace MB, McLeland CB, Epperly MW, Yeager A, Zhan Q, Greenberger JS, Fornace AJ. 2004. Human in vivo radiation-induced biomarkers: Gene expression changes in radiotherapy patients. Cancer Research 64:6368–6371.
  • Amundson SA, Lee RA, Koch-Paiz CA, Bittner ML, Meltzer P, Trent JM, Fornace AJ. 2003. Differential responses of stress genes to low dose-rate gamma irradiation. Molecular Cancer Research 1:445–452.
  • Blakely WF, Carr Z, Chu MCM, Dayal-Drager R, Fujimoto K, Hopmeir M, Kulka U, Lillis-Hearne P, Livingston GK, Lloyd DC. 2009. WHO 1st consultation on the development of a global biodosimetry laboratories network for radiation emergencies (BioDoseNet). Radiation Research 171:127–139.
  • Brengues M, Paap B, Bittner M, Amundson SA, Seligmann B, Korn R, Lenigk R, Zenhausern F. 2010. Biodosimetry on small blood volume using gene expression assay. Health Physics 98:179–185.
  • Britten R, Mitchell S, Johnson AM, Singletary SJ, Keeney SK, Nyalwidhe JO, Karbassi I, Lonart G, Sanford LD, Drake RR. 2010. The identification of serum biomarkers of high-LET radiation exposure and biological sequelae. Health Physics 98:196–203.
  • Chen Y, Ying T, Nowak I, Wang N, Hyrien O, Wilkins R, Ferrarotto C, Sun H, Dertinger SD. 2010. Validating high throughput micronucleus analysis of peripheral reticulocytes for radiation biodosimetry: Benchmark against dicentric and CBMN assays in a mouse model. Health Physics 98:218–227.
  • Demidenko E, Williams BB, Sucheta A, Dong R, Swartz HM. 2007. Radiation dose reconstruction from L-band in vivo EPR spectroscopy of intact teeth: Comparison of methods. Radiation Measurements 42:1089–1093.
  • Desrosiers M, Schauer DA. 2001. Electron paramagnetic resonance (EPR) biodosimetry. Nuclear Instruments and Methods in Physics Research B 184:219–228.
  • Dons RF, Cerveny TJ. 1989. Triage and treatment of radiation-injured mass casualties. Medical consequences of nuclear warfare. Part I, Vol. 2. Textbook of military medicineIn: Walker RI, Cerveny TJ, editors. Falls Church, VA: TMM Publications, Office of the Surgeon General.
  • Draper NR, Smith H. 1998. Applied regression analysis. 3rd edNew York: Wiley. pp 83–86.
  • Fattibene P, Callens F. 2010. EPR dosimetry with tooth enamel: A review. Applied Radiation and Isotopes 68:2033–2116.
  • Fenech M. 2010. The lymphocyte cytokinesis-block micronucleus cytome assay and its application in radiation biodosimetry. Health Physics 98:234–243.
  • Flegal FN, Devantier Y, McNamee JP, Wilkins R. 2010. Quickscan dicentric chromosome analysis for radiation biodosimetry. Health Physics 98:276–281.
  • Flood AB, Bhattacharyya S, Nicolalde RJ, Swartz HM. 2007. Implementing EPR dosimetry for life-threatening incidents: Factors beyond technical performance. Radiation Measurements 42:1099–1109.
  • Garty G, Chen Y, Salerno A, Turner H, Zhang J, Lyulko OV, Bertucci A, Xu Y, Wang H, Simaan N, Randers-Pehrson G, Yao L, Amundson SA, Brenner DJ. 2010. The RABIT: A Rapid Automated Biodosimetry Tool for Radiological Triage. Health Physics 98:209–217.
  • Goans RE, Holloway EC, Berger ME, Ricks RC. 2001. Early dose assessment in criticality accidents. Health Physics 81:446–449.
  • Goans RE, Holloway EC, Berger ME, Ricks RE. 1997. Early dose assessment following severe radiation accidents. Health Physics 72:513–518.
