Abstract
This paper reports on the plume rise research project conducted by TVA under sponsorship of the U. S. Public Health Service. Plume rise data were collected at six coal-fired, steam-electric generating stations within the TVA system over a 2-year period. Unit ratings ranged from 173 to 704 Mw with stack heights varying from 250 to 600 ft. An instrumented helicopter and special photographic equipment were used to obtain 1580 separate plume observations and significant related meteorological parameters during stable, neutral, and slightly unstable conditions. The 1580 observations were resolved and consolidated into 133 composite observation periods covering 30 to 120 min. Meteorological parameters and other compiled input data were entered into four principal equations for calculation of plume rise, and calculated plume rise values were compared with observed values. Most equations overestimated plume rise in low wind speed. For moderately high wind speeds, the Carson and Moses and the Concawe equations gave best fit.