199
Views
27
CrossRef citations to date
0
Altmetric
ORIGINAL ARTICLE

Comparisons between Neural Response Imaging thresholds, electrically evoked auditory reflex thresholds and most comfortable loudness levels in CII Bionic Ear users with HiResolution™ sound processing strategies

, , MD, , , , , & show all
Pages 732-735 | Received 24 Aug 2004, Published online: 08 Jul 2009
 

Abstract

Conclusions. The data collected in this study indicated that first Neural Response Imaging (NRI) thresholds had a better correlation with HiResolution™ most comfortable loudness (M) levels than tNRI thresholds. Electrically evoked auditory reflex thresholds (EARTs) had a higher correlation with HiResolution M levels than tNRI thresholds and a lower correlation than first NRI thresholds. NRI is a very useful method for programming the cochlear implants of young children who cannot demonstrate a reliable judgment of loudness. Objective. To investigate how HiResolution sound processing, designed to deliver high-rate stimuli, relates to EARTs and electrically evoked compound action potential measurements produced by low-rate stimuli. Material and methods. Nine profoundly hearing-impaired children and adults aged 6–29 years participated in the study. NRI responses were elicited using pulse trains consisting of biphasic pulses at a pulse width per phase of 32 µs delivered at a frequency of 30 Hz using SoundWave programming software. Stimuli were delivered to the odd electrodes (1, 3, 5, 7, 9, 11, 13 and 15) along the array. tNRI (NRI threshold) and first NRI thresholds were recorded for each stimulating electrode. “Speech bursts” stimuli used in EARTs recording were delivered to four electrodes at a time and stapedial reflexes were recorded from the impedance bridge. The M levels used were those used by each patient in their everyday HiResolution programs. Results. For 8 patients (53 stimulating electrodes) the correlation between tNRI threshold and M level was r = 0.675 (p = 0.000) and that between first NRI thresholds and M level was r=0.741 (p = 0.000). On average the M-level value was 20 CU (Current Unit) lower than the first NRI threshold value and 12 CU higher than the tNRI threshold value. The M-level patterns across the electrode array overall were similar to the tNRI or first NRI threshold patterns. For 7 patients (112 stimulating electrodes) the correlation between EART and M levels was r=0.710 (p = 0.000). On average the EART value was 14 CU higher than the M-level value.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.