- Arlinger S., Kinnefors C. 1989. Reference equivalent threshold sound pressure levels for insert earphones. Scand Audiol, 18, 195–198.
- Brinkmann, K., Richter, U. 1990. Reference zero for the calibration of pure tone audiometers equipped with insert earphones. Acustica, 70, 202–207.
- Cox J., Bilger R.C. 1960. Suggestion relative to the standardization of loudness-balance data for the Telephonics TDH-39 earphone. J Acoust Soc Am, 32, 1081–1082.
- Fearn R.W., Hanson D.R. 1983. Audiometric zero for air conduction using manual audiometry. Br J Audiol, 17, 87–89.
- Fedtke T. 2008. Test report: Determination of reference equivalent threshold sound pressure levels for pure tones of an audiometric headphone. Report, Physikalish-Technische Bundesanstalt. Braunschweig.
- Han L.A., Poulsen T. 1998. Equivalent threshold sound pressure levels for Sennheiser HDA 200 earphone and Etymotic Research ER-2 insert earphone in the Frequency range 125 Hz to 16000 Hz. Scand Audiol, 27, 105–112.
- IEC 60268-7 2009 (FDIS). Sound system equipment – Part 7: Headphones and earphones. International Electrotechnical Commission, Geneva.
- IEC 60318-1 1998. Electroacoustics – Simulators of human head and ear – Part 1: Ear simulator for the calibration of supra-aural earphones. International Electrotechnical Commission, Geneva.
- IEC 60318-3 1998. Electroacoustics – Simulators of human head and ear – Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry. International Electrotechnical Commission, Geneva.
- IEC 60645-1 2001. Electroacoustics – Audiological equipment – Part 1: Pure-tone audiometers. International Electrotechnical Commission, Geneva.
- ISO 389-1 1998. Acoustics – Reference zero for the calibration of audiometric equipment - Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones. International Organization for Standardisation, Geneva.
- ISO 389-5 2006. Acoustics – Reference zero for the calibration of audiometric equipment - Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz. International Organization for Standardization, Geneva.
- ISO 389-8 2004. Acoustics – Reference zero for the calibration of audiometric equipment - Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones. International Organization for Standardization, Geneva.
- ISO 389-9 2007. Acoustics – Reference zero for the calibration of audiometric equipment - Part 9: Preferred test conditions for the determination of reference hearing threshold levels. International Organization for Standardization, Geneva.
- ISO 4869-3 2007. Acoustics – Hearing Protectors - Part 3: Measurement of insertion loss of ear-muff type protectors using an acoustic test fixture. International Organization for Standardization, Geneva.
- ISO 8253-1 1989. Acoustics – Audiometric test methods – Part 1: Basic pure tone air and bone conduction threshold audiometry. International Organization for Standardization, Geneva.
- Lawton B. 2005. Variation of young normal-hearing thresholds measured using different audiometric earphones: Implications for the acoustic coupler and the ear simulator. Int J Audiol, 44, 444–451.
- Michael P.L., Bienvenue G.R. 1980. A comparison of acoustical performance between a new one-piece earphone cushion and the conventional two-piece MX-41/AR cushion. J Acoust Soc Am, 67, 693–698.
- Poulsen T. 1991. Reference thresholds for Eartone 3A insert earphones. Scand Audiol, 20, 205–207.
- Poulsen T., Oakley S. 2009. Equivalent threshold sound pressure levels (ETSPL) for Sennheiser HDA 280 supra-aural audiometric earphones in the frequency range 125 Hz to 8000 Hz. Int J Audiol, 48, 271–276.
- Robinson D.W., Shipton M.S., Hinchcliffe R. 1981. Audiometric zero for air conduction: A verification and critique of international standards. Int J Audiol, 20, 409–431.
- Takeshima H., Hiraoka T., Kumagai M., Sone T., Suzuki Y. 1995. Reference equivalent threshold sound pressure levels for new earphones. Proceedings, 15th International Congress of Acoustics, Trondheim, Norway.
- Weissler P.G. 1968. International standard reference zero for audiometers. J Acoust Soc Am, 44, 264–275.