Abstract
Although polarized electrostatic air filters are efficient air filtrating devices, their main disadvantages are difficulty in collecting conductive particles or in operating at relative humidities above 70%. We describe here a new filter design that eliminates these problems. A nonconductive media, normally a glass fiber mat, is placed between two insulated conductive screens. As the voltage across the screens is increased, the penetration of particles decreases exponentially. Increasing the electric field from 0 to 10 kV/cm will decrease the mass penetration from 60% to less than 10% of a polydispersed 0.8 µm ammd (σg = 2.0) sodium chloride aerosol. The experimental effects of face velocity, particle charge and size, packing density, fiber size, and screen insulation mirror the theoretical effects of these variables on particle penetration.