  • González AJ. 2007. An international perspective on radiological threats and the need for retrospective biological dosimetry of acute radiation overexposures. Radiation Measurements 42:1053–1062.
  • Grace MB, Moyer BR, Prasher J, Cliffer KD, Ramakrishnan N, Kaminski J, Coleman N, Manning RG, Maidment BW, Hatchett R. 2010. Rapid radiation dose assessment for radiological public health emergencies: Roles of NIAID and BARDA. Health Physics 98:172–178.
  • Hirata H, Walczak T, Swartz HM. 2000. Electronically tunable surface-coil-type resonator for L-band EPR spectroscopy. Journal of Magnetic Resonance 142:159–167.
  • International Atomic Energy Agency (IAEA). 2005. Generic procedures for medical response during a nuclear or radiological emergency. Vienna: IAEA, EPR-Medical.
  • International Atomic Energy Agency (IAEA). 2002. Use of electron paramagnetic resonance dosimetry with tooth enamel for retrospective dose assessment. Vienna: IAEA; IAEA-TECDOC-1331.
  • Ivannikov AI, Skvortzov VG, Stepanenko VF, Tikunov DD, Fedosov IM, Romanyukha AA, Wieser A. 1997 Wide-scale EPR retrospective dosimetry: Results and problems. Radiation Protection Dosimetry 71:175–180.
  • Iwasaki A, Walczak T, Grinberg O, Swartz HM. 2005a. Differentiation of the observed low frequency (1200 MHz) EPR signals in whole human teeth. Applied Radiation and Isotopes 62:133–139.
  • Iwasaki A, Grinberg O, Walczak T, Swartz HM. 2005b. In vivo measurements of EPR signals in whole human teeth. Applied Radiation and Isotopes 62:187–190.
  • Kaspler P, Hyrien O, Hill R. 2010. Dynamics of micronuclei in mouse skin fibroblasts after gamma irradiation. Health Physics 98:228–233.
  • Liidja G, Past J, Puskar J, Lippmaa E. 1996. Paramagnetic resonance in tooth enamel created by ultraviolet light. Applied Radiation and Isotopes 47:785–788.
  • Long XH, Zhao ZQ, He XP, Wang HP, Xu QZ, An J, Bai B, Sui JL, Zhou PK. 2007. Dose-dependent expression changes of early response genes to ionizing radiation in human lymphoblastoid cells. International Journal of Molecular Medicine 19:607–615.
  • Nakamura N, Katanic, JF, Miyazawa C. 1998. Contamination from possible solar light exposures in ESR dosimetry using human tooth enamel. Journal of Radiation Research 39:185–191.
  • Nicolalde RJ, Gougelet RM, Rea M, Williams BB, Dong R, Kmiec MM, Lesniewski PN, Swartz HM. 2010. The view from the trenches: Part 2 – technical considerations for EPR screening. Health Physics 98(2):128–135.
  • Nilsson J, Lund E, Lund A. 2001 The effects of UV-irradiation on ESR-dosimetry of tooth enamel. Applied Radiation and Isotopes 54:131–139.
  • Ossetrova N, Sandgren DJ, Gallego S, Blakely WF. 2010. Combined approach of hematological biomarkers and plasma protein SAA for improvement of radiation dose assessment in triage biodosimetry applications. Health Physics 98:204–208.
  • Pollock JD, Williams BB, Sidabras J, Grinberg O, Salikhov I, Lesniewski P, Kmiec M, Swartz HM. 2010. Surface Loop Resonator Design for In Vivo EPR Tooth Dosimetry using Finite Element Analysis. Health Physics 98:339–344.
  • Salikhov I, Hirata H, Walczak T, Swartz HM. 2003. An improved external loop resonator for in vivo L-band EPR spectroscopy. Journal of Magnetic Resonance 164:54–59.
  • Salikhov I, Walczak T, Lesniewski P, Khan N, Iwasaki A, Comi R, Buckey J, Swartz HM. 2005. EPR spectrometer for clinical applications. Magnetic Resonance in Medicine 54:1317–1320.
