1,148
Views
32
CrossRef citations to date
0
Altmetric
Research Article

Quadriceps force after TKA with femoral single radius

An in vitro study

&
Pages 339-343 | Received 04 Nov 2010, Accepted 07 Feb 2011, Published online: 19 Apr 2011

  • Andriacchi TP. Biomechanics and gait analysis in total knee arthroplasty. Orthop Rev 1988; 17:470-3.
  • Andriacchi TP, Galante JO, Fermier RW. The influence of total knee-replacement design on walking and stair-climbing. J Bone Joint Surg (Am) 1982; 64:1328-35.
  • Berman AT, Bosacco SJ, Israelite C. Evaluation of total knee arthroplasty using isokinetic testing. Clin Orthop 1991; (271):106-13.
  • Browne C, Hermida JC, Bergula A, Colwell CW Jr, D'Lima DD. Patellofemoral forces after total knee arthroplasty: effect of extensor moment arm. Knee 2005; 12(2):81-8.
  • Dennis DA. Proposed advantages of posterior cruciate ligament retention. Orthopaedics Today 1998a; 1: 10. New Jersey, Slack Incorporated.
  • Dennis DA, Komistek RD, Colwell CE, Ranawat C, Scott RD, Thornhill TS, Lapp MA. In vivo anteroposterior femorotibial translation of total knee arthroplasty: a multicenter analysis. Clin Orthop 1998b; (356):47-57.
  • Dorr LD. Functional Comparison of posterior of posterior cruciate retaining versus cruciate sacrificed total knee arthroplasty. Clin Orthop 1988; (236):36-41.
  • Fuchs S, Flören M, Tibesku C 1998a O, Jerosch J. Gait analysis of total knee arthroplasty patients compared to healthy volunteers. 1998. Nice, 8th Congress of the European Society of Sports Traumatology, Knee Surgery and Arthroscopy.
  • Fuchs S, Tibesku CO, Genkinger M, Volmer M, Laass H, Rosenbaum D. Clinical and functional comparison of bicondylar sledge prostheses retaining all ligaments and constrained total knee replacement. Clin Biomech (Bristol, Avon) 2004; 19:263-9.
  • Heyse TJ, Becher C, Kron N, Ostermeier S, Hurschler C, Schofer MD, Fuchs-Winkelmann S, Tibesku CO. Quadriceps force in relation of intrinsic anteroposterior stability of TKA design. (epub ahead Arch Orthop Trauma Surg, Jul 4, 2009.
  • Kessler O, Durselen L, Banks S, Mannel H, Marin F. Sagittal curvature of total knee replacements predicts in vivo kinematics. Clin Biomech (Bristol, Avon) 2007; 22:52-8.
  • Lewandowski PJ, Askew MJ, Lin DF, Hurst FW, Melby A. Kinematics of Posterior Cruciate Ligament-retaining and -Sacrificing Mobile Bearing Total Knee Arthroplasties. J Arthroplasty 1997; 12:777-84.
  • Nisell R, Ekholm J. Mechanics of the knee. Acta Orthop Scand (Suppl 216) 1985: 1-42.
  • Ostermeier S, Hurschler C, Stukenborg-Colsman C. Quadriceps function after TKA--an in vitro study in a knee kinematic simulator. Clin Biomech (Bristol, Avon) 2004; 19:270-6.
  • Ostermeier S, Hurschler C, Windhagen H, Stukenborg-Colsman C. In vitro investigation of the influence of tibial slope on quadriceps extension force after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2006; 14:934-9.
  • Ostermeier S, Friesecke C, Fricke S, Hurschler C, Stukenborg-Colsman C. Quadriceps force during knee extension after non-hinged and hinged TKA: an in vitro study. Acta Orthop 2008; 79:34-8.
  • Petersilge WJ, Oishi CS, Kaufman KR, Irby SE, Colwell CW, Jr. The effect of trochlear design on patellofemoral shear and compressive forces in total knee arthroplasty. Clin Orthop 1994; (309):124-30.
  • Stukenborg-Colsman C, Ostermeier S, Wenger K, Wirth CJ. Dynamic in vitro measurements of tibiofemoral contact stress after TKA with fixed and mobile bearing inlays. 10th Annual Conference, European Orthopaedic Research 2000; S 10: O-101.
  • Stukenborg-Colsman C, Ostermeier S, Wenger KH, Wirth CJ. Relative motion of a mobile bearing inlay after total knee arthroplasty–dynamic in vitro study. Clin Biomech (Bristol, Avon) 2002; 17:49-55.
  • Wimmer MA. Wear of the polyethylene component created by rolling motion of the artificial knee joint ( ed. Wimmer MA). Shaker-Verlag, Aachen 1999.