57
Views
0
CrossRef citations to date
0
Altmetric
Original Articles

Prognostic significance of improvement in right ventricular systolic function during cardiac resynchronization therapy

, MD, , MD, PhD, , MD, , MD, , MD, , MD, , MD, PhD, , MD, PhD & , MD, PhD show all
Pages 267-275 | Received 23 Mar 2016, Accepted 09 May 2016, Published online: 31 Mar 2017
 

Abstract

Objectives There is conflicting evidence concerning the role of right ventricular (RV) systolic dysfunction in the long-term clinical outcome after cardiac resynchronization therapy (CRT). Therefore we aimed to assess evolution of RV systolic function during CRT, covariates associated with its improvement, and its impact on outcome.

Methods and results All CRT device implantations (Jan 2009-Dec 2011) in our institution were reviewed. Records of 69 patients (25% female, mean age 62.8 ± 9.2 years, mean left ventricular (LV) ejection fraction 27 ± 8%) were analyzed. Baseline RV fractional area change (FAC) < 35% was present in 37 patients (54%). At one year, 24 of them (65%) improved in RV FAC. LV remodeling and mitral regurgitation were significantly associated with the likelihood of RV FAC improvement (OR 4.80, 95% CI 1.13-20.46, P = 0.034 and OR 0.32, 95% CI 0.12-0.89, P = 0.029, respectively). The composite endpoint of death or heart transplantation occurred in 23 patients (33%) over a mean follow-up of 2.8 ± 1.4 years. RV FAC at one year (HR 0.90, 95% CI 0.86-0.94, P < .001) was, independently of NYHA class and LV remodeling, associated with clinical outcome.

Conclusions RV systolic function might improve during CRT. This seems mainly due to changed left-sided hemodynamics and LV remodeling. Good RV systolic function is independently related with better outcome.

CONFLICT OF INTEREST

Rik Willems receives unconditional research funding from Biotronik, Boston Scientific Belgium and Medtronic Belgium, and has received speakers and consultancy fees from and participated in clinical trials by different manufactures of cardiac implantable electronic devices (Medtronic, Boston Scientific, Biotronik, St Jude Medical, Sorin). All other authors have no conflicts of interest to declare.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.