92
Views
2
CrossRef citations to date
0
Altmetric
Research Article

Automatic bone removal for 3D TACE planning with C-arm CBCT: Evaluation of technical feasibility

, , , , , , , , & show all
Pages 162-170 | Received 27 Mar 2015, Accepted 07 Nov 2015, Published online: 29 Feb 2016

References

  • Yamakado K, Miyayama S, Hirota S, Mizunuma K, Nakamura K, Inaba Y, et al. Hepatic arterial embolization for unresectable hepatocellular carcinomas: do technical factors affect prognosis? Jpn J Radiol 2012;30:560–6.
  • Miyayama S, Mitsui T, Zen Y, Sudo Y, Yamashiro M, Okuda M, et al. Histopathological findings after ultraselective transcatheter arterial chemoembolization for hepatocellular carcinoma. Hepatol Res 2009;39:374–81.
  • Iwamoto S, Yamaguchi T, Hongo O, Iwamoto H, Sanefuji H. Excellent outcomes with angiographic subsegmentectomy in the treatment of typical hepatocellular carcinoma: a retrospective study of local recurrence and long-term survival rates in 120 patients with hepatocellular carcinoma. Cancer 2010;116:393–9.
  • Schernthaner R, Lin M, Duran R, Chapiro J, Wang Z, Geschwind JF. Delayed-phase Cone-Beam CT improves detectability of intrahepatic cholangiocarcinoma during conventional transarterial chemoembolization. Cardiovasc Intervent Radio 2015;38:929–36.
  • Deschamps F, Solomon SB, Thornton RH, Rao P, Hakime A, Kuoch V, et al. Computed analysis of three-dimensional Cone-Beam computed tomography angiography for determination of tumor-feeding vessels during chemoembolization of liver tumor: A pilot study. Cardiovasc Intervent Radiol 2010;33:1235–42.
  • Miyayama S, Yamashiro M, Hattori Y, Orito N, Matsui K, Tsuji K, et al. Efficacy of cone-beam computed tomography during transcatheter arterial chemoembolization for hepatocellular carcinoma. Jpn J Radiol 2011;29:371–7.
  • Tognolini A, Louie J, Hwang G, Hofmann L, Sze D, Kothary N. C-arm computed tomography for hepatic interventions: a practical guide. J Vasc Interv Radiol 2010;21:1817–23.
  • Lin M, Loffroy R, Noordhoek N, Taguchi K, Radaelli A, Blijd J, et al. Evaluating tumors in transcatheter arterial chemoembolization (TACE) using dual-phase cone-beam CT. Minim Invasive Ther Allied Technol 2011;20:276–81.
  • Loffroy R, Lin M, Yenokyan G, Rao PP, Bhagat N, Noordhoek N, et al. Intraprocedural C-arm dual-phase cone-beam CT: can it be used to predict short-term response to TACE with drug-eluting beads in patients with hepatocellular carcinoma? Radiology 2013;266:636–48.
  • Wang Z, Lin M, Lesage D, Chen R, Chapiro J, Gu T, et al. Three-dimensional evaluation of lipiodol retention in HCC after chemoembolization: A quantitative comparison between CBCT and MDCT. Acad Radiol 2014;21: 393–9.
  • Iwazawa J, Ohue S, Hashimoto N, Muramoto O, Mitani T. Survival after c-arm CT-assisted chemoembolization of unresectable hepatocellular carcinoma. Eur J Radiol 2012;81:3985–92.
  • Tacher V, Radaelli A, Lin M, Geschwind JF. How I do it: Cone beam computer tomography during transarterial chemoembolization for liver cancer. Radiology 2015;274:320–34.
  • Tacher V, Lin M, Bhagat N, Radaelli A, Noordhoek N, Carelsen B, et al. Dual-phase cone-beam computed tomography to see, reach, and treat hepatocellular carcinoma during drug-eluting beads transarterial chemo-embolization. Journal of visualized experiments: JoVE 2013;82:50795.
  • Miyayama S, Yamashiro M, Hashimoto M, Hashimoto N, Ikuno M, Okumura K, et al. Identification of small hepatocellular carcinoma and tumor-feeding branches with cone-beam CT guidance technology during transcatheter arterial chemoembolization. J Vasc Interv Radiol 2013;24:501–8.
  • Wang X, Shah RP, Maybody M, Brown KT, Getrajdman GI, Stevenson C, et al. Cystic artery localization with a three-dimensional angiography vessel tracking system compared with conventional two-dimensional angiography. J Vasc Interv Radiol 2011;22:1414–19.
  • Iwazawa J, Ohue S, Hashimoto N, Muramoto O, Mitani T. Clinical utility and limitations of tumor-feeder detection software for liver cancer embolization. Eur J Radiol 2013;82:1665–71.
  • Hansis E RA, Noordhoek N, Grass M. Automatic bone removal for 3D liver TACE planning with C-arm CT. Proc IEEE ISBI 2013:1408–11.
  • Feldkamp LA DLC, Kress JW. Practical cone-beam algorithms. J Opt Soc Am 1984;A6:612–19.