  • Sasaki MS. 2009. Advances in the biophysical and molecular bases of radiation cytogenetics. International Journal of Radiation Biology 85(1):26–47.
  • Sealy RC, Hyde JS, Antholine WE. 1985. Electron spin resonance. Modern physical methods in biochemistry, Part A In: Neuberger, Van Deenen, editors. New York: Elsevier Science Publishers. pp 69–148.
  • Sharma M, Halligan BD, Wakim BT, Savin VJ, Cohen EP, Moulder JE. 2010. The urine proteome for radiation biodosimetry: Effect of total body versus local kidney irradiation. Health Physics 98:186–195.
  • Sholom S, Desrosiers M, Chumak VV, Luckyanov N, Simon SL, Boiville A. 2010. UV effects in tooth enamel and their possible application in EPR dosimetry with front teeth. Health Physics 98:360–368.
  • Sholom SV, Chumak VV, Pasalskaja LF. 2000. Some aspects of EPR dosimetry of liquidators. Applied Radiation and Isotopes 52:1283–1286.
  • Swartz HM, Iwasaki A, Walczak T, Demidenko E, Salikhov I, Khan N, Lesniewski P, Thomas J, Romanyukha A, Schauer D, Starewicz P. 2006. In vivo EPR dosimetry to quantify exposures to clinically significant doses of ionizing radiation. Radiation Protection Dosimetry 120:163–170.
  • Swartz HM, Iwasaki A, Walczak T, Demidenko E, Salikhov I, Lesniewski P, Starewicz P, Schauer D, Romanyukha A. 2005. Measurements of clinically significant doses of ionizing radiation using non-invasive in vivo EPR spectroscopy of teeth in situ. Applied Radiation and Isotopes 62:293–299.
  • Swartz HM, Burke G, Coey M, Demidenko E, Dong R, Grinberg O, Hilton J, Iwasaki A, Lesniewski P, Kmiec M, Lo K-M, Nicolalde RJ, Ruuge A, Sakata Y, Sucheta A, Walczak T, Williams BB, Mitchell CA, Romanyukha A, Schauer DA. 2007. In vivo EPR for dosimetry. Radiation Measurements 42:1075–1084.
  • Swartz HM, Khan N, Buckey J, Comi R, Gould L, Grinberg O, Hartford A, Hopf H, Hou H, Hug E, Iwasaki A, Lesniewski P, Salikhov I, Walczak T. 2004. Clinical applications of EPR: Overview and perspectives. NMR in Biomedicine 17:335–351.
  • Swartz HM, Flood AB, Gougelet RM, Rea ME, Nicolalde RJ, Williams BB. 2010. A critical assessment of biodosimetry methods for large-scale incidents. Health Physics 98:95–108.
  • Walczak T, Lesniewski P, Salikhov I, Sucheta A, Szybinski K, Swartz HM. 2005. L-band electron paramagnetic resonance spectrometer for use in vivo and in studies of aqueous biological samples. Review of Scientific Instruments 76:013107.
  • Waselenko JK, MacVittie TJ, Blakely WF, Pesik N, Wiley AL, Dickerson WE, Tsu H, Confer DL, Coleman CN, Seed T, Lowry P, Armitage JO, Dainiak N. 2004. Strategic National Stockpile Radiation Working Group. Medical management of the acute radiation syndrome: Recommendations of the Strategic National Stockpile Radiation Working Group. Annals of Internal Medicine 15;140:1037–1051.
  • Williams BB, Dong R, Kmiec M, Burke G, Demidenko E, Gladstone D, Nicolalde RJ, Sucheta A, Lesniewski P, Swartz HM. 2010. Development of in vivo tooth EPR for individual radiation dose estimation and screening. Health Physics 98:327–338.
  • Williams BB, Sucheta A, Dong R, Sakata Y, Iwasaki A, Burke G, Grinberg O, Lesniewski P, Kmiec M, Swartz HM. 2007. Experimental procedures for sensitive and reproducible in situ EPR tooth dosimetry. Radiation Measurements 42:1094–1098.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.