Publication Cover
The Ultrasound Review of Obstetrics and Gynecology
the international journal of continuing education and current awareness
Volume 6, 2006 - Issue 3-4
14
Views
4
CrossRef citations to date
0
Altmetric
Original Article

Modern 3D/4D sonographic studies on fetal heart

Pages 115-122 | Received 26 Feb 2006, Accepted 02 Mar 2006, Published online: 04 Dec 2011

References

  • Deng J, Gardener JE, Rodeck CH, Lees WR. Fetal echocar-diography in three and four dimensions. Ultrasound Med Biol 1996;22:979–986.
  • Sklansky MS, Nelson TR, Pretorius DH. Usefulness of gated three-dimensional fetal echocardiography to reconstruct and display structures not visualized with two-dimensional imaging. Am J Cardiol 1997;80:665–668.
  • Meyer-Wittkopf M, Rappe N, Sierra F, Barth H, Schmidt S. Three-dimensional (3-D) ultrasonography for obtaining the four and five-chamber view: comparison with cross-sectional (2-D) fetal sonographic screening. Ultrasound Obstet Gynecol 2000;15:397–402.
  • Meyer-Wittkopf M, Cooper S, Vaughan J, Sholler G. Three-dimensional (3D) echocardiographic analysis of congenital heart disease in the fetus: comparison with cross-sectional (2D) fetal echocardiography. Ultrasound Obstet Gynecol 2001;17:485–492.
  • Ge S. 3D echocardiography. Clinical application in pediatric cardiology. Pediatr Ultrasound Today 2002;7:145–164.
  • Gill EA. Live three-dimensional echo—A major incremental step in the development of cardiac ultrasound. J Cardiovasc Manage 2003;14:13–17.
  • Forrest W. Roberto M. Lange MD. Echocardiography closes in on 3D as it turns 50. Medical Imaging 2003; 18:C64210-C64212.
  • Maulik D, Nanda NC, Singh V, Dod H, Vengala S, Sinha A, Sidhu MS, Khanna D, Lysikiewicz A, Sicuranza G, Modh N. Live three-dimensional echocardiography of the human fetus. Echocardiography 2003;20:715–721.
  • Sklansky MS, DeVore GR, Wong PC. Real-time 3-dimensional fetal echocardiography with an instantaneous volume-rendered display. J Ultrasound Med 2004;23:283–289.
  • Sklansky MS, Miller D, DeVore GR, Kung G, Pretorius D, Wong PC, Chang RK. Prenatal screening for congenital heart disease using real-time three-dimensional echocardiography and a novel ‘sweep volume’ acquisition technique. Ultrasound Obstet Gynecol 2005;25:435–443.
  • Hata T, Kanenishi K, Tanaka H, Kimura K. Real-time three-dimensional echocardiographic evaluation of fetal heart using instantaneous volume-rendered display. J Obstet Gynecol Res 2006; 32:42–46.
  • Marx GR. The real deal: real-time 3-D echocardiography in congenital heart disease. Pediatr Cardiol Today 2003;1:9–11.
  • Gonc¸alves LF, Lee W, Chaiworapongsa T, Espinoza J, Schoen ML, Falkensammer P, Treadwell M, Romero R. Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation. Am J Obstet Gynecol 2003; 189:1792–1902.
  • DeVore GR, Falkensammer P, Sklansky MS, Platts LD. Spatio-temporal image correlation (STIC): new technology for evaluation of the fetal heart. Ultrasound Obstet Gynecol 2003;22:380–387.
  • Vin˜ als F, Poblete P, Giuliano A. Spatio-temporal image correlation (STIC): a new tool for the prenatal screening of congenital heart defects. Ultrasound Obstet Gynecol 2003; 22:388–394.
  • Deng J. Terminology of three-dimensional and four-dimensional ultrasound imaging of the fetal heart and other moving body parts. Ultrasound Obstet Gynecol 2003; 22:336–344.
  • Deng J, Rodeck CH. New fetal cardiac imaging techniques. Prenat Diagn 2004;24:1092–1103.
  • Michailides GD, Simpson JM, Karidas C, Economides DL. Detailed three-dimensional fetal echocardiography facilitated by an Internet link. Ultrasound Obstet Gynecol 2001;18:325–328.
  • Vin˜ als F, Mandujano L, Vargas G, Giuliano A. Prenatal diagnosis of congenital heart disease using four-dimensional spatio-temporal image correlation (STIC) telemedicine via an Internet link: a pilot study. Ultrasound Obstet Gynecol 2005; 25:25–31.
  • Chaoui R, Heling KS. New developments in fetal heart scanning: Three-and four-dimensional fetal echocardiography. Semin Fetal Neonatal Med 2005;10:567–577.
  • Downey DB, Fenster A. Vascular imaging with a three-dimensional power Doppler system. Am J Roentgenol 1995; 165:665–668.
  • Bailao LA. Technologies converge in 3-D power Doppler. Diagn Imag 1996;3:19–21.
  • Ritchie CJ, Edwards WS, Mack LA, Cyr DR, Kim Y. Three-dimensional ultrasonic angiography using power-mode Doppler. Ultrasound Med Biol 1996;22:277–286.