  • Grass M, Koppe R, Klotz E, Proksa R, Kuhn M.H, Aerts H, et al. Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data. Comput Med Imaging Graph 1999;23:311–21.
  • Lorenz C, Schäer D, Eshuis P, Carroll J, Grass M. Automated volume of interest delineation and rendering of cone beam CT images in interventional cardiology. Proc SPIE 2012:8316.
  • Ecabert O, Peters J, Schramm H, Lorenz C, von Berg J, Walker MJ, et al. Automatic model-based segmentation of the heart in CT images. IEEE Trans Med Imaging 2008; 27:1189–201.
  • Peters J, Ecabert O, Meyer C, Kneser R, Weese J. Optimizing boundary detection via Simulated Search with applications to multi-modal heart segmentation. Med Image Anal 2010;14:70–84.
  • Miyayama S, Yamashiro M, Okuda M, Yoshie Y, Sugimori N, Igarashi S, et al. Usefulness of cone-beam computed tomography during ultraselective transcatheter arterial chemoembolization for small hepatocellular carcinomas that cannot be demonstrated on angiography. Cardiovasc Intervent Radiol 2009;32:255–64.
  • Schernthaner R, Chapiro J, Sahu S, Withagen P, Duran R, Sohn J, et al. Feasibility of a modified cone-beam CT rotation trajectory to improve liver periphery visualization during transarterial chemoembolization. Radiology 2015;277:833–41.
  • Abdelmaksoud MH, Louie JD, Hwang GL, Sze DY, Hofmann LV, Kothary N. Transarterial chemoembolization for hepatocellular carcinomas in watershed segments: utility of C-arm computed tomography for treatment planning. J Vasc Interv Radiol 2012;23:281–3.
  • Kakeda S, Korogi Y, Ohnari N, Moriya J, Oda N, Nishino K, et al. Usefulness of cone-beam volume CT with flat panel detectors in conjunction with catheter angiography for transcatheter arterial embolization. J Vasc Interv Radiol 2007;18:1508–16.
  • Meyer BC, Witschel M, Frericks BB, Voges M, Hopfenmüller W, Wolf KJ, et al. The value of combined soft-tissue and vessel visualisation before transarterial chemoembolisation of the liver using C-arm computed tomography. Eur Radiol 2009;19:2302–9.
  • Kang Y, Engelke K, Kalender WA. A new accurate and precise 3-D segmentation method for skeletal structures in volumetric CT data. IEEE transactions on medical imaging 2003; 22:586–98.
  • Wang LI, Greenspan M, Ellis R. Validation of bone segmentation and improved 3-D registration using contour coherency in CT data. IEEE transactions on medical imaging 2006;25:324–34.
  • Hahn H. K WMT, Drexl J, et al. HWT-hybrid watershed transform: optimal combination of hierarchical interactive and automated image segmentation. In Proc SPIE Med Imag. 2007:65120Z–Z.
  • Heath DG, Hahn HK, Johnson PT, Fishman EK. Automated multidetector row CT dataset segmentation with an interactive watershed transform (IWT) algorithm: Part 1. Understanding the IWT technique. Journal of digital imaging 2008;21:408–12.
  • Johnson PT, Hahn HK, Heath DG, Fishman EK. Automated multidetector row CT dataset segmentation with an interactive watershed transform (IWT) algorithm: Part 2. Body CT angiographic and orthopedic applications. Journal of digital imaging 2008;21:413–21.
  • Van Straten M, Venema HW, Streekstra GJ, Majoie CB, den Heeten GJ, Grimbergen CA. Removal of bone in CT angiography of the cervical arteries by piecewise matched mask bone elimination. Medical physics 2004;31: 2924–33.
  • Tomandl BF, Hammen T, Klotz E, Ditt H, Stemper B, Lell M. Bone-subtraction CT angiography for the evaluation of intracranial aneurysms. Am J Neuroradiol 2006;27:55–9.
  • Deng K, Liu C, Ma R, Sun C, Wang XM, et al. Clinical evaluation of dual-energy bone removal in CT angiography of the head and neck: comparison with conventional bone-subtraction CT angiography. Clin Radiol 2009;64:534–41.
  • Klinder T, Lorenz C, von Berg J, Dries SP, Bulow T, Ostermann J. Automated model-based rib cage segmentation and labeling in CT images. Medical image computing and computer-assisted intervention: MICCAI International Conference on Medical Image Computing and Computer-Assisted Intervention. 2007;10:195–202.
  • Klinder T, Ostermann J, Ehm M, Franz A, Kneser R, Lorenz C. Automated model-based vertebra detection, identification, and segmentation in CT images. Medical image analysis 2009;13:471–82.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.