Determination of Orciprenaline Using a Flow Injection Analysis System with Sequential Potentiometric and Spectrophotometric Detection

Pages 949-964 | Received 06 Dec 2007, Accepted 05 Jan 2008, Published online: 05 Jun 2008
 

Abstract

This work describes an attempt to have a flow injection analysis (FIA) system for Orciprenaline with potentiometric and spectrophotometric detectors working sequentially. The potentiometric detection was performed using an orciprenaline ion-selective electrode made of orciprenaline ion-associate with phosphotungstic acid incorporated in a PVC matrix membrane, followed by sequential spectrophotometric detection of the same sample using the reaction of orciprenaline with phosphomolybdic acid in alkaline medium and measurement at 670 nm using a USB2000 fiber-optic spectrophotometer. The method was applied and validated for the assay of different samples that are 1.0 × 10−2–1.0 × 10−7 M orciprenaline, and the recovery values for Alupent® tablets, plasma and urine sample ranged from 99.39–100.93, 99.87–100.57, and 98.83–100.64 respectively for the potentiometric detector and 99.66–100.58, 99.78–100.69 and 99.12–100.92 respectively for the sequential spectrophotometric detector. It was found that using the double detection system compensated for both the unselectivity of the spectrophotometric method and the low detection limit of the potentiometric method (6.3 × 10−4 M). Although two detectors were used in the measurements, the method is still very simple to design and apply, in addition to being rapid and less expensive than other more sophisticated techniques applied in the literature and can therefore be used for other pharmaceutical compounds as well.

Notes

Detector A: potentiometric detection.

Detector B: spectrophotometric detection.

RSD: four determinations.

S.E.: error relative to the taken value.

t-value: value of t-test application at confidence limit 99%.

∗Detector A: potentiometric detection.

∗∗Detector B: spectrophotometric detection

a Found vs. theoretical.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.