- Bieger R, Martini F, Reichel H, Decking R. Changes of periprosthetic bone density after implantation of an anatomical femoral stem with cemented and cementless fixation. Hip Int 2011; 21 (3): 317-24.
- Christie MJ, DeBoer DK, Trick LW, Brothers JC, Jones RE, Vise GT, Gruen TA. Primary total hip arthroplasty with use of the modular S-ROM prosthesis. J Bone Joint Surg (Am) 1999; 81 (12): 1707-16.
- Decking R, Puhl W, Simon U, Claes L. Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems. Clin Biomech 2006; 21 (5): 495-501.
- Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orhop 1979; (141): 17-27.
- Mallory TH, Head WC, Lombardi AV, Emerson RH, Eberle RW, Mitchell MB. Clinical and radiographic outcome of a cementless, titanium, plasma spray-coated total hip arthroplasty femoral component. Justification for continuance of use. J Arthroplasty 1996; 11 (6): 653-60.
- National Joint Registry of England, Wales and Northern Ireland, 10th Annual Report 2013, http://www.njrcentre.org.uk.
- Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gibbons CL, Ostlere S, Athanasou N, Gill HS, Murray DW. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg (Br) 2008; 90 (7): 847-51.
- Roorda LD, Jones CA, Waltz M, Lankhorst GJ, Bouter LM, van der Eijken JW, Willems WJ, Heyligers IC, Voaklander DC, Kelly KD, Suarez-Almazor ME. Satisfactory cross cultural equivalence of the Dutch WOMAC in patients with hip osteoarthritis waiting for arthroplasty. Ann Rheum Dis 2004; 63 (1): 36-42.
- Sinha RK, Dungy DS, Yeon HB. Primary total hip arthroplasty with a proximally porous-coated femoral stem. J Bone Joint Surg (Am) 2004; 86 (6): 1254-61.
- Wal van der B CH, Vischjager M, Grimm B, Heyligers IC, Tonino AJ. Periprosthetic fractures around cementless hydroxyapatite-coated femoral stems. Int Orthop 2005; 29 (4): 235-40.
- Wittenberg RH, Steffen R, Windhagen H, Bucking P, Wilcke A. Five-year results of a cementless short-hip-stem prosthesis. Orthop Rev 2013; 5 (1): e4.
- Wu CC, Au MK, Wu SS, Lin LC. Risk factors for postoperative femoral fracture in cementless hip arthroplasty. J Formos Med Assoc 1999; 98 (3): 190-4.
Acta Orthopaedica
Volume 85, 2014 - Issue 4
Open access
783
Views
1
CrossRef citations to date
0
Altmetric
Hip and pelvis
Poor intermediate-term survival of the uncemented Optan anatomically adapted femoral component
A retrospective study of 432 patients with a mean follow-up of 5 years
Luc J M HeijnensClinical Orthopaedic Research Center – midden Nederland (CORC-mN),
Department of Orthopaedics, Diakonessenhuis Hospital Utrecht/Zeist, Utrecht, the Netherlands.
, Jelle J HalmaClinical Orthopaedic Research Center – midden Nederland (CORC-mN),
Department of Orthopaedics, Diakonessenhuis Hospital Utrecht/Zeist, Utrecht, the Netherlands.Correspondence[email protected]
, Steven M van GaalenClinical Orthopaedic Research Center – midden Nederland (CORC-mN),
Department of Orthopaedics, Diakonessenhuis Hospital Utrecht/Zeist, Utrecht, the Netherlands.
& Arthur de GastClinical Orthopaedic Research Center – midden Nederland (CORC-mN),
Department of Orthopaedics, Diakonessenhuis Hospital Utrecht/Zeist, Utrecht, the Netherlands.
Pages 363-367
|
Received 22 Oct 2013, Accepted 25 Mar 2014, Published online: 23 Jun 2014
Related research
People also read lists articles that other readers of this article have read.
Recommended articles lists articles that we recommend and is powered by our AI driven recommendation engine.
Cited by lists all citing articles based on Crossref citations.
Articles with the Crossref icon will open in a new tab.