References
- Bamford J. Wilson I. 1979. Methodological considerations and practical aspects of the BKB Sentence Lists. J. Bench J. Bamford Speech-hearing Tests and the Spoken Language of Hearing-impaired Children. London: Academic Press, 147–187.
- Bigelow D.C., Kay D.J., Rafter K.O., Montes M., Knox G.W. . 1998. Facial nerve stimulation from cochlear implants. Am J Otol, 19(2), 163–9.
- Boyd P.J. 2006. Effects of programming threshold and maplaw settings on acoustic thresholds and speech discrimination with the MED-EL COMBI 40+ cochlear implant. Ear Hear, 27(6), 608–618.
- Bresnihan M., Norman G., Scott F. Viani L. 2001. Measurement of comfort levels by means of electrical stapedial reflex in children. Arch Otolaryngol Head Neck Surg, 127(8), 963–6.
- Brickley G., Boyd P., Wyllie F., O'Driscoll M., Webster D. . 2005. Investigations into electrically evoked stapedius reflex measures and subjective loudness percepts in the MED-EL COMBI 40+ cochlear implant. Cochlear Implants International, 6(1), 31–42.
- Brill S.M., Gstottner W., Helms J. . 1997. Optimization of channel number and stimulation rate for the fast continuous interleaved strategy in the COMBI 40+. Am J Otol, 18(6 suppl.), S104–106.
- Brown C.J., Abbas P.J., Fryauf-Bertschy H., Delsay D. Gantz B.J. 1994. Intraoperative and postoperative electrically evoked brainstem responses in Nucleus cochlear implant users: Implications for the fitting process. Ear Hear, 15, 168–176.
- Dawson P.W., Skok S.M. Clark M. 1997. The effect of loudness imbalance between electrodes in cochlear implant users. Ear Hear, 18, 156–165.
- Gani M., Valentini G., Sigrist A. . 2007. Implications of deep electrode insertion on cochlear implant fitting. J Assoc Res Otolaryngol, 8(1), 69–83.
- Garnham C., O'Driscoll M., Ramsden R. . 2002. Speech understanding in noise with a MED-EL COMBI 40+ cochlear implant using reduced channel sets. Ear Hear, 23(6), 540–552.
- Gatehouse S. 1993. Role of perceptual acclimatization in the selection of frequency responses for hearing aids. J Am Acad Audiol, 4(5), 296–306.
- Henkin Y., Kaplan-Neeman R., Muchnik C., Kronenberg J. Hildesheimer, M. 2003. Changes over time in the psycho-electric parameters in children with cochlear implants. Int J Audiol, 42(5), 274–278.
- Henkin Y., Kaplan-Neeman R., Kronenberg J., Migirov L., Hildesheimer M. . 2006. A longitudinal study of electrical stimulation levels and electrode impedance in children using the Clarion cochlear implant. Acta Otolaryngol, 126(6), 581–586.
- Hughes M.L., Vander Werff K.R., Brown C.J., Abbas P.J., Kelsay D.M. . 2001. A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in Nucleus 24 cochlear implant users. Ear Hear, 22(6), 471–486.
- Iwasaki S., Atsumi K., Ocho S. . 1998. Facial nerve stimulation by a cochlear implant in a haemodialysis patient with bone of low mineral density. Eur Arch Otorhinolaryngol, 2565(7), 352–354.
- Kempf H.G., Johann K., Weber B.P. Lenarz T. 1997. Complications of cochlear implant surgery in children. Am J Otol, 18(6 Suppl.), S62–3.
- Lawson D.T., Wilson B.S., Finley C.C. . 1997. Cochlear implant studies at Research Triangle Institute and Duke University Medical Center. Scand Audiol Suppl, 46, 50–64.
- Morita T., Naito Y., Hirai T., Yamaguchi S. Ito J. 2003. The relationship between the intraoperative ECAP threshold and postoperative behavioural levels: The difference between postlingually deafened adults and prelingually deafened pediatric cochlear implant users. Eur Arch Otorhinolaryngol, 260(2), 67–72.
- Munro K.M., Walker A.J. Purdy S.C. 2007. Evidence for adaptive plasticity in elderly monaural hearing aid users. Neuro Rep, 18(12), 1237–1240.
- Nie K., Barco A. Zeng F.G. 2006. Spectral and temporal cues in cochlear implant speech perception. Ear Hear, 27(2), 8–17.
- Niparko J.K., Oviatt D.L., Coker N.J. . 1991. Facial nerve stimulation with cochlear implantation. VA Cooperative Study Group on Cochlear Implantation. Otolaryngol Head Neck Surg, 104(6), 826–830.
- Pfingst B.E. Xu L. 2004. Across-site variation in detection thresholds and maximum comfortable loudness levels for cochlear implants. J Assoc Res Otolaryngol, 5(1), 11–24.
- Sainz M., de la Torre A., Roldan C. . 2003. Analysis of programming maps and its application for balancing multichannel cochlear implants. Int J Audiol, 42, 43–51.
- Schmidt M. Griesser A. 1997. Long-term stability of fitting parameters with the COMBI 40. Am J Otol, 18(6), S109–110.
- Shallop J.K., Facer G.W. Peterson A. 1999. Neural response telemetry with the nucleus CI24M cochlear implant. Laryngoscope, 109(11), 1755–9.
- Spahr A.J. Dorman M.F. 2005. Effects of minimum stimulation settings for the Med El Tempo+ speech processor on speech understanding. Ear Hear, 26, 2S–6S.
- Tyler R.S., Preece J.P., Lansing C.R., Otto S.R. Gantz B.J. 1986. Previous experience as a confounding factor in comparing cochlear-implant processing schemes. J Speech Hear Res, 29, 282–287.
- Walravens E., Mawman D. O'Driscoll M. 2006. Changes in psychophysical parameters during the first month of programming the Nucleus Contour and Contour Advance cochlear implants. Cochlear Implants Int, 7(1), 15–32.