References
- Busby P., Plant K. & Whitford L. 2002. Electrode impedance in adults and children using the Nucleus 24 cochlear implant system. Cochlear Implants Int, 3, 87–103.
- Briggs R.J.S., Tykocinski M., Saunders E., Hellier W., Dahm M.C. et al. 2001. Surgical implications of perimodiolar cochlear implant electrode design: Avoiding intracochlear damage and scala vestibuli insertion. Cochlear Implants Int, 2, 135–149.
- Carlson M.L., Archibald D.J., Dabade T.S., Gifford R.H., Neff B.A. et al. 2010. Prevalence and timing of individual cochlear implant electrode failures. Otol Neurotol, 31, 893–898.
- Friedland D.R. & Runge-Samuelson C. 2009. Soft cochlear implantation: Rationale for the surgical approach. Trends in Amplif, 13, 124–138.
- Friesen L.M., Shannon R.V., Baskent D. & Wang X. 2001. Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implants. J Acoust Soc Am, 110, 1150–1163.
- Goehring J.L., Hughes M.L., Baudhuin J.L. & Lusk R.P. 2013. How well do cochlear implant intraoperative impedance measures predict postoperative electrode function? Otol Neurotol, 34, 239–244.
- Hughes M.L., Brown C.J. & Abbas P.J. 2004. Sensitivity and specificity of averaged electrode voltage measures in cochlear implant recipients. Ear Hear, 25, 431–446.
- Liu T.C., Chen H.P. & Lin H.C. 2004. Effects of limiting the number of active electrodes on Mandarin tone perception in young children using cochlear implants. Acta Otolaryngol, 124, 1149–1154.
- Nadol J.B. Jr. & Eddington D.K. 2006. Histopathology of the inner ear relevant to cochlear implantation. Adv Otorhinolaryng, 64, 31–49.
- Newbold C., Richardson R., Millard R., Huang C., Milojevic D. et al. 2010. Changes in biphasic electrode impedance with protein adsorption and cell growth. J Neural Eng, 7, 056011.
- Newbold C., Richardson R., Millard R., Seligman P., Cowan R. et al. 2011. Electrical stimulation causes rapid changes in electrode impedance of cell-covered electrodes. J Neural Eng, 8, 036029.
- Saunders E., Cohen L.T., Aschendorff A., Shapiro W., Knight M. et al. 2002. Threshold, comfortable level and impedance changes as a function of electrode-modiolar distance. Ear Hear, 23(Suppl.), 28S–40S.
- Schulman J.H. 1995. Using impedance telemetry to diagnose cochlear electrode history, location and functionality. Ann Otol Rhinol Laryngol Suppl., 166, 85–87.
- Tan C.T., Svirsky M., Anwar A., Kumar S., Caessens B. et al. 2013. Real-time measurement of electrode impedance during intracochlear electrode insertion. Laryngoscope, 123, 1028–1032.
- Tykocinski M., Cohen L.T. & Cowan R.S. 2005. Measurement and analysis of access resistance and polarization impedance in cochlear implant recipients. Otol Neurotol, 26, 948–956.
- van Wermeskerken G.K., van Olphen A.F. & Smoorenburg G.F. 2006. Intra- and postoperative electrode impedance of the straight and Contour arrays of the Nucleus 24 cochlear implant: Relation to T and C levels. Int J Audiol, 45, 537–544.
- Zeitler D.M., Lalwani A.K., Roland J.T. Jr., Habib M.G., Gudis D. et al. 2009. The effects of cochlear implant electrode deactivation on speech perception and in predicting device failure. Otol Neurotol, 30, 7–13.