Does a Foamy-Block Mattress System Prevent Pressure Sores ? A Prospective Randomised Clinical Trial in 1729 Patients

, , &
Pages 155-161 | Published online: 11 Mar 2016
 

Abstract

Background: Pressure ulcers are a frequent complication of bed rest. The development of an efficient and low cost pressure relieving system for the prevention of bed-sores would be of considerable hospital health and economic interest. Our study was designed to determine the effectiveness in pressure-sore prevention of an interface pressure-decreasing mattress, the Kliniplot® mattress, used in our institution since 1978.

Methods: In a prospective randomised controlled 7-month clinical trial we compared the Kliniplot® mattress with our standard hospital mattress in 1729 patients admitted to medical and surgical departments (neurology, cardiology, oncology-haematology, neurosurgery, thoracic surgery and orthopaedic surgery). Two groups (Klinipot® mattress and standard hospital mattress) were monitored for the prevention of pressure sores. The patients were evaluated on a daily basis from their admission until the eventual occurrence of a bed-sore. Patients’ characteristics and pressure-sore risk factors were similar at the baseline in both groups. Patients presenting with a pressure sore at the time of admission were excluded.

Results: Forty-two of the 1729 patients (2.4%) who entered the study developed at least one pressure sore. Twenty-one of the 657 patients (3.2%) nursed on the Kliniplot® mattress, and 21 of the 1072 patients (1.9%) on the standard mattress developed bed-sores (p = 0.154). The median time for the occurrence of pressure sores was 31 days (range 687) with the Kliniplot® mattress and 18 days (range 2 to 38) with the standard mattress (p < 0.001). The risk categories for developing bed-sores using the modified Ek’s scale were no different at the baseline between both groups (p = 0.764). The severity of the pressure sores was no different between both groups (p = 0.918).

Conclusions: Our results show that the occurrence of pressure sores is not reduced but is delayed when patients are nursed on a Kliniplot® pressure-decreasing mattress.

Additional information

Notes on contributors

J.-V. Berthe

J.-V. Berthe, M.D. Department of Plastic and Reconstructive Surgery Erasme University Hospital 808, Route de Lennik B-1070 Brussels, Belgium Tel.: 32-2-555.45.50 Fax: 32-2-555.45.96 E-mail: [email protected]

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.