3,298
Views
16
CrossRef citations to date
0
Altmetric
Research Article

An amperometric biosensor for glucose detection from glucose oxidase immobilized in polyaniline–polyvinylsulfonate–potassium ferricyanide film

&
Pages 284-288 | Received 24 Apr 2013, Accepted 04 Jun 2013, Published online: 03 Jul 2013

References

  • Arslan F, Ustabas S, Arslan H. 2011. An amperometric biosensor for glucose determination prepared from glucose oxidase immobilized in polyaniline-polyvinylsulfonate film. Sensors. 11:8152–8153.
  • Arslan F, Yasar A, Kiliç E. 2006. Preparation of Pt/Polypyrrole– Ferrocene hydrogen peroxide sensitive electrode for the use as a biosensor. Russ J Electrochem. 42:137–140.
  • Arslan H, Özdemir M, Zengin H, Zengin G. 2012. Glucose biosensing at carbon paste electrodes containing polyaniline-silicon dioxide composite. Int J Electrochem Sci. 7:10205–10214.
  • Barlett PN, Cooper JM. 1993. A review of the immobilization of enzymes in electropolymerized films. J Electroanal Chem. 362:1–12.
  • Bidan G. 1992. Electroconducting conjugated polymers: new sensitive matrices to build up chemical or electrochemical sensors. Sens Actuators B. 6:45–56.
  • Chaubey A, Malhotra BD. 2002. Review: mediated biosensors. Biosens Bioelectron. 17:441–456.
  • Chen C, Jiang Y, Kan J. 2006. A noninterference polypyrrole glucose biosensor. Biosens Bioelectron. 22:639–643.
  • Colak O, Arslan H, Zengin H, Zengin G. 2012. Amperometric detection of glucose by polyaniline-activated carbon composite carbon paste electrode. Int J Electrochem Sci. 7:6988–6997.
  • Cosiner S. 1999. Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review. Biosens Bioelectron. 14:443–456.
  • Gaikwad PD, Savale PA, Shirale DJ, Kharat HJ, Kakde KP, Gade VK, Shirsat MD. 2005. Effect of electrolyte on optical properties of potentiostatic electro-deposited conducting polymer films for biosensor applications. Microwaves and Optoelectronics. UK: Anshan Ltd, Tunbridge Wells, pp. 450–454.
  • Gaikwad PD, Shirale DJ, Savale PA, Datta K, Ghosh P, Shirsat MD. 2007. Development of PANI-PVS-GOD electrode by potentiometric method for determination of glucose. Int J Electrochem Sci. 2: 488–497.
  • Garcia CAB, Neto GO, Kubota LT. 1998. New fructose biosensors utilizing a polypyrrole film and D-fructose 5-dehydrogenase immobilized by different processes. Anal Chim Acta. 374:201–208.
  • Ghica ME, Brett CM. 2005. A glucose biosensor using methyl viologen redox mediator on carbon film electrodes. Anal Chim Acta. 532: 145–151.
  • Gros P, Durliat H, Comtat M. 2000. Use of polypyrrole film containing Fe(CN)63− as pseudo-reference electrode: application for amperometric biosensors. Electrochim Acta. 46:643–650.
  • Norouzi P, Faridbod F, Larijani B, Ganjali MR. 2010. Glucose biosensor based on MWCNTs-Gold nanoparticles in a nafion film on the glassy carbon electrode using flow injection FFT continuous cyclic voltammetry. Int J Electrochem Sci. 5:1213–1224.
  • Pate H, Li X, Karana HI. 2003. Amperometric glucose sensors based on ferrocene containing polymeric electron transfer systems. Biosens Bioelectron. 18:1073–1076.
  • Ricci F, Palleschi G. 2005. Review: sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes. Biosens Bioelectron. 21:389–407.
  • Shan D, Wang S, He Y, Xue H. 2008. Amperometric glucose biosensor based on in situ electropolymerized polyaniline/poly (acrylonitrile-co-acrylic acid) composite film. Mater Sci Eng C. 28:213–217.
  • Shi Q, Wang P, Jiang Y, Kan J. 2009. Glucose biosensor based on polyaniline synthesized in ionic liquid. Biocatal Biotransformation. 27:54–59.
  • Shirale DJ, Bhalerao AS, Kharat HJ, Gaikwad PD, Kakde KP, Savale PA, Gade VK, Shirsat MD. 2005. Influence of pH on optical properties of conducting polyaniline film for biosensor applications. In: Shirsat MD, Ed. Microwaves and Optoelectronics. UK: Anshan Ltd, Tunbridge Wells, pp. 455–458.
  • Wu B, Zhang G, Shuang S, Choi MM. 2004. Biosensors for determination of glucose with glucose oxidase immobilized on an eggshell membrane. Talanta. 64:546–553.
  • Xue H, Shen Z, Li Y. 2001. Polyaniline-polyisoprene composite film based glucose biosensor with high permselectivity. Synthetic Metals. 124:345–349.
  • Xue H, Shen Z, Li C. 2005. Improved selectivity and stability of glucose biosensor based on in situ electropolymerized polyaniline-polyacrylonitrile composite film. Biosens Bioelectron. 20:2330–2334.
  • Zhang Y, Wen G, Zhou Y, Shuang S, Dong C, Choi MM. 2007. Development and analytical application of an uric acid biosensor using an uricase-immobilized eggshell membrane. Biosens Bioelectron. 22:1791–1797.
  • Zhao H, Yuan Y, Adelojue S, Wallace GG. 2002. Study on the formation of the Prussian blue films on the polypyrrole surface as a potential mediator system for biosensing applications. Anal Chim Acta. 472:113–121.
  • Zhou H, Chen H, Luo S, Chen J, Wei W. 2005. Glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline. Biosens Bioelectron. 20:1305–1311.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.