671
Views
9
CrossRef citations to date
0
Altmetric
Research Article

The effect of impaction and a bioceramic coating on bone ingrowth in porous titanium particles

A bone chamber study in goats

, , &
Pages 372-377 | Received 14 Mar 2010, Accepted 08 Feb 2011, Published online: 19 Apr 2011

  • Alffram PA, Bruce L, Bjursten LM, Urban RM, Andersson GB. Implantation of the femoral stem into a bed of titanium granules using vibration: a pilot study of a new method for prothetic fixation in 5 patients followed for up to 15 years. Ups J Med Sci 2007; 112(2):183-9.
  • Aquarius R, Walschot L, Buma P, Schreurs BW, Verdonschot N. In vitro testing of femoral impaction grafting with porous titanium particles: a pilot study. Clin Orthop 2009; (467) (6): 1538-45.
  • Aspenberg P, Tagil M, Kristensson C, Lidin S. Bone graft proteins influence osteoconduction. A titanium chamber study in rats. Acta Orthop Scand 1996; 67(4):377-82.
  • Bolder SB, Verdonschot N, Schreurs BW, Buma P. Acetabular defect reconstruction with impacted morsellized bone grafts or TCP/HA particles. A study on the mechanical stability of cemented cups in an artificial acetabulum model. Biomaterials 2002; 23(3):659-66.
  • Conrad EU, Gretch DR, Obermeyer KR, Moogk MS, Sayers M, Wilson JJ, Strong DM, Transmission of the hepatitis-C virus by tissue transplantation. J Bone Joint Surg (Am) 1995; 77: 214-24.
  • Galea G, Kopman D, Graham BJ. Supply and demand of bone allograft for revision hip surgery in Scotland. J Bone Joint Surg (Br) 1998; 80: 595-9.
  • Gross AE, Goodman S. The current role of structural grafts and cages in revision arthroplasty of the hip. Clin Orthop 2004; (429):193-200.
  • Halliday BR, English HW, Timperley AJ, Gie GA, Ling RS. Femoral impaction grafting with cement in revision total hip replacement. Evolution of the technique and results. J Bone Joint Surg (Br) 2003; 85(6):809-17.
  • Hooten JP Jr, Engh CA, Heekin RD, Vinh TN. Structural bulk allografts in acetabular reconstruction. Analysis of two grafts retrieved at post-mortem. J Bone Joint Surg (Br) 1996; 78(2):270-5.
  • Itälä AI, Ylänen HO, Ekholm C, Karlsson KH, Aro HT. Pore diameter of more than 100 microm is not requisite for bone ingrowth in rabbits. J Biomed Mater Res 2001; 58(6):679-83.
  • Jeppsson C, Astrand J, Tagil M, Aspenberg P. A combination of bisphosphonate and BMP additives in impacted bone allografts. Acta Orthop Scand 2003; 74(4):483-9.
  • Mostardi RA, Pentello A, Kovacik MW, Askew MJ. Prosthetic metals have a variable necrotic threshold in human fibroblasts: an in vitro study. J Biomed Mater Res 2002; 59(4):605-10.
  • Nguyen HQ, Deporter DA, Pilliar RM, Valiquette N, Yakubovich R. The effect of sol-gel-formed calcium phosphate coatings on bone ingrowth and osteoconductivity of porous-surfaced Ti alloy implants. Biomaterials 2004; 25(5):865-76.
  • Ninomiya JT, Struve JA, Stelloh CT, Toth JM, Crosby KE. Effects of hydroxyapatite particulate debris on the production of cytokines and proteases in human fibroblasts. J Orthop Res 2001; 19(4):621-8.
  • Oonishi H, Ohashi H, Oonishi H Jr, Kim SC. THA with hydroxyapatite granules at cement-bone interface: 15- to 20-year results. Clin Orthop 2008; (466) (2): 373-9.
  • Tägil M, Aspenberg P. Impaction of cancellous bone grafts impairs osteoconduction in titanium chambers. Clin Orthop 1998; (352):231-8.
  • Tägil M, Aspenberg P. Fibrous tissue armoring increases the mechanical strength of an impacted bone graft. Acta Orthop Scand 2001; 72(1):78-82.
  • Teller M, Gopp U, Neumann HG, Kühn KD. Release of gentamicin from bone regenerative materials: an in vitro study. J Biomed Mater Res B Appl Biomater 2007; 81(1):23-9.
  • Turner TM, Urban RM, Hall DJ, Andersson GB. Bone ingrowth through porous titanium granulate around a femoral stem: histological assessment in a six-month canine hemiarthroplasty model. Ups J Med Sci 2007; 112(2):191-7.
  • Van der Donk S, Buma P, Slooff TJ, Gardeniers JW, Schreurs BW. Incorporation of morselized bone grafts: a study of 24 acetabular biopsy specimens. Clin Orthop 2002; (396):131-41.
  • Van Haaren EH, Smit TH, Phipps K, Wuisman PI, Blunn G, Heyligers IC. Tricalcium-phosphate and hydroxyapatite bone-graft extender for use in impaction grafting revision surgery. An in vitro study on human femora. J Bone Joint Surg (Br) 2005; 87(2):267-71.
  • Walschot LH, Schreurs BW, Buma P, Verdonschot N. Impactability and time dependent mechanical properties of porous titanium particles for application in impaction grafting. J Biomed Mater Res B Appl Biomater 2010; 95(1):131-40.
  • Warashina H, Sakano S, Kitamura S, Yamauchi KI, Yamaguchi J, Ishiguro N, Hasegawa Y. Biological reaction to alumina, zirconia, titanium and polyethylene particles implanted onto murine calvaria. Biomaterials 2003; 24(21):3655-61.