25
Views
9
CrossRef citations to date
0
Altmetric
ENVIRONMENTAL ANALYSIS

A Sampling and Analytical Method for Ethylene Glycol in Air

&
Pages 959-976 | Received 27 Apr 1981, Accepted 08 Jun 1981, Published online: 06 Dec 2006
 

Abstract

A personal sampling and analytical method for ethylene glycol aerosol and vapor in air was developed and tested. The personal sampler contains a glass fiber filter followed by two sections of silica gel. Samples are analyzed by gas chromatography. Ethylene glycol vapor at concentrations ranging from 4.2 to 327 mg/m3 for 3-L air samples can be measured. Ethylene glycol can evaporate from the filter during air sampling at 25 °C and enter the silica gel tube.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.