References
- Bialik V, Rosenberg N. Transfer of greater trochanter. J Pe-diatr Orthop (B) 1994; 3: 30–4
- Böstman O M. Absorbable implants for the fixation of the fractures. J Bone Joint Surg (Am) 1991; 73: 148–53
- Böstman O M, Mäkelä E A, Törmälä P, Rokkanen P. Trans-physeal fracture fixation using biodegradable pins. J Bone Joint Surg (Br) 1989; 71: 706–7
- Bøstman O M, Pihlajamäki H K, Partio E K, Rokkanen P U. Clinical biocompatibility and degradation of polylevolac-tide screws in the ankle. Clin Orthop 1995; 320: 101–9
- Donigian A M, Plaga B R, Caskey P M. Biodegradable fixation of physeal fractures in goat distal femur. J Pediatr Orthop 1993; 13: 349–54
- Gage J R, Cary J M. The effects of trochanteric epiphyseo-desis on growth of the proximal end of the femur following necrosis of the capital femoral epiphysis. J Bone Joint Surg (Am) 1980; 62: 785–94
- Garcés G L, Mugica Garay Y, Gonzalez Lopez, Coviella N, Guerado E. Growth plate modifications after drilling. J Pediatr Orthop 1994; 14: 225–8
- Hope P G, Williamson D M, Coates C J, Cole W G. Biodegradable pin fixation of elbow fractures in children. J Bone Joint Surg (Br) 1991; 73: 965–8
- Langenskiold A. The possibilities of eliminating premature partial closure of an epiphyseal plate caused by trauma or disease. Acta Orthop Scand 1967; 38: 267–79
- Langenskiöld A, Salenius P. Epiphyseodesis of the greater trochanter. Acta Orthop Scand 1967; 38: 199–219
- Lee E H, Gao G X, Bose K. Management of partial growth arrest: physis, fat or silastic?. J Pediatr Orthop 1993; 13: 368–72
- Lloyd-Roberts G C, Wetherill M H, Fraser M. Trochanteric advancement for premature arrest of the femoral capital growth plate. J Bone Joint Surg (Br) 1985; 67: 21–4
- Macnicol M F, Makris D. Distal transfer of the greater trochanter. J Bone Joint Surg (Br) 1991; 73: 838–41
- Mäkelä E A, Vainionpää S, Vihtonen K, Mero M, Helevirta P, Törmälä P, Rokkanen P. The effect of a penetrating biodegradable implant on the growth plate. An experimental study on growing rabbits with special reference to poly-dioxanone. Clin Orthop 1989; 241: 300–8
- Mäkelä E A, Böstman O M, Kekomäki M, Södergård J, Vainio J, Törmälä P, Rokkanen P. Biodegradable fixation of distal humeral physeal fractures. Clin Orthop 1992; 283: 237–43
- Otsuka N, Man J Y, Orr F W, Martin R F. Biodegradation of polydioxanone in bone tissue: effect on the epiphyseal plate in immature rabbits. J Pediatr Orthop 1992; 12: 177–80
- Pihlajamäki H, Böstman O M, Manninen M, Päivärinta U, Törmälä P, Rokkanen P. Absorbable plugs of self-reinforced poly-L-lactic acid for fixation of fractures and osteotomies. J Bone Joint Surg (Br) 1992; 74: 853–7
- Siffert R S. The effect of staples and longitudinal wires on epiphyseal growth. An experimental study. J Bone Joint Surg (Am) 1956; 38: 1077–88
- Siffert R S. The growth plate and its affections. J Bone Joint Surg (Am) 1966; 48: 546–63
- Sinisaari I, Pätiälä H, Böstman O M, Mäkelä E A, Hirvensa-Lo E, Partio E K, Törmälä P, Rokkanen P. Metallic or absorbable for ankle fractures. A comparative study of infection in 3111 cases. Acta Orthop Scand 1996; 67: 16–8
- Stadelmaier D M, Arnoczky S P, Dodds J, Ross H. The effect of drilling and soft tissue grafting across open growth plates. A histologic study. Am J Sports Med 1995; 23: 431–5
- Stevens P M, Coleman S S. Coxa breva: Its pathogenesis and a rationale for its management. J Pediatr Orthop 1985; 5: 515–21
- Strobino L J, Colonna P C, Brodey R S, Leinbach T. The effect of compression on the growth of epiphyseal bone. Surg Gyn Obst 1956; 103: 85–93
- Tauber C, Ganel A, Horoszowski H, Farine Y. Distal transfer of the greater trochanter in coxa vara. Acta Orthop Scand 1980; 51: 661–6