  • Fenster A, Lee D, Sherebrin S, Rankin R, Downey D. Three-dimensional ultrasound imaging of the vasculature. Ultrasonics 1998;36:629–633.
  • Pretorius DH, Nelson TR, Baergen RN, Pai E, Cantrell C. Imaging of placental vasculature using three-dimensional ultrasound and color power Doppler: a preliminary study. Ultrasound Obstet Gynecol 1998;12:45–49.
  • Kurjak A, Kupesic S, Banovic I, Hafner T, Kos M. The study of morphology and circulation of early embryo by three-dimensional ultrasound and power Doppler. J Perinat Med 1999;27:145–147.
  • Hata T, Inubashiri E, Kanenishi K, Akiyama M, Tanaka H, Yanagihara T. Three-dimensional power Doppler angio-graphic features of placental chorioangioma. J Ultrasound Med 2004;23:1517–1520.
  • Chaoui R, Kalache KD, Hartung J. Application of three-dimensional power Doppler ultrasound in prenatal diagnosis. Ultrasound Obstet Gynecol 2001;17:22–29.
  • Chaoui R, Kalache KD. Three-dimensional power Doppler ultrasound of the fetal great vessels. Ultrasound Obstet Gynecol 2001;17:455–456.
  • Chaoui R, Schneider MBE, Kalache KD. Right aortic arch with vascular ring and aberrant left subclavian artery: prenatal diagnosis assisted by three-dimensional power Doppler ultrasound. Ultrasound Obstet Gynecol 2003;22:661–663.
  • Gonc¸alves LF, Romero R, Espinoza J, Lee W, Treadwell M, Chintala K, Brandl H, Chaiworapongsa T. Four-dimensional ultrasonography of the fetal heart using color Doppler spatio-temporal image correlation. J Ultrasound Med 2004;23:473–481.
  • Chaoui R, Hoffmann J, Heling KS. Three-dimensional (3D) and 4D color Doppler fetal echocardiography using spatio-temporal image correlation (STIC). Ultrasound Obstet Gynecol 2004;23:535–545.
  • Gonc¸alves LF, Espinoza J, Romero R, Lee W, Beyer B, Treadwell MC, Humes R. A systematic approach to prenatal diagnosis of transposition of the great arteries using 4-dimensional ultrasonography with spatiotemporal image correlation. J Ultrasound Med 2004;23:1225–1231.
  • Yagel S, Valsky DV, Messing B. Detailed assessment of fetal ventricular septal defect with 4D color Doppler ultra-sound using spatio-temporal image correlation technology. Ultrasound Obstet Gynecol 2005;25:97–98.
  • Wachsberg RH. B-flow, a non-Doppler technology for flow mapping: early experience in the abdomen. Ultrasound Quarterly 2003;19:114–122.
  • Furuse J, Maru Y, Mera K, Sumi H, Yoshino M, Yokoyama Y, Hashimoto H, Ejiri A. Visualization of blood flow in hepatic vessels and hepatocellular carcinoma using B-flow sonography. J Clin Ultrasound 2001;29:1–6.
  • Weskott HP. B-flow—a new method for detecting blood flow. Ultraschall Med 2000;21:59–65.
  • Pooh RK. New application of B-flow sono-angiography in perinatology. Ultrasound Obstet Gynecol 2000;15:163.
  • Deng J, Rodeck CH. New fetal cardiac imaging techniques. Prenat Diagn 2004;24:1092–1103.
  • Gonc¸alves LF, Espinoza J, Lee W, Nien JK, Hong JS, Santolaya-Forgas J, Mazor M, Romero R. A new approach to fetal echocardiography: digital casts of the fetal cardiac chambers and great vessels for detection of congenital heart disease. J Ultrasound Med 2005;24:415–424.
  • Pooh RK, Korai A. B-flow and B-flow spatio-temporal image correlation in visualizing fetal cardiac blood flow. Croat Med J 2005;46:808–811.
  • Gonc¸alves LF, Espinoza J, Lee W, Mazor M, Romero R. Three-and four-dimensional reconstruction of the aortic arches using inversion mode: a new rendering algorithm for visualization of fluid-filled anatomical structures. Ultrasound Obstet Gynecol 2004;24:696–698.
  • Lee W, Gonc¸alves LF, Espinoza J, Romero R. Inversion mode: a new volume analysis tool for 3-dimensional ultra-sonography. J Ultrasound Med 2005;24:201–207.
  • Espinoza J, Gonc¸alves LF, Lee W, Mazor M, Romero R. A novel method to improve prenatal diagnosis of abnor-mal systemic venous connections using three-and four-dimensional ultrasonography and ‘inversion mode’. Ultrasound Obstet Gynecol 2005;25:428–434.
  • Ghi T, Cera E, Segata M, Michelacci L, Pilu G, Pelusi G. Inversion mode spatio-temporal image correlation (STIC) echocardiography in three-dimensional rendering of fetal ventricular septal defects. Ultrasound Obstet Gynecol 2005; 26:679–686.
  • Wilkins-Haug LE, Benson CB, Tworetzky W, Marshall AC, Jennings RW, Lock JE. In-utero intervention for hypo-plastic left heart syndrome—a perinatologist’s perspective. Ultrasound Obstet Gynecol 2005;26:481–486.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.