Validation of a Method for the Determination of Total Chromium in Rat Feces by Inductively Coupled Plasma Optical Emission Spectrometry

, , , , , , , & show all
Pages 2729-2746 | Received 17 Sep 2008, Accepted 05 Jan 2009, Published online: 02 Nov 2009
 

Abstract

The validation of a method for the determination of total chromium in Fischer-344 rat feces by inductively coupled plasma optical emission spectrometry following a rapid, atmospheric-pressure microwave digestion is described. The performance of the method was evaluated over the concentration range of 5.00 to 200 µg Cr/g feces. Data for method linearity, accuracy, precision, digest stability, and storage stability are presented along with limit of detection and limit of quantitation data. Data from a cross-validation method for B6C3F1 mouse feces are also presented. Following validation, the method was applied to analyze samples collected in support of two chronic toxicological investigations.

The analytical work was funded in full by the National Institute of Environmental Health Sciences, National Institute of Health, Contract Numbers N01-ES-05455 and N01-ES-65554.

Notes

a Nominal Cr concentration in final analysis solution.

b Calculated as (concentration of Cr (µg/mL) × 25-mL digest volume)/nominal 0.250-g wet tissue mass.

a Internal standard corrected emission intensity for matrix and solvent standards.

b Calculated with matrix regression equation: y = 0.09368(x) + 0.003240; r = 0.9992.

c Calculated as (mean found [Cr] (µg/mL)/nominal [Cr] (µg/mL)) × 100.

d Calculated as (mean blank corrected matrix response/blank corrected solvent response) × 100. Mean matrix blank response = 0.002600; solvent blank response= −0.0006811.

e Calculated as (concentration of Cr (µg/mL) × 25-mL digest volume)/nominal 0.250-g wet tissue mass.

a Calculated as (mean found [Cr] (µg/g)/nominal [Cr] (µg/g)) × 100.

a Calculated as (mean found [Cr] (µg/mL)/mean reference [Cr] (µg/mL)) × 100.

a Mean recovery for three preparations calculated against mean reference concentration.

b Not applicable; two of three replicates lost during sample preparation.

a Internal standard corrected emission intensity for matrix and solvent standards.

b Calculated with matrix regression equation y = 0.09368(x) + 0.003240; r = 0.9992.

c Calculated as (mean found [Cr] (µg/mL)/nominal [Cr] (µg/mL)) × 100.

d Calculated as (mean blank corrected matrix response/blank corrected solvent response) × 100. Mean matrix blank response = 0.01093; solvent blank response = 0.001610.

e Calculated as [concentration of Cr (µg/mL) × 25-mL digest volume]/nominal 0.250-g wet tissue mass.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.